Page 2 - WARRANTY / DAMAGE CLAIMS; No regular maintenance of the subwoofer is necessary.; UNPACKING- DAMAGE CLAIMS
2 WARRANTY / DAMAGE CLAIMS Congratulations on the purchase of your Tannoy 110 Series Subwoofer. No regular maintenance of the subwoofer is necessary. All Tannoy professional loudspeaker products are covered by a 5 year warranty for loudspeaker componentsand one year for electronic components from th...
Page 3 - 10 SERIES SUBWOOFERS AND INPUT MODULES
3 110 SERIES SUBWOOFERS AND INPUT MODULES This manual is intended for the owner, operator, or installer of Tannoy 110 series subwoofers . It is a guide forinstalling, setting up and operating the 110 series in accordance with established codes and practices available at thetime of publication. It do...
Page 4 - NOTES
Page 5 - TABLE OF CONTENTS
5 TABLE OF CONTENTS WARRANTY/DAMAGE CLAIMS TITLE PAGE CONTENTS CABINET OPTIONS 110TB (Tile Bridge) 110SR (Sheet Rock) 110CS (Corner Subwoofer) INPUT MODULE OPTIONS Pas s ive Cros s over Pas s ive 70 V Pas s ive 70 V Cros s over Active w/2 channel feed- through ACTIVE MODULE CONTROLS MECHANICAL INSTA...
Page 6 - CABINET OPTIONS
6 CABINET OPTIONS 110TB (Tile Bridge) Cabinet Simple yet sophisticated, the 110TB is the first product of its kind: a true ceilingmounted subwoofer. Engineered to deliver low frequency extension (-3 dB @31 Hz) and impact from a concealed ceiling mounted position, the 110TB inte-grates almost invisib...
Page 7 - INPUT MODULE OPTIONS; Cros s over
7 INPUT MODULE OPTIONS Pas s ive (standard) The basic connection panel supplied with any of the 110 Series subwoofers is an 8 Ohm speaker level input via barrierstrip. It is highly recommended that the audio signal be low pass filtered via an outboard active crossover. This inputmodule is ideal for ...
Page 8 - Pas s ive 70 Volt with crossover
8 INPUT MODULE OPTIONS Pas s ive 70 Volt Available for either option on passive units from page 7 A 70 Volt distribution amplifier is capable of supplying power to a number of remote speakers without concern of longcable runs or varied impedance loads (limited to amplifier power and line load). The ...
Page 10 - ACTIVE 110 INPUT MODULE CONTROLS; Active Module with output for 2 s peakers
10 ACTIVE 110 INPUT MODULE CONTROLS 120VAC - 60 Hz 1.25A 250 Volts Auto ON OFF INPUT HI PASS OUTPUT 1 1 0 S e r i e s PHASE O 180 LF BOOST O dB +4 dB EARTH LIFT GND LFT LOW PASS ALL PASS X-OVER FREQ 40Hz 150 Hz SUB LEVEL X-OVER MODE 813 Active Module with output for 2 s peakers 1 2 3 4 5 6 7 8 9 R L
Page 11 - order. Only available in 110SR and 110TB cabinet options.
11 ACTIVE 110 INPUT MODULE CONTROLS 1) INPUT - Two channel (stereo) balanced line level input. Connect via XLR male plugs from your signal source. Use high quality 2 conductor shielded audio cable (Belden 8451) for runs of up to 200'. The XLR pinout is: pin 1 (Shield),pin 2 (Signal high), pin 3 (Sig...
Page 12 - MECHANICAL INSTALLATION 110TB; NEW / EXISTING CONSTRUCTION INSTALLATION PROCEDURES:
12 MECHANICAL INSTALLATION 110TB NEW / EXISTING CONSTRUCTION INSTALLATION PROCEDURES: Before You Begin: Please read and understand all of these instructions thoroughly before beginning any work. Note that construction work for the installation of all Tannoy products must be done to local building co...
Page 13 - ’ x 2’ Tile Grid Installation Procedures:
13 MECHANICAL INSTALLATION 110TB 2’ x 2’ Tile Grid Installation Procedures: 1) The 110TB was designed for quick and simple installation directly into a 2’ x 2’ T-bar ceiling grid (Figs. 9 & 10). 2) Remove several tiles around the installation location to gain easier access for lacing the subwoof...
Page 16 - MECHANICAL INSTALLATION 110SR
16 MECHANICAL INSTALLATION 110SR NEW / EXISTING CONSTRUCTION INSTALLATION PROCEDURES: Before You Begin: Please read and understand all of these instructions thoroughly before beginning any work. Note that all construction work for the installation of all Tannoy products must be done to local buildin...
Page 20 - MECHANICAL INSTALLATION 110CS; INSTALLATION OF CORNER RAIL KIT
20 MECHANICAL INSTALLATION 110CS The 110CS subwoofer is easily installed in almost any indoor location where access to a corner is available. Although itsappearance is handsome in full view, the wide dispersion of its down firing woofer and the dispersion of low frequenciesin general, allow moderate...
Page 21 - SUBWOOFER INSTALLATION:
21 MECHANICAL INSTALLATION 110CS 1) At your desired location, establish a “ bottom” mark in the corner. For a minimum recommended space of 6”between the top of the subwoofer and the ceiling (to access the connector panel), this mark should fall at least20” from the ceiling. Extend a 20” level, horiz...
Page 23 - SIDE VIEW; SHIPPING WEIGHT WITH ACTIVE MODULE
23 DIMENSIONS 110TB .................................. .................................. .................................. .................................. .................................. .................................. .................................. .................................. ...
Page 25 - FRONT VIEW; PANEL; TOP VIEW
25 DIMENSIONS 110CS FRONT VIEW 17 1/2 " 22 7/8 " 10 1/2 " 13 3/8 " 30" PANEL TOP VIEW 14 1/2 " WA LL WA LL 7" SHIPPING WEIGHT WITH ACTIVE MODULE 56 LBS
Page 26 - TECHNICAL SPECIFICATIONS ACTIVE MODULE
26 TECHNICAL SPECIFICATIONS ACTIVE MODULE Frequency Response: -3 dB 31 Hz -150 Hz (-10 dB @ 21 Hz) Power Rating: 110 Watts rms Maximum SPL (2) @ 1 meter: 110 dB (Peak) Driver Complement: 1 x 10” (254 mm) LF Cutoff (- 3 dB): 31 Hz, 6 order tuning, vented box Inputs: 2 x XLR balanced Outputs: 2 x XLR ...