Page 2 - NOTICE; Safety Precautions; NOTES
- 1 - 6F8A0883 NOTICE We thank you very much for your purchase of our GF630 series electromagnetic flowmeter detector. Integral type GF630/LF600F and GF630/LF610F Separate type detector GF632 This instruction manual describes the notes on using an electromagnetic flowmeter detector, installation, co...
Page 3 - SAFETY PRECAUTIONS; Explanation of signal words; WARNING; Safety symbols
- 2 - 6F8A0883 SAFETY PRECAUTIONS Safety signs and labels affixed to the product and/or described in this manual give important information for using the product safely. They help prevent damage to property and obviate hazards for persons using the product. Make yourself familiar with signal words a...
Page 4 - Safety Precautions for Installation and Wiring; DON; DON
- 3 - 6F8A0883 SAFETY PRECAUTIONS Safety Precautions for Installation and Wiring WARNING Do not disconnect while circuit is live unless location is known to be nonhazardous. DON ’ T Live part of electric circuit or a high temperature department can cause explosion . Do not modify or disassemble ...
Page 5 - CAUTION
- 4 - 6F8A0883 SAFETY PRECAUTIONS (continued) Safety Precautions for Installation and Wiring CAUTION Install a switch and fuse to isolate the GF630/LF600F, GF630/LF610F and GF632 from mains power. Use an appropriate device to carry and install the GF630/LF600F, GF630/LF610F and GF632. DO Power s...
Page 6 - Safety Precautions for Maintenance and Inspection; DON’T; Usage limitation
- 5 - 6F8A0883 SAFETY PRECAUTIONS (continued) Safety Precautions for Maintenance and Inspection CAUTION Do not conduct wiring work with wet hands . Do not conduct wiring work when power is applied . DON’T Wet hands may result in electric shock . DON’T Wiring while power is applied can cause elec...
Page 7 - Handling Precautions
- 6 - 6F8A0883 Handling Precautions To obtain the optimum performance from the GF630/LF600F, GF630/LF610F and GF632 for years of continuous operation, observe the following precautions. (1) Do not store or install the flowmeter in: ・ Where there is direct sunlight . ・ Where there is snow and ice Inf...
Page 8 - About disposal
- 7 - 6F8A0883 Handling Precautions (continued) (6) If the inside of the converter and detector's terminal box are wetted or humidified, it may cause insulation deterioration, which can result in fault or noise occurrence . So do not conduct wiring in the open air on rainy days . Also, be careful no...
Page 9 - Table of Contents
- 8 - 6F8A0883 Table of Contents SAFETY PRECAUTIONS ····················································································· 2 Handling Precautions ······························································································ 6 1. Product Inspection and Storage ········...
Page 10 - Product Inspection and Storage; Product Inspection
- 9 - 6F8A0883 1. Product Inspection and Storage 1.1 Product Inspection GF630 series electromagnetic flowmeter is shipped in a cardboard container filled with shock-absorbing materials. Open the package carefully and check as follows: Make sure the following items are included in the package. For ...
Page 11 - Features
- 10 - 6F8A0883 2. Overview The GF630/LF600F, GF630/LF610F and GF632 electromagnetic flowmeter can be use in the following hazardous (classified) locations. Class Ⅰ , Division 2, Groups A, B, C and D, Class Ⅱ , Division 2, Groups E, F and G Class Ⅲ The GF630 and GF632 electromagnetic flowmeter measu...
Page 13 - Figure 3.1.2 Appearance of Detector GF632
- 12 - 6F8A0883 3.1.2 Appearance of Detector GF632 Note: The ground cables are included in the package, so install them to flanges as shown in the Fig.4.5 as needed. (The screws are equipped to detector flanges.) Separate Figure 3.1.2 Appearance of Detector GF632 for Excitation cable 1/2 – 14 NPT Fl...
Page 14 - Construction of the terminal blocks; Terminal Block Construction of GF632 Type
- 13 - 6F8A0883 3.2 Construction of the terminal blocks 3.2.1 Terminal Block Construction of GF630/LF600F and GF630/LF610F Type For the detail of the converter, check the converter LF600F and LF610F instruction manual. 3.2.2 Terminal Block Construction of GF632 Type Separate Integral To signal cable...
Page 15 - Safety Precautions for Installation
- 14 - 6F8A0883 4. Installation Safety Precautions for Installation WARNING Do not active live circuits under environment of explosive atmospheres. DON’T Live part of electric circuit or a high temperature department can cause explosion . Do not use parts of other products . DON’T Protective per...
Page 19 - Figure 4.5 GF63* flowmeter detector piping connections; grounding rings
- 18 - 6F8A0883 4.2.2 Installation Procedure In addition, in the case of detector with FEP lining, make sure to install the gaskets between grounding ring and lining. The gaskets must be installed so as not to protrude into the measurement tube. And install the ground cables to each flange of detect...
Page 20 - and tightening torque)
- 19 - 6F8A0883 To mount the GF63*, place it between the upstream and downstream pipe flanges and tighten it with flange bolts and nuts. See Figure 4.5 and follow the procedure below: 1. Insert two lower mounting bolts through the clearance holes in the upstream (or downstream) pipe flange. 2. Insta...
Page 21 - Table 4.1 Bolt length and Nut tightening torque
- 20 - 6F8A0883 Table 4.1 Bolt length and Nut tightening torque *1: 1[N ・ m] is 0.7376 [ft ・ lbf]. ANSI class 150 Machine Bolts Meter size P.C.S Diameter Length [inch] Tightening torque [N ・ m] *1 15mm 1/2” 4 1/2” 2” 7 to 9 25mm 1” 4 1/2” 2.16” 14 to 17 32mm 1 1/4” 4 1/2” 2.16” 19 to 24 40mm 1 1/2” ...
Page 22 - Figure 4.6 Transportation of GF63* flowmeter detector
- 21 - 6F8A0883 4.2.3 Precautions in transportation To prevent the device from being damaged during transportation, the original packing should be left untouched until the device arrives near the intended installation site. The detector is equipped with hanging hooks. Lift it as shown in Figure 4.5....
Page 23 - Piping Connections; (1) Required Upstream Straight Pipe Length; Table 4.3 Required straight pipe length on the upstream side; bent
- 22 - 6F8A0883 4.3 Piping Connections (1) Required Upstream Straight Pipe Length If various joints are used upstream of the detector outlet, the straight pipe length as shown in Table 4.3 is required. Table 4.3 Required straight pipe length on the upstream side L: Required straight pipe length—stra...
Page 28 - Wiring; Safety Precautions for Wiring; explosion; DO; explosion
- 27 - 6F8A0883 5. Wiring Safety Precautions for Wiring WARNING DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS LOCATION IS KNOWN TO BE NONHAZARDOUS. DON’T Live part of electric circuit or a high temperature department can cause explosion . Do not active live circuits While assembly of all compon...
Page 30 - Notes on wiring
- 29 - 6F8A0883 Notes on wiring CAUTION (1) The apparatus does not be provided with the cable connections. Please prepare yourself for the cable connections which could be used in Division2 hazardous locations. The cable lead –in section must be tightened securely to keep air tightness. (2) Select t...
Page 31 - External Device Connections and Grounding; ground the shield of output cable basically at the receiving side.; Ground with the FG terminal.
- 30 - 6F8A0883 5.2 External Device Connections and Grounding For the notes on connecting, wiring and installation of the combined converter, check the model number of the combined converter and read the instruction manual of the relevant converter. 5.3 Notes on Wiring 5.3.1 Notes on Instrumentation...
Page 32 - round type insulated crimp-type terminal; Figure 5.1 Terminal Treatment of Power Cable, Current Output Cable
- 31 - 6F8A0883 5.4 Wiring 5.4.1 Terminal Treatment of Cables Follow the procedures below to treat the terminals (at the converter side) of various cables and install the cables to the terminal block. Use appropriate cables based on the description in Section 5.1 "Cables." Crimp a round type...
Page 33 - Figure 5.3 Terminal Treatment of Flow Rate Signal Cable; Notes on signal cable shield processing work; Figure 5.4 Treating the Signal Cable Shield Mesh
- 32 - 6F8A0883 (3) Connecting the input signal cable Strip the sheath from the end of each conductor of a 2-core individually shielded cable as shown in Figure 5.4. Twist those shields and cover them with a thermal contraction tube or vinyl tube not to make contact with the case or core wires. Then...
Page 34 - After connecting a cable, try to pull it to see whether it has
- 33 - 6F8A0883 5.4.2 Cable Connection Connect and install the terminal-treated cables to the terminal block. *Connect the cables to the terminal block securely. A loose connection may cause incorrect measurement. After connecting a cable, try to pull it to check whether it has been connected secure...
Page 35 - Preparatory check
- 34 - 6F8A0883 6. Operation Preparatory check Follow the procedure described below to prepare before starting the flow measurement (described with regard to the entire flowmeter). Check the items listed below Check the wiring between the converter and related instruments . Make sure all the bol...
Page 36 - Maintenance and Troubleshooting; Safety precaution for Maintenance and Troubleshooting
- 35 - 6F8A0883 7. Maintenance and Troubleshooting Safety precaution for Maintenance and Troubleshooting WARNING Do not disconnect while circuit is live unless location is known to be nonhazardous. DON’T Live part of electric circuit or a high temperature department can cause explosion . Do not ...
Page 37 - Cleaning; This reference
- 36 - 6F8A0883 7.1 Maintenance Cleaning Adhesion might be created in the detector over a long period of time when used on certain materials. Try to confirm whether to cause the adhesion in the detector pipe when the phenomenon is seen, and and an abnormality (ex. decreasing indication, etc.) is c...
Page 41 - Principle of Operation; Figure 8.1 Principle of Operation
- 40 - 6F8A0883 8. Principle of Operation The operating principle of the electromagnetic flowmeter is based on Faraday's Law of electromagnetic induction and it is designed to measure the volumetric flow rate of fluid. An insulated pipe of diameter D is placed vertically to the direction of a magnet...
Page 43 - Cable length:; Figure 9.1 Electrical Conductivity vs. Cable Length; Allowable cable len
- 42 - 6F8A0883 Connection flange standard: See Table 9.2 Type Specification Code. Principal materials Case Carbon steel Lining FEP (standard for meter sizes 15 to 250mm) PTFE (standard for meter sizes 300 to 600mm) Polyurethane (PU) (standard for meter sizes 15 to 400mm) Chloroprene rubber (CR) (st...
Page 45 - Figure 9.2 Flow volume; SI Unit
- 44 - 6F8A0883 To select the meter size: See Figure 9.2 and find meter sizes within the velocity of 0.1 to 10 m/s for a specified full-scale (measuring range high limit) flow. Select one that has its full-scale velocity between 1 and 3 m/s. Make sure the full-scale flow rate used for the final plan...
Page 46 - US Unit
- 45 - 6F8A0883 Flow velocity range Flow volume Meter size 0.328ft/s 0.98ft/s 3ft/s 10ft/s 32.8ft/s 1/2 inch 0.2801 gal/min 0.8403 gal/min 2.561 gal/min 8.538 gal/min 28.01 gal/min 1 inch 0.7781 gal/min 2.334 gal/min 7.115 gal/min 23.72 gal/min 77.81 gal/min 1 1/4 inch 1.275 gal/min 3.824 gal/min 11...
Page 47 - Type Specification Code; Table 9.2 Type Specification Code
- 46 - 6F8A0883 9.2 Type Specification Code Table 9.2 Type Specification Code Model number Specification code Lining 1 2 3 4 5 6 7 8 9 10 11 12 Contents G F 6 3 Flanged connection electromagnetic flowmeter detector PU CR FEP PTFE 0 2 Integral type Separate type ● ● ● ● ● ● ● ● 0 0 0 0 0 0 0 1 1 1 2 ...
Page 48 - Outline Dimensions
- 47 - 6F8A0883 10. Outline Dimensions 10.1 Outline dimensions of GF630/LF600F and GF630/LF610F (1) Meter size of 1/2 inch to 6 inch (15mm to 150mm) (1) Meter size of 1/2 inch to 8 inch (15mm to 200mm) NOTES (1) For the detail dimention of conveter, check the converter LF600F and LF610F instruction ...
Page 52 - Outline dimensions of Grounding ring
- 51 - 6F8A0883 10.3 Outline dimensions of Grounding ring Option for Polyurethan, CR and FEP *1) When the grounding ring will apply to the FEP lining, please attach the gasckets between the grounding ring and lining. (Refer to Fig 4.4.) Meter size ANSI 150 (Unit: inch) JIS 10K (Unit: mm) inch mm Φ D...
Page 53 - Appendix 1
- 52 - 6F8A0883 Appendix 1 1-1 A system block diagram for GF630/LF600F and GF630/LF610F
Page 54 - -2 A system block diagram for GF632
- 53 - 6F8A0883 1-2 A system block diagram for GF632