Supermicro AS 1020C-3 - Manuals
Supermicro AS 1020C-3 – Manual in PDF format online.
Manuals:
Manual Supermicro AS 1020C-3
Summary
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person...
Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the A+ Server 1020C-3. Instal- lation and maintainance should be performed by experienced technicians only. The 1020C-3 is a high-end 1U ra...
AS 1020C-3 User's Manual iv Chapter 4: System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the 1020C-3. Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed informat...
AS 1020C-3 User's Manual vi Table of Contents Preface About This Manual ...................................................................................................... iii Manual Organization ................................................................................................... i...
Power ...................................................................................................... 3-3 3-4 SAS Drive Carrier LEDs .................................................................................. 3-3 Chapter 4: System Safety 4-1 Electrical Safety Precautions .................
AS 1020C-3 User's Manual viii Fan Headers ............................................................................................ 5-15 Chassis Intrusion .................................................................................... 5-15 Power LED/Speaker .....................................
Table of Contents ix 6-3 System Fans .................................................................................................... 6-3 System Fan Failure ................................................................................... 6-3 Replacing System Cooling Fans ........................
Chapter 1: Introduction 1-1 Chapter 1 Introduction 1-1 Overview The AS1020C-3 is a high-end, dual processor 1U rackmount server system featur- ing some of the most advanced technology currently available. The 1020C-3 is comprised of two main subsystems: the SC813TQ+-500 1U rackmount chassis and the ...
AS1020C-3 User's Manual 1-2 1-2 Ser verboard Features At the hear t of the 1020C-3 lies the H8DCR-3 a dual processor ser verboard de- signed to provide maximum per formance. The H8DCR-3 is based on the nVidia nForce Pro 2200 and AMD-8132 chipset. Below are the main features of the H8DCR-3. See Figur...
Chapter 1: Introduction 1-3 ATI Graphics Controller An ATI video controller based on the Rage XL 8 MB graphics chip is integrated onboard the H8DCR-3. Rage XL fully suppor ts sideband addressing and AGP texturing. This onboard graphics package can provide a bandwidth of up to 512 MB /sec over a 32-b...
AS1020C-3 User's Manual 1-4 1-3 Ser ver Chassis Features The SC813TQ + - 500 is our third-generation 1U chassis and features four hot- swap SAS drive bays with SES2, a slim CD -ROM drive, a slim fl oppy drive and a revolutionar y cooling design that can keep today's power ful processors running well ...
Chapter 1: Introduction 1-5 Cooling System The SC813TQ + - 500 chassis' revolutionar y cooling design has been optimized to provide suf fi cient cooling for dual processor confi gurations. The chassis includes four counter-rotating 4 -cm fans located in the middle of the chassis. In the event of a fan...
AS1020C-3 User's Manual 1-6 1-4 Contacting Supermicro Headquarters Address: SuperMicro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: [email protected] (General Information) [email protected] (Technical Support) Web Site: www.s...
Chapter 2: Server Installation 2-1 Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your AS1020C-3 system up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This qui...
2-2 AS1020C-3 User's Manual Choosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). - Leave approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing. - This product...
Chapter 2: Server Installation 2-3 Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi - unit rack assembly, the ambient operating te m p e r at u r e of t h e r a c k e nv i r o n m e nt m ay b e g r e a te r t h a n t h e a m b i e n t temperature of the ro...
2-4 AS1020C-3 User's Manual Installing the Rack Rails Begin by joining one set of rack rails corresponding to either the left or the right side of the rack. Do this by aligning the studs of one rail with the holes of the other rail. Push the studs into the grooved holes and then push the rail to sli...
Chapter 2: Server Installation 2-5 Installing the Chassis Rails Two of the chassis rails (Chassis Rail 1) should have already been preattached - one to each side of the chassis. Attach the second set of chassis rails (Chassis Rail 2) directly to the chassis with the screws provided. Chassis Rail 2 s...
2-6 AS1020C-3 User's Manual Figure 2-3. Installing the Server into a Rack Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the ser ver into the rack. Do this by lining up the rear of the chassis rails with the f...
Chapter 2: Server Installation 2-7 Figure 2-4. Installing the Server into a Telco Rack Installing the Server into a Telco Rack If you are installing the 1020C-3 into a Telco type rack, follow the directions given on the previous pages for rack installation. The only dif ference in the installation p...
2-8 AS1020C-3 User's Manual 2-5 Checking the Serverboard Setup After you install the 1020C-3 in the rack, you will need to open the unit to make sure the ser verboard is properly installed and all the connections have been made. 1. Accessing the inside of the 1020C-3 (see Figure 2-5) First, release ...
Chapter 2: Server Installation 2-9 Figure 2-5. Accessing the Inside of the Server 2-6 Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the SAS drives have been properly installed and all connections have been made. 1. Accessing the drive bays All drives are ...
2-10 AS1020C-3 User's Manual 4. Check the airfl ow Airfl ow is provided by four sets of counter-rotating 4-cm fans. The system com- ponent layout was carefully designed to direct the airfl ow to the components that generate the most heat. Note that all power and data cables have been routed in such a w...
Chapter 3: System Interface 3-1 Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the SAS drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. There are als...
3-2 AS1020C-3 User's Manual 3-3 Control Panel LEDs The control panel located on the front of th SC813TQ + - 500 chassis has fi ve LEDs. These LEDs provide you with critical information related to dif ferent par ts of the system. This section explains what each LED indicates when illuminated and any c...
Chapter 4: System Safety 4-1 Chapter 4 System Safety ! Basic electrical safety precautions should be followed to protect yourself from harm and the 1020C-3 from damage: Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection...
AS1020C-3 User's Manual 4-2 4-2 General Safety Precautions Follow these rules to ensure general safety: Keep the area around the 1020C-3 clean and free of clutter. The 1020C-3 weighs approximately 38 lbs (17.3 kg) when fully loaded. When lifting the system, two people at either end should lift slowl...
Chapter 4: System Safety 4-3 4-3 ESD Precautions Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic com ponents and printed circ...
AS1020C-3 User's Manual 4-4 4-4 Operating Precautions Care must be taken to assure that the chassis cover is in place when the 1020C-3 is operating to ensure proper cooling. Out of warranty damage to the 1020C-3 system can occur if this practice is not strictly followed. ! Figure 4-1. Installing the...
Chapter 5: Advanced Serverboard Setup 5-1 Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the H8DCR-3 ser verboard, connect the data and power cables and install add- on cards. All ser verboard jumpers and connections are described a...
5-2 AS1020C-3 User's Manual 5-3 Processor and Heatsink Installation ! CPU Backplates Two CPU backplates (BKT-0004) have been preinstalled to the underside of the serverboard. These backplates prevent the CPU area of the serverboard from bending and provide a base for attaching the CPU heatsinks. Exe...
Chapter 5: Advanced Serverboard Setup 5-3 Installing the Processor 1. Lift the lever on CPU socket #1 until it points straight up. 2. Use your thumb and your index fi n- ger to hold the CPU. Locate pin 1 on the CPU socket and pin 1 on the CPU. Both are marked with a triangle. 3. Align pin 1 of the CP...
5-4 AS1020C-3 User's Manual Installing the Heatsinks To install the heatsink (SNK-P0012, optional), do not apply any thermal compound to the heatsink or CPU die - the proper amount has already been applied. Place the heatsink directly on the CPU so that the two mounting holes are aligned with those ...
Chapter 5: Advanced Serverboard Setup 5-5 5- 4 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the ser verboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The ribbon cab...
5-6 AS1020C-3 User's Manual Figure 5-2. Front Control Panel Header Pins (JF1) Connecting the Control Panel JF1 contains header pins for various front control panel connectors. See Figure 5 -2 for the pin locations of the various front control panel buttons and LED indica- tors and refer to section 5...
Chapter 5: Advanced Serverboard Setup 5-7 5-5 I /O Ports The I /O por ts are color coded in conformance with the PC 99 specifi cation. See Figure 5 -3 below for the colors and locations of the various I /O por ts. Figure 5-3. Rear Panel I/O Ports 5-6 Installing Memory CAUTION Exercise extreme care wh...
5-8 AS1020C-3 User's Manual Figure 5-4. Side and Top Views of DDR Installation To Install: Insert module vertically and press down until it snaps into place. The r e l e a s e t a b s s h o u l d close - if they do not you should close them yourself. To Remove: U s e y o u r t h u m b s t o gently p...
Chapter 5: Advanced Serverboard Setup 5-9 5-7 Adding PCI Cards 1. PCI slots The H8DCR-3 has two PCI-Express x8 slots, one 133 MHz PCI-X slot and one 100 MHz PCI-X expansion slots. Two riser cards are included with the ser ver to make two of these slots available in a 1U chassis format: one full heig...
5-10 AS1020C-3 User's Manual 5-8 Serverboard Details Figure 5-5. H8DCR-3 Serverboard Layout (not drawn to scale) Battery JBT1 Mouse SAS 4-7 VGA KB COM1 LAN2 LAN1 USB0/1 BIOS 1UIPMI JWOR JWD Speaker Rage XL JPG1 JI 2 C1 J22 Slot #6: 133 MHz PCI-X Slot #7: 100 MHz PCI-X (ZCR) AIC-9410W nVidia nForce P...
Chapter 5: Advanced Serverboard Setup 5-11 H8DCR-3 Quick Reference Jumpers Description Default Setting J3P 3rd Power Fail Detect En/Dis Closed (Enabled) JBT1 CMOS Clear See Section 2-7 JCF1 Compact Flash Select Closed (Master) JI 2 C1/2 I 2 C to PCI Enable/Disable Closed (Enabled) JPG1 VGA Enable/Di...
5-12 AS1020C-3 User's Manual 5-9 Connector Defi nitions ATX Power Connector The primary ATX power supply con- nector (J1B4) meets the SSI (Super- set ATX) 24-pin specifi cation. Refer to the table on the right for the pin defi ni- tions of the ATX 24-pin power connec- tor. This connection supplies powe...
Chapter 5: Advanced Serverboard Setup 5-13 Overheat/Fan Fail LED Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad- vanced warning of chassis overheat- ing. Refer to the table on the right for pin defi nitions and status indicators. NIC1 LED The NIC1 (Network Interface Control-...
Chapter 5: Advanced Serverboard Setup 5-15 Fan Headers The H8DCR-3/H8DR-i has fi ve fan headers, which are designated FAN1 through FAN5. Fans are Pulse Width Modulated (PWM) and their speed is controlled via Thermal Management with a BIOS setting. See the table on the right for pin defi nitions. Seria...
5-16 AS1020C-3 User's Manual ATX PS/2 Keyboard and PS/2 Mouse Ports T h e AT X P S / 2 k e y b o a r d a n d t h e PS/2 mouse ports are located on the backplane. The mouse is the green port. See the table on the right for pin defi nitions. PS/2 Keyboard and Mouse Port Pin Defi nitions Pin# Defi nition ...
Chapter 5: Advanced Serverboard Setup 5-17 Wake-On-LAN The Wake-On-LAN header is desig- nated JWOL. See the table on the right for pin defi nitions. You must have a LAN card with a Wake-On-LAN connector and cable to use the Wake- On-LAN feature. (*Note: Wake-On-LAN from S3, S4, S5 are supported by LA...
5-18 AS1020C-3 User's Manual Power Fail Connector Connect a cable from your power supply to JPWF to provide you with warning of a power supply failure. The warning signal is passed through the PWR_LED pin to indicate a power failure. See the table on the right for pin defi nitions. Power Fail Connect...
Chapter 5: Advanced Serverboard Setup 5-19 5-10 Jumper Settings Explanation of Jumpers To m o d i f y t h e o p e r a t i o n o f t h e ser ver board, jumpers c an be used to choose between optional settings. Jumpers create shor ts between two pins to change the func tion of the connector. Pin 1 is ...
5-20 AS1020C-3 User's Manual I 2 C to PCI Enable / Disable The JI 2 C1/2 pair of jumpers allows you to connect the System Management Bus to any one of the PCI expansion slots. The default setting is closed (on) for both jumpers to enable the connec- tion. Both connectors must be set the same (JI 2 C...
Chapter 5: Advanced Serverboard Setup 5-21 Watch Dog Enable/Disable JWD controls the Watch Dog function. Watch Dog is a system monitor that can reboot the system when a software application hangs. Jumping pins 1-2 will cause WD to reset the system if an application has frozen. Close pins 2-3 to have...
5-22 AS1020C-3 User's Manual PCI-X Slot Frequency Select Jumpers JPX1A and JPX2A can be used to change the speed of PCI-X slots 6 and 7, respectively. See the table on the right for jumper settings. PCI-X Slot Speed Jumper Settings (JPX1A/JPX2A) Jumper Setting Defi nition Open Auto Pins 1-2 PCI-X 66 ...
Chapter 5: Advanced Serverboard Setup 5-23 5-11 Onboard Indicators LAN1/LAN2 LEDs The Ethernet ports (located beside the VGA port) have two LEDs. On each Gb LAN port, the right LED (when facing the port) indicates activity while the left LED may be green, orange or off to indicate the speed of the c...
5-24 AS1020C-3 User's Manual 5-12 Floppy, IDE and SAS Connections Use the following information to connect the fl oppy and hard disk drive cables. The fl oppy disk drive cable has seven twisted wires. A red mark on a wire typically designates the location of pin 1. A single fl oppy disk drive ribbon ca...
Chapter 5: Advanced Serverboard Setup 5-25 IDE Connectors There are no jumpers to confi g- ure the onboard IDE#1 and #2 connectors. See the table on the right for pin defi nitions. IDE Drive Connectors Pin Defi nitions (JIDE#1/JIDE#2) Pin# Defi nition Pin # Defi nition 1 Reset IDE 2 Ground 3 Host Data 7 ...
5-26 AS1020C-3 User's Manual 5-13 Enabling SAS RAID After the hardware is set up, you should install the operating system and the SAS RAID drivers, you may wish to confi gure a RAID array with your SAS drives. This section gives an outline of the Adaptec SAS Utility program and instructions for creat...
Chapter 5: Advanced Serverboard Setup 5-27 SAS Controller Utility You are now in the SAS Controller Utility program. In this utility, you can create, confi gure, manage and delete RAID arrays. Navigating through the utility is done by using the arrow keys on your keyboard to move between fi elds. The ...
5-28 AS1020C-3 User's Manual Figure 5-8. Array Confi guration Utility Screen
Chapter 5: Advanced Serverboard Setup 5-29 4. Once all drives have been selected for the RAID array, you will be prompted to select the RAID properties, including the type of RAID to be used, label, array size and stripe size (see Figure C-5). When the properties have been defi ned, highlight Done an...
5-30 AS1020C-3 User's Manual Figure 5-10. Driver/Tool Installation Display Screen Click the icons showing a hand writing on paper to view the readme fi les for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After installing...
Chapter 6: Advanced Chassis Setup 6-1 Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC813TQ+-500 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered...
Chapter 6: Advanced Chassis Setup 6-3 6-3 System Fans Four high-performance, counter-rotating 4-cm fans provide all the cooling needed for the 1020C-3. Each fan is actually made up of two fans joined back-to-back that rotate in opposite directions. This counter-rotating action generates exceptional ...
6-4 AS1020C-3 User's Manual Figure 6-2. System Cooling Fans 6-4 Drive Bay Installation/Removal Removing the Front Bezel If your system has a front bezel (optional) attached to the chassis, you must fi rst remove it to gain access to the drive bays. To remove the bezel, fi rst unlock the front of the c...
Chapter 6: Advanced Chassis Setup 6-5 Accessing the Drive Bays SAS Drives: Because of their hotswap capability, you do not need to access the inside of the chassis or power down the system to install or replace SAS drives. Proceed to the next step for instructions. CD-ROM/Floppy Disk Drives: For ins...
6-6 AS1020C-3 User's Manual Serial Attached SCSI (SAS) Drive Installation 1. Mounting a SAS drive in a drive carrier The SAS drives are mounted in drive carriers to simplify their installation and re- moval from the chassis. These carriers also help promote proper airfl ow for the SAS drive bays. For...
Chapter 6: Advanced Chassis Setup 6-7 SAS Power Cables SAS power cables should be routed so that they do not block the airfl ow through the chassis. See the motherboard layout diagram for the location of the cable connections. SAS Backplane The SAS drives plug into a backplane that provides power, dr...
6-8 AS1020C-3 User's Manual CD-ROM and Floppy Drive Installation The top cover of the chassis must be opened to gain full access to the CD-ROM and fl oppy drive bays. The 1020C-3 accomodates only slim-line CD-ROM drives. Side mounting brackets are needed to mount a slim-line CD-ROM drive in the 1020C...
Chapter 6: Advanced Chassis Setup 6-9 6-5 Power Supply The 1020C-3 has a single 500 watt power supply, which is auto-switching capable. This enables it to automatically sense and operate at a 100v to 240v input voltage. An amber light will be illuminated on the power supply when the power is off. An...
Chapter 7: BIOS 7-1 Chapter 7 BIOS 7-1 Introduction This chapter describes the AMIBIOS™ Setup utility for the H8DCR-3. The AMI ROM BIOS is stored in a fl ash chip and can be easily upgraded using a fl oppy disk-based program. Note: Due to periodic changes to the BIOS, some settings may have been added...
7-2 AS1020C-3 User's Manual 7-2 Main Menu When you fi rst enter AMI BIOS Setup Utility, you will see the Main Menu screen. You can always return to the Main Menu by selecting the Main tab on the top of the screen with the arrow keys. The Main Menu screen provides you with a system overview, which inc...
Chapter 7: BIOS 7-3 Primary/Secondary IDE Master/Slave Highlight one of the items above and press <Enter> to access the submenu for that item. The same settings apply to the Secondary through Sixth IDE sevices. Type Select the type of device connected to the system. The options are Not Install...
Chapter 7: BIOS 7-5 Confi guration nVidia RAID ROM RAID Option ROM This setting is used to Enable or Disable the nVidia ROM. If enabled, the set- ting below will appear. Master SATA as RAID This setting is used to set the third master as a RAID drive. The options are Enabled or Disabled . Floppy Confi...
7-6 AS1020C-3 User's Manual Allocate IRQ to PCI VGA Set this value to allow or restrict the system from giving the VGA adapter card an interrupt address. The options are Yes and No. Palette Snooping Select "Enabled" to inform the PCI devices that an ISA graphics device is installed in the sy...
7-8 AS1020C-3 User's Manual DRAM BG Scrub Corrects memory errors so later reads are correct. Options are Dis- abled and various times in nanoseconds and microseconds. L2 Cache BG Scrub Allows L2 cache RAM to be corrected when idle. Options are Disabled and various times in nanoseconds and microsecon...
Chapter 7: BIOS 7-9 PCI Express Spread Spectrum This setting is used to enable spread spectrum for the PCI Express. Options are Disabled and Down Spread. Primary Video This setting is used to switch the PCI bus scanning order while searching for the video card. It allows the user to select the type ...
7-10 AS1020C-3 User's Manual Parallel Port Address This option specifi es the I/O address used by the parallel port. Select Disabled to prevent the parallel port from accessing any system resources. When the value of this option is set to Disabled, the printer port becomes unavailable. Select 378 to ...
Chapter 7: BIOS 7-11 AMD PowerNow Confi guration This setting is used to Enable or Disable the AMD PowerNow feature. DMI Event Logging View Event Log Highlight this item and press <Enter> to view the contents of the event log. Mark All Events as Read Highlight this item and press <Enter> ...
7-12 AS1020C-3 User's Manual Terminal Type This item allows you to select the terminal type for console redirection. The options are ANSI , VT100, and VT-UTF8. VT-UTF8 Combo Key Support This item allows you to Enable or Disable VT-UTF8 combo key support. Sredir Memory Display Delay This item allows ...
7-14 AS1020C-3 User's Manual USB Confi guration This screen will display the module version and all USB enabled devices. USB Controller Support Enable the controller for your USB ports. Options are Disabled, USB 1.1 only and USB 1.1 + USB 2.0 . Legacy USB Support Select "Enabled" to enable th...
Chapter 7: BIOS 7-15 7-4 Boot Menu This feature allows the user to confi gure the following items: Boot Settings Confi guration Quick Boot If Enabled, this option will skip certain tests during POST to reduce the time needed for the system to boot up. The options are Enabled and Disabled. Quiet Boot I...
7-16 AS1020C-3 User's Manual Interrupt 19 Capture Enable to allow ROMs to trap Interrupt 19. The options are Enabled and Dis- abled . Boot Device Priority This feature allows the user to prioritize the sequence for the boot device from all available devices. Removeable Drives This feature allows the...
Chapter 7: BIOS 7-17 7-6 Exit Menu Select the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Save Changes and Exit When you have completed the system confi guration changes, select this option to leave BIOS Setup and reboot the computer, so the new system confi gurati...
Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the scree...
B-1 Appendix B: BIOS POST Checkpoint Codes Appendix B BIOS POST Checkpoint Codes When AMIBIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, diagnostic equipment can be attached to the computer to read I/O port 0080h. ...
B-2 AS1020C-3 User’s Manual Checkpoint Code Description E0h The onboard fl oppy controller if available is initialized. Next, beginning the base 512 KB memory test. E1h Initializing the interrupt vector table next. E2h Initializing the DMA and Interrupt controllers next. E6h Enabling the fl oppy drive...
B-3 Appendix B: BIOS POST Checkpoint Codes Checkpoint Code Description 03h The NMI is disabled. Next, checking for a soft reset or a power on condition. 05h The BIOS stack has been built. Next, disabling cache memory. 06h Uncompressing the POST code next. 07h Next, initializing the CPU and the CPU d...
C-3 Appendix C: System Specifi cations Regulatory Compliance Electromagnetic Emissions: FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR 22 Class B Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) S...
Supermicro Manuals
-
Supermicro X7DBi+
Manual
-
Supermicro MBDX7DA3O
Manual
-
Supermicro H8QM3-2
Manual
-
Supermicro 5016T-TB
Manual
-
Supermicro X8SIL
Manual
-
Supermicro X9DRD-iF
Manual
-
Supermicro SUPER
Manual
-
Supermicro H8QMI-2
Manual
-
Supermicro SAS-826A
Manual
-
Supermicro X8DTU-6TF+-LR
Manual
-
Supermicro X8DTE
Manual
-
Supermicro X7SPE-HF-D525
Manual
-
Supermicro 6016XT-TF
Manual
-
Supermicro 5014C-T
Manual
-
Supermicro 5015M-NTR
Manual
-
Supermicro 5010E
Manual
-
Supermicro SUPER X5DLR-8G2
Manual
-
Supermicro SC512
Manual
-
Supermicro C2SEA
Manual
-
Supermicro X7SPA-H-D525
Manual