SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS A . Installation work and electrical wiring must bedone by qualified person(s) in accordance withall applicable codes and standards, includingfire-related construction. B . Sufficient air is needed for proper combustiona n d e x h a u s t i n g o ...
Page 3 - Figure 1; INTRODUCTION; GENERAL DESCRIPTION
Figure 1 Snorkel Filters Support Leg J-Box Top Cap Blower Assembly Wing Nuts INTRODUCTION GENERAL DESCRIPTION The complete Universal Cook‘n‘Vent ® System consists of the ventilator intake and a blower . See Fig. 1. The blower is either an integral (mounted on the vent intake in the cabinet under the...
Page 4 - PLAN THE INSTALLATION; Remote blower installation requires 5; Follow the duct installation guidelines in Table 2.; P a r t s N e e d e d f o r R e m o t e B l o w e r :
STEP 1 PLAN THE INSTALLATION Carefully follow the planning procedures listed below.See Figure 2. A . Determine whether a remote or integral blower willbe used. Remote blower installation requires 5 wires plus a ground wire to run from theCook‘n’Vent ® to the blower. B. Make sure adequate cabinet and...
Page 5 - Figure 2; Be certain to avoid interference; INTEGRAL
Figure 2 • Be certain to avoid interference with gas and electric supply tocooktop. • Shelving and drawer depths are dependent upon cooktop depthand setback. Page 4 10-3/8" 8-1/16" 12" 11" 11" 10" A B INTEGRAL REMOTE w/ CVT314 REMOTE w/ CVT7
Page 6 - FIGURES 3 THROUGH 6 ARE EXAMPLES OF POSSIBLE DUCTING; Figure 3; Figure 5; INTEGRAL BLOWER; Figure 6; REMOTE BLOWER; REMOTE BLOWER
FIGURES 3 THROUGH 6 ARE EXAMPLES OF POSSIBLE DUCTING Figure 3 THROUGH WALL INSTALLATION Figure 4 INTEGRAL BLOWER VTN600CVA Ground 12" Min. Wall CapWC8 Figure 5 THROUGH WALL DUCT INSTALLATION INTEGRAL BLOWER VTN600CVA BLOWER ROTATED 90° FOR SIDE CONNECTION THROUGH WALL INSTALLATION Figure 6 REMOT...
Page 9 - 0” Cooktops: Installed with UCV30; OW; INSTALLATION WITH THERMADOR COOKTOPS WHEN SPECIFIED; SB
Figure 7 TABLE 3 (in inches) UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS Table 3 Notes * Dimension "SB" is the minimum distance from the leading edge of the counter to the leading edge of the cutout. + + Dimension "BT" i s t h e t h i c k n e s s o f b a c k - s p l a...
Page 10 - If CCW is; smaller; than the UCV cutout width; I n s t a l l a t i o n; If CCW is larger than the UCV cutout width then:; Cut countertop using dims:; * Refer to Table 3 Notes on previous page.
I NSTALLATION WITH OTHER COOKTOPS WHERE SPECIFIED (SEE PART B) Figure 8 34-1/2" - UCV36 OW CW 28-1/2" - UCV30 1/8" OD CD SB 2-1/4" BT 43-1/2" - UCV45 The installer will need to have the cooktop installationinstructions available to complete the installation. Allcooktop dimensions...
Page 11 - PREPARE DUCT CUTOUTS IN CABINET; TABLE 4; INTEGRAL BLOWER VTN600CVA; B . Use Table 4 to layout the necessary cabinet; Figure 9; Plumb line to
STEP 3 PREPARE DUCT CUTOUTS IN CABINET TABLE 4 INTEGRAL BLOWER VTN600CVA C D E F G H UCV30 7 - 1 / 2 6 1 / 4 1 5 - 1 / 2 9 - UCV36 7 - 1 / 2 6 1 / 4 1 5 - 1 / 2 9 - UCV45 7 - 1 / 2 6 1 / 4 1 5 - 1 / 2 9 - REMOTE BLOWER VTR600R OR VTR1000Q C D E F G H UCV30 7 - 1 / 4 6 - 1 2 - 1 / 4 1 2 - 1 / 4 3 UCV...
Page 12 - Follow the; INSTALL ELECTRICAL SERVICE
STEP 6 MOUNT VENT & COOKTOP A. Remove grease filters and any packing materials frominside the intake. B. Set the vent intake into rear of countertop opening.Carefully lower it into position so that the flanges onthe rear sides and edges fully support the unit hangingfrom the countertop. C Loosel...
Page 13 - Wire to remote blower; Use spring type wire nuts supplied to con-; UCV WIRING DIAGRAM; R e d
STEP 7 MOUNT INTEGRAL BLOWER ORRemote Blower Transition MOUNT INTEGRAL BLOWER OR RemoteBlower Transition I n t e g r a l B l o w e r V T N 6 0 0 C V A O n l y A. Place blower in front of intake inside of cabinet,take conduit and blower wires and guide themtowards the right at the floor of the cabine...
Page 14 - NOTE: To prevent damage to any internal; Down button
STEP 8 VERIFY INSTALLATION,OPERATION & COOKTOPALIGNMENT Before performing this procedure, verify that allpacking materials were removed from inside thelower enclosure front and that the grease filtershave been properly installed. Refer to the Care andUse Manual for instructions regarding filter ...