Page 2 - Pre-Installation Suggestions; COMPONENTS
Table Of Contents Page 2 Wiring Diagram Page 3 Installation Tips Page 4 Pre-Installation Suggestions Installation Suggestions Mounting The ModuleInstalling The LEDInstalling The Program ButtonUnder Hood ConnectionsMounting The Siren Wire Connectors Page 5 14 Pin Main Harness Connector4 Pin Red Conne...
Page 3 - WIRING DIAGRAM
Blue Connect to hood and / or trunk pin Hood Input Green Connect to door pin. (-) when opened Door Input Purple Connect to door pin. (+) when opened Door Input Black Connect to chassis ground Ground Input Brown Connect to Siren wire. 2amp Maximum Siren Output Red Connect to constant power. 20amp inp...
Page 4 - Programmable; Pin Connector Red; Under Hood Connections-
Recommended Installation Procedures White (+) Park lights Park light output. Orange (-) When Armed Negative output when system is armed. Grey (-) Trunk Release Negative output for trunk release. 500ma max. Yellow Ignition Input Input from vehicles ignition wire. RedMain Power Input Constant 12 Volt ...
Page 5 - Do not set to sensitive.; BASIC INSTALLATION
10 Pin Power Connector Step 2- Plug-In The Module Step 3- Test And Adjust The Shock Sensor Your Basic Install Is Complete! Step 4- Test The System Step 1 - Connect All Of the Following Wires When all the connections are done, the control module can be plugged in. Beforeconnecting the control module,...
Page 6 - PROGRAM OVERVIEW; Entering Program Mode; Active
Program mode allows you to adjust the settings and options of your system. Your systemhas been intelligently designed by installers with years of experience. The system’s defaultsettings do not require any program changes in most cases. However, this system doesincorporate a advanced programming sys...
Page 7 - Passive / Active Ar ming
Entering program mode is done by the following steps: 1) Make sure ignition is in the off position.2) Turn the ignition key ON - OFF, leaving key in the OFF position. 3) Press and release the Valet button two times.4) The siren will chirp one time to confirm entering program mode. ( If this does not...
Page 8 - Voltage / Door Pin Sensing; Repeat sequence to change selection
To change settings:1 - Enter Program Mode - (Ignition ON-OFF, followed by Valet 2 times) 2 - Press & release transmitter buttons in the following sequence #1 - #1 then #33 - The siren will respond with the following: 1 Chirp Voltage Sensing- No Door Pin Connection Needed 2 Chirps Door Pin- Door ...
Page 9 - Exit; Exit; Basic Transmitter Functions
- Press and release to arm the alarm and lock the doors. - Press and hold to activate Panic mode. - Press and release to deactivate triggered alarm. - Press and release to disarm and unlock the doors . - Press and hold to activate the Trunk Release. - Press and release to deactivate triggered alarm....
Page 10 - PANIC MODE DISABLE
1.Press and hold the UNLOCK button for three seconds. 2.The doors will unlock, continue holding the unlock button three seconds. theTrunk release will then activate. The trunk release will be confirmed by onepark light flash.3.For safety reasons, the trunk release output will not activate when ignit...
Page 12 - Negative Park Lights-; In some cases the park lights may flash erratically after; White; Negative park light output
87 86 85 87a 30 87 86 85 87a 30 87 86 85 87a 30 87 86 85 87a 30 87 86 85 87a 30 Negative Type Door Locks Positive Type Door Locks 5 Wire / Reverse Polarity Type Door Locks Negative Park Lights- In some cases the park lights may flash erratically after installing the negative park light relay. To cor...