Toshiba MA-186 - Manuals
Toshiba MA-186 – Manual in PDF format online.
Manuals:
Manual Toshiba MA-186
Summary
(i) Safety Summary EO1-11115 Safety Summary Personal safety in handling or maintaining the equipment is extremely important. Warnings and Cautionsnecessary for safe handling are included in this manual. All warnings and cautions contained in thismanual should be read and understood before handling o...
(ii) Safety Summary EO1-11115 CAUTION This indicates that there is the risk of personal Injury or damage toobjects if the machines are improperly handled contrary to this indication. If foreign objects (metal fragments,water, liquids) enter the machines,first turn off the power switches anddisconnec...
EO1-11115 MA-186-100 SERIES TABLE OF CONTENTS Page 1. Introduction .................................................................................................................................... 1 2. Unpacking ........................................................................................
- 3 - EO1-11115 MA-186-100 SERIES 1 3. Outline of Preparation Procedure Before Operating the ECR This chapter shows the outline of set-up procedure of the ECR before actually starting the ECR operation. Remove the cash register from the carton, referringto Chapter 2. Unpacking on page 2. And take ou...
- 4 - EO1-11115 MA-186-100 SERIES Perform programming of the register, such as De-partments and PLUs, according to the require-ment of the market and your store (refer to Chap- ter 14 and thereafter). 7 8 If any optional keys are installed or relocated onthe keyboard, the optional key setting progra...
- 5 - EO1-11115 MA-186-100 SERIES 4. Appearance and Nomenclature Operator’s Display Used by the operator to confirm the entrycontents and the status of the register. (page7) Customer’s Display Provided for the customer to see the amountentered for each item and sale total. (page 7) Journal Window/Re...
- 6 - EO1-11115 MA-186-100 SERIES 5. Control Lock and Control Keys Control Keys There are three types of Control keys: the REG (registration) key, the MA (manager) key, and the S(service) key. REG Key: The REG key is used by the cashier or clerk who operates ordinary transac-tion entries. This key c...
- 7 - EO1-11115 MA-186-100 SERIES AMOUNT PLU DP RPT TL ST CG SIGN ON ALM R OFF AMOUNT TL ST CG Customer’s Display SIGN ON ALM R OFF TL ST CG 6. Display The Operator’s Display (front display) is located at the top of the register just above the keyboard. TheCustomer’s Display may be used only as a re...
- 8 - EO1-11115 MA-186-100 SERIES Numeric Display AMOUNT (8 digits for total display, 7 digits for entries): Displays the numeric data, such as amount, quantity, etc. Whenthe obtained total or subtotal amount is 8-digit, the RPT digit isalso used for the amount display. When no entries are under way...
- 9 - EO1-11115 MA-186-100 SERIES 7. Keyboard The following is the standard keyboard layout, which was initially set at the factory. This register is designedto be capable of programming most of the keys at desired locations or adding some optional keys in placeof the current keys. If you are in nee...
- 10 - EO1-11115 MA-186-100 SERIES 8. Installing the Paper Roll The printer may be used for journal-format print (standard status) or receipt-format print (optional status).For reversing the status, refer to Chapter “16. System Option Setting”, Address 2-Bit 7” on page 72. 1 2 3 Turn the Control Loc...
- 13 - EO1-11115 MA-186-100 SERIES Examples) 1:05 a.m.: 1:32 p.m.: 9. Time and Date Setting Time Setting or Adjustment The register has a clock function. Once the time is set, the time is kept even when the power is turned off.The 24-hour system (the military time) is used for time setting, display,...
- 14 - EO1-11115 MA-186-100 SERIES Month-Day-Year order Month Day Year NOTE: The date set/print order is Month-Day-Year. If you want to change the order intoDay-Month-Year or Year-Month-Day, see Chapter “16. System Option Setting”,Address 16 - Bits 7 and 8 on page 81. Examples) To set 28 May, 1997: ...
- 15 - EO1-11115 MA-186-100 SERIES Displaying the Time The current time is displayed in the “AMOUNT” area when the Control Lock is turned to REG from any otherposition. When the Control Lock position is changed or any entry operation starts, the displayed timedisappears. Time Display Format:(Example...
- 19 - EO1-11115 MA-186-100 SERIES Examples) 7% 12% 8.55% To reset the rate once set: GST Rate Setting (applicable to Canada only) Please note the following before operating the GST rate setting. The following preparations are required: 1) Select the “GST Active” status in Chapter “16. System Option...
- 21 - EO1-11115 MA-186-100 SERIES → |Amount| → Tax Calculation Test Tax calculation can be tested by the following procedure. This operation will not affect any sales data. Operating Procedure: Use the MA Key to turn the Control Lock to “X”. Enter any amountthrough NumericKeys. The enteredamount ...
- 22 - EO1-11115 MA-186-100 SERIES *1 *5 *2 *2 Key Code Key Name 85 NS (No-sale) 87 LC OPEN (Listing Capacity Open) 90 #/CID (Non-add Number/Cash-in- drawer) 91 #/NS (Non-add Number/No-sale) 92 PLU (Price-Look-Up) 93 @/FOR (At/For; Multiplication) 94 RECEIPT ISSUE (Post-receipt) 95 C (Clear) 97 TX/M...
- 23 - EO1-11115 MA-186-100 SERIES Fill in:Key Name → Key Code → (Refer to the “Listof Keys” on the pre-ceding page.) For the StandardKeyboard Layout,refer to Chapter “7.Keyboard” on page9. (The BLIND position is theunmarked step next to “Z”.) Only to read the Key Code currently set on the key...
- 25 - EO1-11115 MA-186-100 SERIES 12. Daily Operation Flow The following shows a typical daily operation flow on the register. Reference Chapter Before Opening the Store ... • Ensure that the register is firmly plugged in the wall outlet. • Check if enough portion of paper roll is left. • Check the...
- 26 - EO1-11115 MA-186-100 SERIES 13. Training This chapter describes a training provided for new employed cashiers. After entering the training mode,a cashier may operate the same transaction entries as those in the REG mode. The data in the trainingmode is processed to the Electronic Journal buff...
- 27 - EO1-11115 MA-186-100 SERIES Training Start Receipt Training End Receipt Receipt issued in Training Mode Thank you Call again 05.- 28.- 9 7 ★ ★ ★ ★ 9 0 41.31 8 - 5 0 TT Thank you Call again 05.- 28.- 9 7 ★ ★ ★ ★ 0 0 41.41 8 - 5 3 TT Thank you Call again 05.- 28.- 9 7 ★ ★ ★ 10.0 0 ★ 2.5 0 ★ 12....
- 31 - EO1-11115 MA-186-100 SERIES PO AT/TL . . . Paid Out <operable outside a sale only> A paid-out transaction is used when an amount of money is removed from the drawer without relating toa sale, for the purpose of paying to wholesalers, etc. This operation must be performed outside a sale ...
- 32 - EO1-11115 MA-186-100 SERIES Department Status Programming: To use Department Keys, program how each Department Key is to be used, in accordance withmerchandise categories, operativity of the key, etc. Condition: After Daily Financial Reset and Periodical Financial Reset (and All PLU Reset if ...
- 34 - EO1-11115 MA-186-100 SERIES Thank you Call again 05.- 28.- 9 7 0.3 ★ 0 8 1 3 0 5 1 2 0 4 0 0 - 1 0 1 0 - 0 5 0 1 0 00.51 3 - 1 2 Dept. 10 RTN MDSE Department Status Program Receipt Format: Key Operation Control Lock: SET Key Type Status 0: Itemized1: Single-item4: Other Income (Itemized) 5: O...
- 35 - EO1-11115 MA-186-100 SERIES ex.) .......... indicates $ 39.99 .......... Allows to enter equal to or smaller than $39.99 in sale entries. Department LC (Listing Capacity) Programming: The LC setting is used to check an amount limit error. By setting the LC, an amount entry (due perhapsto a mi...
- 36 - EO1-11115 MA-186-100 SERIES AT/TL NOTES: 1. All the Department Keys are open departments (no preset price set) as initial status. 2. If a Department Key is pressed with no Preset Price entry, the Key is set as an open-price Department Key. 3. If “0” is entered as Preset Price, the Department ...
- 37 - EO1-11115 MA-186-100 SERIES Dept. Price of the item(max. 7 digits; orlimited by theDepartment LC) . . . ( ) Dept. DPT SHIFT . . . To enter a sale item of theDepartment Nos. 21 to 40. If an error occurs here:Possible cause of error:• The price entered exceeds the LC. → See the Listing Capacity...
- 40 - EO1-11115 MA-186-100 SERIES PLU (PLU Key) CA Thank you Call again 05.- 28.- 9 7 0 7 ★ 10.0 0 ★ 10.0 0 0 10.50 9 - 1 2 ← Automatically finalized as cash sale (Cash Total) Single-item Department Entry If a Department key is programmed with single-item status, an entry through the key immediate...
- 41 - EO1-11115 MA-186-100 SERIES Programming PLUs PLU Table Setting: Condition: To change setting of a PLU: When the required PLU sales total memory is zero (i.e.,when no sales are made or after a PLU Reset Report is taken to reset the sales data of the PLU intozero)To add new PLUs: Any time outsi...
- 42 - EO1-11115 MA-186-100 SERIES Thank you Call again 05.- 28.- 9 7 0.4 ★ 00.5 0 4 ★ 1.0 0 @ 01.0 0 2 ★ 2.0 0 @ 01.1 0 1 ★ 1 23.0 0 @ 20.0 0 3 ★ 10.0 0 @ 05.0 0 5 ★ 0.5 0 @ 10.0 0 9 ★ 3.0 0 @ 15.0 0 9 @ 00.7 0 00.61 3 - 1 4 PLU Code LinkDepartmentNo. Preset Price Blank for Pre-set Price indi-cates...
- 43 - EO1-11115 MA-186-100 SERIES → PLU Code of PLUto be deleted PLU Code deleted Deletion Symbol LineTotal number of PLUsremaining set in memory Thank you Call again 05.- 28.- 9 7 0.4 ★ 01.0 - - - - - - - - - 00.6 0 00.71 3 - 1 6 VD ITEM CORR 4 @/FOR 0 1 AT/TL PLU ( ) or Repeat for other PLUs,...
- 44 - EO1-11115 MA-186-100 SERIES PLU Price Change Setting Receipt Format: Key Operation Control Lock: SET PLU Code New Preset Price 1 1 AT/TL PLU PLU Code Link Department No.New Preset Price Thank you Call again 05.- 28.- 9 7 0.0 ★ 01.1 0 1 ★ 1 23.4 5 @ 0 02.10 8 - 5 9 PL 5 #/CID 3 2 1 4 Z OFF X R...
- 45 - EO1-11115 MA-186-100 SERIES PLU To repeat PLU PLU Code PL PL TM TM 20.0 ★ 10.0 0 20.0 ★ 10.0 0 . . . Price PLU PLU Code To repeat AMT AMT PL TM . . . @/FOR Quantity PLU Code PLU . . . PLU Code PLU Quantity 4. X ★ 10.0 0 @ 20.0 ★ 40.0 0 . . . @/FOR Unit Price AMT ← ←← ← Quantity Unit Price...
- 46 - EO1-11115 MA-186-100 SERIES PL CA Thank you Call again 05.- 28.- 9 7 10.1 ★ 3.4 0 ★ 3.4 0 0 10.70 9 - 1 8 (Listing Capacity Open Key) LC OPEN LC OPEN % + % – Single-item PLU Entry If a Department key is programmed with Single-item Status, an entry through a PLU which links tothe Department im...
- 47 - EO1-11115 MA-186-100 SERIES Z OFF X REG SET for %- rate for %+ rate This portion is required only when anydecimal portion is contained in the rate. % rate 0 to 99.999 % + • % – • 0 7 2 5 1 5 4 5 • 3 • 8 %- 5% is set. %+ 10% is set. Thank you Call again 05.- 28.- 9 7 0.0 ★ 5. % - 0 01.40 8 - 5...
- 48 - EO1-11115 MA-186-100 SERIES . . . %- Manual Rate %- %+ %+ 0 1 ★ 6.0 0 5. % - -0.3 0 Manual Rate ← Dept 1 $6.00 5% on $6.00 = $0.30is discounted. %- %+ %+ ★ 15.0 0 10. % + ★ 1.5 0 ST ← Subtotal $15.00obtained 10% on $15.00 = $1.50 is added. . . . TM Z OFF X REG SET %- ST % Key Operat...
- 49 - EO1-11115 MA-186-100 SERIES DOLL DISC . . . Amount to be discounted (max. 7 digits) An amount of $0.40 is entered asDollar Discount -0.4 0 ← (Dollar Discount Key) Z OFF X REG SET ST ITEM CORR (Item Correct Key) Dept 1 $6.00 is entered but item-corrected. ITEM CORR 0 1 ★ 6.0 0 0 1 ★ 6.0 0 VD T...
- 51 - EO1-11115 MA-186-100 SERIES ALL VOID (All Void Key) Thank you Call again 05.- 28.- 9 7 0 2 ★ 4.5 0 14. X 0.3 0 @ 0 3 ★ 4.2 0 20.0 ★ 10.0 0 ★ 18.7 0 ★ ★ ★ ★ ★ ★ 0 12.71 3 - 4 2 ITEM CORR C ← Prints the subtotalwhen TransactionCancel is executed. PL VD ST TM TM TM ← All Void (TransactionCanc...
- 53 - EO1-11115 MA-186-100 SERIES Symbol for Subtotal ★ 22.9 1 ST Subtotal Amount ← ← ST (Subtotal Key) Z OFF X REG SET ST .......... Z OFF X REG SET TXBL TL (Taxable Total Key) TXBL TL Subtotal Read When the sale total of the current sale is to be read by the customer’s request or the operator’s ...
- 56 - EO1-11115 MA-186-100 SERIES Each of these keys is used to reverse the tax status of a required Department or PLU item to be enteredin a sale. It is also used to reverse the Non-taxable status of [% +], [% -], and [DOLL DISC] keys intoTaxable status. The Modifier Keys are effective only for on...
- 57 - EO1-11115 MA-186-100 SERIES EX EX The sale portion (pre-taxed amount) subject to the tax exemption (Tax/PST 1 in this example). Sale portion (pre-taxed)exempted from GSTSale portion (pre-taxed)exempted from Tax/PST 1Sale portion (pre-taxed)exempted from Tax/PST 2 ★ 1.0 0 1 EX ← EX EX EX EX At...
- 58 - EO1-11115 MA-186-100 SERIES Print/Non-print Options on Sale Receipts The following are items that can be programmed to be printed or not on sale receipts.To change the print/non-print status, refer to Chapter “16. System Option Setting” on page 69. Forchanging the print/non-print status of ea...
- 59 - EO1-11115 MA-186-100 SERIES (or ) Declaration of Program No.7 for Hourly Range Tableprogramming Hour (0 to 23) Repeat for setting next Hourly Ranges (max. 24 hourly ranges) Z OFF X REG SET 7 AT/TL Enter the time that ends the HourlyRange, in the 24-hour system using themilitary time. (The tim...
- 60 - EO1-11115 MA-186-100 SERIES 7 0 #/CID AT/TL @/FOR 7 0 0 0 1 AT/TL Thank you Call again 05.- 28.- 9 7 0.7 ★ 0 8 - 0 00 9 - 0 01 0 - 0 01 3 - 0 01 6 - 3 01 8 - 0 00 01.00 8 - 5 1 @/FOR 0 0 8 0 0 9 0 0 3 1 0 3 6 1 0 0 8 1 #/CID #/CID #/CID #/CID #/CID #/CID Item Initial Status System Option Befo...
- 61 - EO1-11115 MA-186-100 SERIES Taking Read and Reset Reports Fundamental Concepts of Various Types of Reports Four types of Reports are available in connection with the Control Lock positions and the periods of dataaccumulation: Daily Read Report: It can be issued at any time and any number of t...
- 62 - EO1-11115 MA-186-100 SERIES DPT SHIFT Report Name Key Operation Sample Page * Financial Read Control Lock: X 63 * Financial Reset (NOTE 2) Control Lock: Z Hourly Sales Read Control Lock: X 66 Hourly Sales Reset Control Lock: Z All PLU Sales Read Control Lock: X 66 All PLU Sales Reset Control ...
- 63 - EO1-11115 MA-186-100 SERIES Thank you Call again 05.- 28.- 9 7 Z ★ 13.4 05.7 1 5 06. ★ 13.4 05.7 1 0 1 1 0 21. ★ 42.7 5 0 2 4 63. ★ 31.0 6 0 3 8 3 84. ★ 12.0 75.5 0 0 4 2 2. -2.0 0 0 5 1 3. ★ 1.5 0 0 6 0 0. ★ 0.0 0 0 7 1 1. ★ 10.0 0 0 8 0 0. ★ 0.0 0 0 9 1 4. - 12.0 0 1 0 0 0. ★ 0.0 0 4 0 0 @ ...
- 65 - EO1-11115 MA-186-100 SERIES - Memory Balance - Grand Total = Sum of Daily Gross Sales Gross Sale = (Sum of Depts) + (Sum of Tax/PST 1 & 2) + (Percent Charge) NOTE below + (Percent Discount on Item) + (Sum of Negative Depts) + (Item Correct)+ (Void) + (Returned Merchandise) + (Negative Tax...
- 66 - EO1-11115 MA-186-100 SERIES Daily Hourly Sales Read or Reset Report Thank you Call again 05.- 28.- 9 7 1 0 Z ★ ★ 0 8 - 0 00 9 - 0 0 9 ★ 69.1 8 1 0 - 0 0 7 ★ 48.6 6 1 3 - 0 01 6 - 3 01 8 - 0 0 00.0 1 Z 0 04.81 3 - 4 3 CU CU Report Type Symbol Sales Data in Hourly Range from 18:00 yesterday to ...
- 67 - EO1-11115 MA-186-100 SERIES Daily Media Sales & In-drawer Read Report Thank you Call again 05.- 28.- 9 7 X 1 6 ★ 1 17.8 4 ★ 1 05.9 3 2 ★ 10.5 0 2 ★ 7.4 1 0 04.71 3 - 4 2 CU CH CK ID ID ID TL Report Type Symbol (Daily Read Report only) Total Customer Count All Media Sales Amount Cash-in-dr...
- 68 - EO1-11115 MA-186-100 SERIES Daily Individual Department Read Report Periodical Cashier Read or Reset Report Report Type Symbol Thank you Call again 05.- 28.- 9 7 4 Z ★ ★ 1 1 1 33.4 5 ★ 72.6 5 0. @ ★ 0.0 0 @ ★ ★ 2 ★ ★ 8 00.0 1 Z 0 05.01 3 - 4 3 CL CL GS GS CU CL 4X: Periodical All Cashier Read...
- 69 - EO1-11115 MA-186-100 SERIES Repeat for Bit status changes in all the required Addresses. Bit Nos. that are set to “SET” status(max. 8 Bit Nos. combination of 1 to 8) Address No. (max. 2digits; 1 to 16) ( ) or Z OFF X REG SET 8 1 @/FOR → ST #/CID AT/TL #/NS 16. System Option Setting This op...
- 70 - EO1-11115 MA-186-100 SERIES NOTES: 1. Do not program any Bit No. shaded and filled with “vacant” in the Address tables on the following pages. If programmed, performance of the register will not be guaranteed. 2. The Initial Status of each Bit is indicated by a dotted frame such as: If you ha...
- 71 - EO1-11115 MA-186-100 SERIES Content Bit No. Selective Status RESET SET Time on Journal and every Receipt in REG, X, Z, SETmodes Purchased Item Count on Sale Receipts Manual Subtotal on Sales Receipts GT (Grand Total) on Financial Reports (in X and Z modes) -- vacant -- Sum of Negative Departm...
- 84 - EO1-11115 MA-186-100 SERIES Reading of the Remaining Lines of E.J. Memory This operation is used to display the remaining number of lines in the E.J. buffer. The remaining numberof lines is displayed in the Amount portion of the display. Operation ST 1 1 1 1 Fixed code for ElectronicJournal o...
- 86 - EO1-11115 MA-186-100 SERIES Format Contents to be Printed for Verification Page Department Preset Price Read: 87 Preset Price of each Department Department LC and Status Read: 87 LC(Listing Capacity) and Status of each Department PLU Table Read: 88 Preset Price and Link Department of each PLU...
- 87 - EO1-11115 MA-186-100 SERIES Thank you Call again 05.- 28.- 9 7 X 0 1 01. 7 3 0 2 02. 9 4 0 3 00. 5 7 0 4 00. 0 0 - 0 5 00. 0 0 0 6 00. 0 0 0 7 10. 0 0 0 8 10. 0 0 0 9 00. 0 0 1 0 10. 0 0 - 0 01.80 9 - 0 3 Thank you Call again 05.- 28.- 9 7 X 0 1 @ 0 2 @ 0 3 @ 0 4 ★ 1.0 0 @ 0 5 ★ 2.0 0 @ 0 6 @...
- 88 - EO1-11115 MA-186-100 SERIES PLU Table Read Thank you Call again 05.- 28.- 9 7 X 00.5 0 4 ★ 1.0 0 @ 01.1 0 1 ★ 1 23.4 5 @ 05.0 0 5 ★ 0.5 0 @ 06.0 1 0 ★ 3.0 0 @ 07.0 0 3 @ 07.1 0 8 ★ 8.0 0 @ 07.2 0 9 ★ 9.0 0 @ 19.9 0 3 ★ 10.0 0 @ 0 01.90 9 - 0 4 ← PLU Code Link Department No. Preset Price (Bl...
- 89 - EO1-11115 MA-186-100 SERIES Thank you Call again 05.- 28.- 9 7 X 0 1 2 6 0 2 7 8 0 3 0 0 4 0 0 5 0 0 6 0 0 7 1 3 0 8 1 0 9 0 1 0 0 1 1 6 8 1 2 0 1 3 2 1 4 4 5 1 5 4 1 6 2 8 0 02.20 9 - 0 8 Address No. SET Bit Nos. ← ↓ System Option Read NOTE: The above sample shows the initial SET Bit Nos. ...
- 90 - EO1-11115 MA-186-100 SERIES 1 2 3 Turn the Control Lock to the REG positionusing the Control Key. To remove the Printer Cover, insert thePrinter Cover Key to the Printer CoverLock, and then turn it 90 ° clockwise. Z OFF X REG SET 20. Paper Roll Replacement and Other Maintenance Replacing the ...
- 91 - EO1-11115 MA-186-100 SERIES 4 Depress the [FEED] key to feed the re-maining paper end. CAUTION: Never try to pull out the re-maining paper end by hand.It may cause a paper jam. Replacing the Paper Roll (When used for journal) After a reset report is taken or when a red line appears on the edg...
- 93 - EO1-11115 MA-186-100 SERIES Replacing the Ink Ribbon This ink ribbon is a consumable part and a TOSHIBA TEC’s exclusive. Ask yourTOSHIBA TEC representative about the order of the ink ribbon. 1 Turn the Control Lock to the OFF position usingthe Control Key. 2 3 To remove the Printer Cover, ins...
- 95 - EO1-11115 MA-186-100 SERIES 1 Replenishing Ink to the Store Name Stamp Turn the Control Lock to the OFF positionusing the Control Key. 2 3 To remove the Printer Cover, insert thePrinter Cover Key to the Printer CoverLock, and then turn it 90 ° clockwise. Remove the Stamp from the Stamp PrintU...
- 96 - EO1-11115 MA-186-100 SERIES 5 Return the stamp in the reverse procedure. 6 After replenishing ink, depress the [NS]key to check the density of the printedmessage. * Ordering a Store Name Stamp which contains your store name, address, andtelephone No., etc. is available. Refer topage 109 for d...
- 98 - EO1-11115 MA-186-100 SERIES Remove the paper roll, the Take-up Reel (ifused for Journal), and the Battery Cover. 3 Replace the old batteries with new ones.(Batteries: SUM-3 1.5V x 3 pieces) NOTE: Do not mix used and new batteries in the battery compartment. Return the items removed in Step 3,...
- 100 - EO1-11115 MA-186-100 SERIES 21. In Case of the Power Failure If a power failure occurs during business hours, all sales data stored in the memory are automaticallyprotected by the batteries installed in the register. When any data was being printed on the power failure,the same data is autom...
- 102 - EO1-11115 MA-186-100 SERIES 3. Trouble concerning KeyboardKey on the keyboard does not function. Cause 1: Control Lock is in the OFF position. Measure: Turn the Control Lock to the positions other than OFF using the Control Key. Cause 2: Failure of the keyboard itself Measure: Ask the store ...
- 103 - EO1-11115 MA-186-100 SERIES Error tone beeps Cause 1: Operation procedure is incorrect. Measure: Depress the [C] key to clear the error, then check the operation procedure you attempted. Cause 2: Control Lock position is incorrect. Measure: Turn the Control Lock to the correct position using...
- 104 - EO1-11115 MA-186-100 SERIES Use the S Key to turn the ControlLock to “BLIND”. 23. Status Clear and Memory Clear Operations The operations described in this chapter are provided for initial start-up of the machine or emergency butnot to be operated as part of daily routines. Do not perform an...
- 105 - EO1-11115 MA-186-100 SERIES Depress the following Numeric Key according to the display and print format for zero amount: Sales Memory Clear The operation defined as “Sales Memory Clear” will only clear the sales data accumlated in the register’smemory (report memory). The programmed data wil...
- 106 - EO1-11115 MA-186-100 SERIES Z OFF X REG SET (BLIND) Numeric Key 3 Zero-amount Format 0 . 0 0 . 0 for use in US or Canada AT/TL 9 1 9 All Memory Clear If the register becomes completely inoperative due to battery discharge or malfunction of the programmemory, the All Memory Clear operation mu...
- 108 - EO1-11115 MA-186-100 SERIES Memory Protection Dry Battery SUM-3 1.5 x 3 pieces; Life of about 1 year.(Be certain to replace batteries with new ones every year.) Handling the Batteries • When inserting batteries, place them so that the positive (+) and negative (-) ends face the proper direct...
- 109 - EO1-11115 MA-186-100 SERIES STAMP ORDER Dear Customer; A Receipt Stamp (Electro-stamp) “Thank you Call again” comes with each unit. If you prefer printing your companyname or message to Thank you Call again for receipt inprint, please place your order by using the order formbelow. Please com...
Toshiba Manuals
-
Toshiba 26C100U
User Manual
-
Toshiba 26C100U
Manual
-
Toshiba 55SL412U
User Manual
-
Toshiba 55SL412U
Manual
-
Toshiba 50L5200U
User Manual
-
Toshiba 50L5200U
Manual
-
Toshiba 24V4210U
User Manual
-
Toshiba 24V4210U
Manual
-
Toshiba 40L3400U
User Manual
-
Toshiba 40L3400U
Manual
-
Toshiba 50L1350U
User Manual
-
Toshiba 50L1350U
Manual
-
Toshiba 24SLV411U
User Manual
-
Toshiba 24SLV411U
Manual
-
Toshiba 50L2400U
User Manual
-
Toshiba 58L7350U
User Manual
-
Toshiba 32L2400U
User Manual
-
Toshiba 32L2400U
Manual
-
Toshiba 50L1400U
User Manual
-
Toshiba 50L1400U
Manual