Page 2 - (a) Provide sufficient clearance in front of the
2 DESCRIPTION The Trion MP 600M air cleaner is designed to capturemachine tool fluids, metal dust and smoke for clean airfiltration. It can be mounted to a wall, frame, platform, ordirectly on the machine tool. Mist, dust, and smoke aredrawn from each machine through an external duct intothe air cle...
Page 3 - Figure 1 - MP 600M High Static; SPECIFICATIONS
3 Figure 1 - MP 600M High Static SPECIFICATIONS STANDARD OPTIONAL MP600M and High Static MP 600M Voltage 115 208-230 208-230/460 575 115/230 Phase 1 1 3 3 1 HZ 60 60 60 60 60 AMPS 17 9.4-8.5 4.9-4.6/2.3 1.9 8.0-4.0 Motor ½ hp 1 ½ hp 1 ½ hp 1 ½ hp ½ hp CFM 600 600 600 600 600 Shipping Weight 175 lbs ...
Page 4 - Figure 2 – Dimension and Access Data; GENERAL SAFETY INFORMATION; WARNING: RISK OF ELECTRIC SHOCK; Read this manual thoroughly before beginning; INSTALLATION; WALL OR VERTICAL SUPPORT MOUNTED
4 Figure 2 – Dimension and Access Data GENERAL SAFETY INFORMATION WARNING: RISK OF ELECTRIC SHOCK These serving instructions are for use by qualifiedpersonnel only, To reduce the risk of electric shock, donot perform any servicing other than that contained inthe operating instructions unless you are...
Page 6 - Figure 4 - MP 600M Inlet Plenum and Stand Options
6 Figure 4 - MP 600M Inlet Plenum and Stand Options
Page 7 - Figure 5 – Wiring Diagrams for Model MP 600M
Page 8 - Figure 6 – Wiring Diagram
Page 9 - Figure 6A – Motor Wiring Diagram
Page 10 - OPERATION; Estimated Filter Change Pressure; HEPA; MAINTENANCE; Clean impinger by first rinsing with warm to hot
10 The MP600M is wired directly from the power sourcewith 20 amps minimum, service utilizing 3 wire groundedcable, (115-208-230-460-575/60/3) for single 208-230/60/1, phase service and 4 wire grounded cable for 3phase service, routed through appropriate conduit (Seefigure 5 wiring diagram). All wiri...
Page 12 - Figure 7 – MP 600M Unit Assembly
Page 14 - Figure 8 – Filter Locking Mechanism; Access opening increased 3.5” height
14 Figure 8 – Filter Locking Mechanism - Access opening increased 3.5” height - 16 GA tapered filter retainer welded in door and cabinet rear - As door closes, filter gasket is compressed and seal is made
Page 15 - Impinger
15 Figure 9 – System Performance Curves (without Filters) Flow – CFM @ 60 Hz Added Static @ Filter 600 CFM 1000 m 3 /hr Filter Inches W.C. Pascals 99.97% DOP HEPA 1.00 250 95% DOP 0.35 87 90-95% ASHRAE 0.20 50 80-85% ASHRAE 0.15 37 60-65% ASHRAE 0.10 25 45-55% ASHRAE 0.05 13 Impinger 0.15 37 Aluminu...
Page 16 - WARRANTY
WARRANTY All Trion air cleaners are warranted for component failure and workmanship for aperiod of three years after purchase. Do not return defective parts without priorpermission from the factory. Contact your local Trion Distributor or Trion CustomerService Department at 1-800-884-002 of Fax 1-80...