Page 2 - Table of Contents; Safety
USER GUIDE & SERVICE MANUAL u-line.com Table of Contents Intro Safety Safety and Warning Disposal And Recycling Installation Environmental Requirements Electrical Cutout & Product Dimensions Side by Side Installation Water Hookup Drain Drain Pump General Installation Grille Installation Door...
Page 3 - USER GUIDE; clean integrated look allow you; PRODUCT INFORMATION; Designed, engineered and assembled in WI, USA
USER GUIDE u-line.com Introduction WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades of premium modular ice making, refrigeration, and wine preservation experience. U-Line creates products focused on functionality, style, and inspired...
Page 4 - Safety and Warning; SAFETY ALERT DEFINITIONS; DANGER
USER GUIDE u-line.com Safety and Warning Safety and Warning NOTICEPlease read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide: SAFETY ALERT DEFINIT...
Page 5 - Disposal and Recycling; Remove all consumable contents from the unit.
USER GUIDE u-line.com Disposal and Recycling Disposal and Recycling RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal, check a...
Page 6 - Environmental Requirements; CAUTION
USER GUIDE Environmental Requirements u-line.com Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher amb...
Page 7 - Electrical; WARNING; Always keep your working area dry.
USER GUIDE Electrical u-line.com Electrical WARNING ! SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter...
Page 8 - Cutout & Product Dimensions
USER GUIDE u-line.com Cutout & Product Dimensions Cutout & Product Dimensions PREPARE SITE Your U-Line product has been designed for either free-standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grill...
Page 10 - SAFETY •; INSTALLATION & INTEGRATION; • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE; Water Hookup; PREPARE PLUMBING; Turn off water supply and disconnect electrical supply; NOTICE
USER GUIDE u-line.com Water Hookup USER GUIDE Door Swing 1 u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Water Hookup PREPARE PLUMBING The water valve uses a standard 1/4" (6.35 mm) compression fitting. U-Line recommends using accessory water...
Page 11 - Turn on water supply and check for leaks
USER GUIDE u-line.com Water Hookup USER GUIDE Door Swing 2 u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 4. On the back panel, exit waterline in samelocation as drain line. 5. Turn on water supply and check for leaks 6. Reinstall back panel and g...
Page 12 - A gravity drain may be used if:; Connect to your local plumbing per the local code.; DRAIN CONNECTION; Drain
USER GUIDE u-line.com Drain If your U-Line unit did not come with a factory installed drain pump you must use a gravity style drain connection. For assistance in determining if your unit has a pump please contact U-Line. The floor drain must be large enough to accommodate drainage from all attached ...
Page 13 - See below for typical installations requiring a drain pump.; FACTORY INSTALLED DRAIN PUMP
USER GUIDE u-line.com Drain The maximum lift for the P60 drain pump is 10 feet. This must be done as close to the rear of the unit as possible. If your drain line will run up to a stand pipe, disposal or spigot assembly, or does not otherwise meet the requirements for a gravity drain, you may have o...
Page 14 - Drain Pump
USER GUIDE Drain Pump 1 u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Drain Pump NOTICE PLEASE READ this instruction completely before attempting to install or operate the unit. Improper hook-up can result in substantial property damage! If you a...
Page 16 - Route the vent tube up
USER GUIDE Drain Pump 3 u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE WARNING ! The back panel serves as a guard. Do not put your hands inside the ice machine cabinet or attempt to touch any components except the discharge tube during testing. CA...
Page 17 - General Installation; LEVELING INFORMATION; Turn to Adjust
USER GUIDE u-line.com General Installation General Installation LEVELING INFORMATION 1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not level, adjust the legs on the corners of the unit as necessary. 3. Confirm the unit is...
Page 18 - Grille Installation; REMOVING AND INSTALLING GRILLE; Align cabinet and grille holes and secure, but do not
USER GUIDE u-line.com Grille Installation Grille Installation REMOVING AND INSTALLING GRILLE Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. Do NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged. R...
Page 19 - Door Swing; allow for door handle.; Integrated
USER GUIDE Door Swing u-line.com Door Swing For Integrated models that are installed adjacent to a wall, 1/2" (13 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space for any knobs or pulls installed on the integrated panel/frame. Stainle...
Page 20 - Door Adjustments; DOOR ALIGNMENT AND ADJUSTMENT; Open door and remove gasket near the hinges.; REVERSING THE DOOR; Remove caps from screw heads on opposite side (2 on; Align and adjust the door:
USER GUIDE u-line.com Door Adjustments Door Adjustments DOOR ALIGNMENT AND ADJUSTMENT Align and adjust the door if it is not level or not sealing properly. If the door is not sealed, the unit may not cool properly, or excessive frost or condensation may form in the interior. NOTICEProperly aligned, ...
Page 21 - First Use
USER GUIDE First Use u-line.com First Use All U-Line controls are preset at the factory. Initial startup requires no adjustments. See CONTROL OPERATION section for more details. NOTICE U-Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible di...
Page 22 - SAFETY • INSTALLATION & INTEGRATION •; OPERATING INSTRUCTIONS; • MAINTENANCE • SERVICE; Control Operation; Up
USER GUIDE u-line.com Control Operation USER GUIDE Control Operation 1 u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Control Operation U-SELECT ® CONTROL Digital Display The 3000 Series units are controlled by a feature rich, advanced OLED displa...
Page 24 - To change display language select Languages from the; Sound Level; Press or to select the current sound level.
USER GUIDE u-line.com Control Operation USER GUIDE Control Operation 3 u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Languages The U-Line 3000 Series of models supports a number of display languages including English, Spanish, French, German and ...
Page 25 - Refer to CLEANING section regarding proper cleaning; Silent Mode; NOTE: Silent Mode will not silence any alerts.; To activate Silent Mode:; Press to make the ice thicker or to make the ice
USER GUIDE u-line.com Control Operation USER GUIDE Control Operation 4 u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Clean Cycle A clean cycle can be initiated through this menu. Once the cleaning cycle starts, the cycle cannot be stopped until c...
Page 27 - Ice; ICE CUBE THICKNESS ADJUSTMENT; Adjust ice thickness as follows:; and; ICE ADJUST
USER GUIDE u-line.com First Use USER GUIDE Ice 1 u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Ice ICE CUBE THICKNESS ADJUSTMENT NOTICE Ice thickness adjustment should only be made one increment at a time. Allow ice maker production to stabilize ...
Page 28 - Airflow and Product Loading
USER GUIDE u-line.com Airflow and Product Loading USER GUIDE Airflow and Product Loading 1 u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency. Do ...
Page 29 - Cleaning; Stainless Models
USER GUIDE Cleaning u-line.com Cleaning EXTERIOR CLEANINGVinyl Clad (Black or White) Models Clean surfaces with a mild detergent and warm water solution. Do not use solvent-based or abrasive cleaners. Use a soft sponge and rinse with clean water. Wipe with a soft, clean towel to prevent water spotti...
Page 30 - ULACLRCLEAN
USER GUIDE Cleaning u-line.com NOTICE Use only U-Line Ice Machine Cleaner ( ULACLRCLEAN ), available for purchase from u-line.com or your dealer. It is a violation of federal law to use this solution in a manner inconsistent with its labeling. Use of any other cleaner can ruin the finish of the evap...
Page 31 - When water begins flowing over the evaporator
USER GUIDE Cleaning u-line.com 9. When water begins flowing over the evaporator (approximately 3 minutes), pour 1 packet of CLRcleaner into the water trough. The cleaning process willlast approximately 45 minutes. 10.Dilute 1 tablespoon bleach in 1 gallon of warm water. Apply this solution to the en...
Page 32 - Cleaning Condenser; INTERVAL - EVERY SIX MONTHS; Clean the condenser coil using a soft brush with a
USER GUIDE u-line.com Cleaning Condenser Condenser Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be nece...
Page 33 - WINTERIZATION
USER GUIDE u-line.com Extended Non-Use Extended Non-Use VACATION/HOLIDAY, PROLONGED SHUTDOWN The following steps are recommended for periods of extended non-use: 1. Remove all consumable content from the unit. 2. Disconnect the power cord from its outlet/socket and leave it disconnected until the un...
Page 34 - SERVICE; Wire Diagram; OVERLOAD; RELAY; EMBRACO; FAN; CONTROL; PLUG
USER GUIDE Wire Diagram 1 u-line.com SAFETY • I NSTALLATI ON & INT E G RA T I O N • O P E RA T I N G I N ST R U C T I O N S • M A I N T EN A N C E • SERVICE Wire Diagram 42353_A WIRING DIAGRAM GREEN W/YELLOW (GROUND) WASTE WATER PUMP JUMPER PLUG WITHOUT P60 WASTE PUMP GREEN W/YELLOW (GROUND) BLA...
Page 35 - One Year Limited Warranty
Copyright © 20 20 U-Line Corporation. All Rights Reserved. | Publication Number 30379 | 1 1 /20 20 Rev. O U-Line Corporation (U-Line) Limited Warranty One Year Limited Warranty For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of ...