Page 2 - Table of Contents; Safety
USER GUIDE & SERVICE MANUAL u-line.com Table of Contents Intro Safety Safety and Warning Disposal And Recycling Installation Environmental Requirements Electrical Cutout & Product Dimensions Side by Side Installation Anti-Tip Bracket General Installation Grille Installation Door Swing Interi...
Page 3 - USER GUIDE; clean integrated look allow you; PRODUCT INFORMATION; Designed, engineered and assembled in WI, USA
USER GUIDE u-line.com Introduction WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades of premium modular ice making, refrigeration, and wine preservation experience. U-Line creates products focused on functionality, style, and inspired...
Page 4 - Safety and Warning; SAFETY ALERT DEFINITIONS; DANGER
USER GUIDE u-line.com Safety and Warning Safety and Warning NOTICEPlease read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide: SAFETY ALERT DEFINIT...
Page 5 - Disposal and Recycling; Remove all consumable contents from the unit.
USER GUIDE u-line.com Disposal and Recycling Disposal and Recycling RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal, check a...
Page 6 - Environmental Requirements; CAUTION
USER GUIDE Environmental Requirements u-line.com Environmental Requirements This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models. For best performan...
Page 7 - Electrical; WARNING; Always keep your working area dry.
USER GUIDE Electrical u-line.com Electrical WARNING ! SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter...
Page 8 - Cutout & Product Dimensions; *15” cutout width sufficient if door protrudes beyond
USER GUIDE Cutout & Product Dimensions u-line.com Cutout & Product Dimensions PREPARE SITE Your U-Line product has been designed for either free-standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grill...
Page 9 - Slide both units out so screws on top of units are easily
USER GUIDE Side-by-Side Installation u-line.com Side-by-Side Installation Two units may be installed side-by-side. Cutout width for a side-by-side installation is the cutout dimension of a single unit times two. No trim kit is required. However, 1/4" (6 mm) of space needs to be maintained betwee...
Page 11 - General Installation; LEVELING INFORMATION; Turn to Adjust
USER GUIDE u-line.com General Installation General Installation LEVELING INFORMATION 1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not level, adjust the legs on the corners of the unit as necessary. 3. Confirm the unit is...
Page 12 - Grille Installation; REMOVING AND INSTALLING GRILLE; When using the unit, the grille must be installed.; hinge and slide grille behind hinge.
USER GUIDE Grille Installation u-line.com Grille Installation REMOVING AND INSTALLING GRILLE WARNING ! Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. Removing the grille 1. Disconnect power to the unit. 2. Remove three screws (1)....
Page 13 - Door Swing
USER GUIDE Door Swing u-line.com Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless Steel models require 2-1/8" (54 mm) door clearance to accommodate the handle if installed next to a wall. Wall 90° Door Swing 2-1/8" Min. (54 mm) 1...
Page 14 - First Use; NOTICE
USER GUIDE First Use u-line.com First Use Initial startup requires no adjustments. If the unit was turned off, press and hold for 5 seconds to turn unit on. See “Control Operation” section for more details. NOTICE Temperature displayed reflects actual temperature inside unit. If the temperature disp...
Page 15 - Control Operation; CONTROL FUNCTION GUIDE; SH; DOOR ALERT NOTIFICATION
USER GUIDE u-line.com Control Operation Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and hold down for 5 seconds Unit will turn On or OFF Leave interior light on Press and release to leave interior light on for 3 hours; press again to deactivate After 3 hours, factory...
Page 16 - • Do not block the front grille - no additional clearance; Bottles and cans come in many shapes and sizes. Not; Airflow and Product Loading; Magnum Bottle
USER GUIDE u-line.com Airflow & Product Loading Restricting airflow may result in poor product performance, product failure, and uneven internal temperatures and may freeze contents. • Do not block the front grille - no additional clearance around sides, top or rear of unit is needed for ventila...
Page 17 - Interior Adjustments; INTERIOR SHELVES; Insert the shelves as follows:
USER GUIDE Interior Adjustments u-line.com Interior Adjustments INTERIOR SHELVES Removing and Installing Interior Shelves For models equipped with glass shelves having recessed shelf supports, remove the shelves as follows: 1. Pull shelf out about 6" (1), until back of shelf clears the “hump” on...
Page 18 - Cleaning; Stainless Models
USER GUIDE Cleaning u-line.com Cleaning Stainless Models Stainless door panels and handles can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach. Keep your stainless unit looking new by cleaning with a good quality all-in-one stainless steel cleaner and polish ...
Page 19 - Remove all products from the interior.
USER GUIDE Cleaning u-line.com NOTICE The drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flooring, the unit must be removed from cabinetry. To defrost: 1. Disconnect power to the ...
Page 20 - Cleaning Condenser; INTERVAL - EVERY SIX MONTHS; Clean the condenser coil using a soft brush or vacuum
USER GUIDE u-line.com Cleaning Condenser Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary. WAR...
Page 21 - Remove all consumable content from the unit.; WINTERIZATION
USER GUIDE Extended Non-Use u-line.com Extended Non-Use VACATION/HOLIDAY, PROLONGED SHUTDOWN The following steps are recommended for periods of extended non-use: 1. Remove all consumable content from the unit. 2. Disconnect the power cord from its outlet/socket and leave it disconnected until the un...
Page 22 - Troubleshooting
USER GUIDE u-line.com Troubleshooting u-line.com If you think your U-Line product is malfunctioning, read the CONTROL OPERATION section to clearly understand the function of the control. If the problem persists, read the NORMAL OPERATING SOUNDS and TROUBLESHOOTING GUIDE sections below to help you qu...
Page 23 - CHECKING PRODUCT TEMPERATURE; The time the internal light is illuminated. (This mainly
USER GUIDE u-line.com u-line.com Troubleshooting CHECKING PRODUCT TEMPERATURE To check the actual product temperature in the unit: 1. Partially fill a plastic (nonbreakable) bottle with water. 2. Insert an accurate thermometer. 3. Tighten the bottle cap securely. 4. Place the bottle in the desired a...
Page 24 - Wire Diagram; POWER C
USER GUIDE u-line.com Wire Diagram Wire Diagram 115 V Open Ligh t blue W hit e Black N.C. 1 6 Ev ap/C ond fan Ligh t Ev ap t emp Zone t emp D oor swit ch Compr essor FUSE Prog ramming User I nter fac e 42376_C (If A pplicable) POWER C ORD ASSEMBL Y 220-240 VOL T PL UG LIVE BLA CK (115V ) BR OWN (220...
Page 25 - Product Liability; Right temperature Since 1962.
USER GUIDE u-line.com Product Liability Product Liability Field service technicians are authorized to make an initial assessment in the event of reported damages. If there are any questions about the process involved, the technician should call U-Line for further explanation. While inspecting for de...
Page 26 - Warranty Claims
USER GUIDE u-line.com Warranty Claims The following information defines the parameters for filing a warranty claim: • Valid serial number needed • Valid model number needed • Claims must be submitted online at www.U-LineService.com • 60 day submittal deadline from date of completed service • Only on...
Page 27 - Ordering Replacement Parts; See our contact information below:
USER GUIDE u-line.com Ordering Replacement Parts Ordering Replacement Parts Parts may be ordered online at www.U-Line.com See our contact information below: www.U-LineService.com (with service login)Phone Number: +1.414.354.0300 NOTICEUse only genuine U-Line replacement parts. The use of non-U-Line ...
Page 28 - SERVICE; R-600A Specifications; Gloves and Eye Protection must be used.
USER GUIDE u-line.com R-600A Specifications USER GUIDE R-600A Specifications 1 u-line.com SAFETY • INSTALLATION & IN TEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A Specifications For R-600a refrigerant service tips and more videos, go to: www.u-line.com/videos . WARNING ! Flam...
Page 29 - Ventilation is required during servicing.
R-600A Specifications USER GUIDE u-line.com USER GUIDE R-600A Specifications 2 u-line.com SAFETY • INSTALLATION & IN TEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE WARNING ! Only skilled and well trained service technicians permitted to service R-600a equipped products. All tools and...
Page 30 - SYSTEM REPAIR; Evacuate and charge with dry nitrogen for leak checks.; LEAK DETECTION
USER GUIDE u-line.com R-600A Specifications USER GUIDE R-600A Specifications 3 u-line.com SAFETY • INSTALLATION & IN TEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the system is empty of R-600a before any system work is performed. The...
Page 31 - RECHARGING; Never use a torch on a fully charged refrigeration system.; SUMMARY; R-600a approved service tools must be used.
R-600A Specifications USER GUIDE u-line.com USER GUIDE R-600A Specifications 4 u-line.com SAFETY • INSTALLATION & IN TEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, compressor and suction line) must be leak tested with the compress...
Page 32 - System Diagnosis Guide
USER GUIDE u-line.com System Diagnosis Guide System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Condition Suction Pressure Suction Line Compressor Discharge Condenser Capillary Tube Evaporator Wattage Normal Normal Slightly below room temperature Very hot Very hot Warm Cold Normal Ov...
Page 33 - Compressor Specifications; Disconnect the power source.
USER GUIDE u-line.com Compressor Specifications USER GUIDE Compressor Specifications 1 u-line.com SAFETY • INSTALLATION & IN TEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Compressor Specifications DANGER ! Electrocution can cause death or serious injury. Burns from hot or cold surfa...
Page 34 - Troubleshooting - Extended; SPECIFIC ERRORS AND ISSUES
USER GUIDE u-line.com Troubleshooting Extended Troubleshooting - Extended CAUTION ! Never attempt to repair or perform maintenance on the unit until the main electrical power has been disconnected from the unit. SPECIFIC ERRORS AND ISSUES The advanced diagnostic capabilities of the electronic contro...
Page 35 - TROUBLESHOOTING GUIDE
USER GUIDE u-line.com Troubleshooting Extended TROUBLESHOOTING GUIDE Concern Potential Causes Action Not Cooling Compressor overheating Verify proper air flow through condenser. Is condenser clean?Confirm condenser fan operation. Compressor not operating Test overload and relay, replace as needed. C...
Page 36 - MAIN CONTROL; PLUNGER SWITCH
USER GUIDE u-line.com Troubleshooting Extended MAIN CONTROL The main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose the board for any suspected failures before attempting to remove the board for replacement or service. Follow the guidelines b...
Page 37 - Control Operation-Service; Defrost Duration
USER GUIDE u-line.com Control Operation-Service Control Operation-Service UI BUTTON LAYOUT 1. Up Button 2. Down Button 3. Light Button -Increases temperature-Navigates through service menu-LED activated with button activation -Decreases temperature-Navigates through service menu-LED activated with b...
Page 38 - Thermistor Resistance Data; verified. Place the thermistor in an ice water bath, the; one; If the zone thermistor in the unit fails, the unit will; Thermistor
USER GUIDE u-line.com Thermistor Thermistor Resistance Data Thermistors Thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a resistance which varies based on surrounding temperatures. If a faulty thermistor is suspected it may be tested usi...
Page 39 - Defrost; Control Operation - Service
USER GUIDE u-line.com Defrost Defrost Outdoor units defrost every 12 hours of compressor runtime for 45 minutes. If you have verified that the unit does not have an ambient air leak, utilize the Control Operation - Service section and adjust unit to defrost every 9 hours for 60 minutes 39
Page 40 - Remove Fan and Cover; CONVECTION COOLING; cools product faster and increases energy efficiency.; Evaporator Fan; be modified through the service menu.; Evaporator Fan Replacement; Evaporator Cover
USER GUIDE u-line.com Remove Fan and Cover Remove Fan and Cover CONVECTION COOLING This unit is equipped with an advanced convection cooling system. Convection cooling stabilizes cabinet temperature, cools product faster and increases energy efficiency. Evaporator Fan The evaporator fan is responsib...
Page 42 - One Year Limited Warranty
Copyright © 20 20 U-Line Corporation. All Rights Reserved. | Publication Number 30379 | 1 1 /20 20 Rev. O U-Line Corporation (U-Line) Limited Warranty One Year Limited Warranty For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of ...