Summary
A+ Server 1022G-URF User's Guide ii Manual Revision 1.0e Release Date: March 06, 2014 The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitmen...
iii Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the A+ SERVER 1022G-URF. Installation and maintenance should be performed by experienced technicians only. The A+ SERVER 1022G-...
A+ Server 1022G-URF User's Guide iv Chapter 5: Advanced Serverboard Setup This chapter provides detailed information on the H8DGU-F serverboard, including the locations and functions of connectors, headers and jumpers. Refer to this chap-ter when adding or removing processors or main memory and when...
v Preface Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-11-2 Serverboard Features ..................................................................................... 1-2Processors ..............
vii Preface Chapter 5 Advanced Serverboard Setup 5-1 Handling the Serverboard ............................................................................... 5-1Precautions ..................................................................................................... 5-1Unpacking ...............
1-2 A + SE R VER 1022G-URF User's Manual • Product safety information: http://super-dev/about/policies/safety_information.cfm For support, email [email protected]. 1-2 Serverboard Features At the heart of the A+ SERVER 1022G-URF lies the H8DGU-F, a dual processor serverboard based on the AMD SR...
1-3 Chapter 1: Introduction Note: You must have RAID set up to enable the hot-swap capability of the SATA drives. Documentation on RAID setup guidelines can be found on our web site. Onboard Controllers/Ports The color-coded I/O ports include two COM ports (one header and one port), a VGA (monitor) ...
1-5 Chapter 1: Introduction Figure 1-1. AMD SR5670/SP5100 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. AMD Socket G34 CPU2 DIMM A0 DIMM A1 DIMM A1 DIMM A0 HT3 Link (8+8)x(8+8)-3.2GT/s HT3 Link 16x16-5.2GT/s HT3 Link 16x16-3.2GT/s DIMM B0 DIMM...
1-6 A + SE R VER 1022G-URF User's Manual 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer, Inc.980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: [email protected] (General Information)[email protected] (Technical Support) Web...
Chapter 2: Server Installation 2-1 Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your A+ SERVER 1022G-URF up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This ...
2-2 A+ S ERVER 1022G-URF User's Manual installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display ...
Chapter 2: Server Installation 2-3 Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be gi...
2-4 A+ S ERVER 1022G-URF User's Manual 2-5 Installing the System into a Rack This section provides information on installing the 1022G-URF into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-6 and 2-7.There are a variety...
Chapter 2: Server Installation 2-5 Installing the Outer Rails Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail. Adjust both the short and long...
2-6 A+ S ERVER 1022G-URF User's Manual Figure 2-3. Installing the Server into a Rack Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails ...
Chapter 2: Server Installation 2-7 Figure 2-4. Installing the Server into a Telco Rack Installing the Server into a Telco Rack To install the 1022G-URF into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend...
2-8 A+ S ERVER 1022G-URF User's Manual 2-6 Checking the Serverboard Setup After you install the 1022G-URF in the rack, you will need to open the top cover to make sure the serverboard is properly installed and all the connections have been made. Accessing the Inside of the System 1. First, grasp the...
Chapter 2: Server Installation 2-9 Figure 2-5. Accessing the Inside of the System 2-7 Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the SATA drives and SATA backplane have been properly installed and all connections have been made. Checking the Drives All...
Chapter 3: System Interface 3-1 Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the SAS/SATA drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components. There ar...
3-2 A + SE R VER 1022G-URF User's Manual Power The main power button is used to apply or remove power from the power supply to the server system. Turning off system power with this button removes the main power but keeps standby power supplied to the system. 3-3 Control Panel LEDs The control panel ...
Chapter 3: System Interface 3-3 NIC2 Indicates network activity on LAN2 when flashing. 2 1 Note: deactivating the UID LED must be performed in the same way it was activated. (If the UID LED was activated via IPMI, you can only turn the LED off via IPMI and not with the UID button.) NIC1 Indicates ne...
3-4 A + SE R VER 1022G-URF User's Manual 3-4 Hard Drive Carrier LEDs Each hard drive carrier has two LEDs. • Green: When illuminated, the green LED on the front of the drive carrier in- dicates drive activity. A connection to the drive backplane enables this LED to blink on and off when that particu...
4-1 Chapter 4: Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems 4-1 About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you ...
4-4 A+ Server 1022G-URF User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. WarnungVor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalaci...
4-5 Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキット・ブレーカー この製品は、短絡(過電流)保護装置がある建物での設置を前提としています。 保護装置の定格が...
4-6 A+ Server 1022G-URF User's Manual Power Disconnection Warning 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセス するには、 システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り 外す必要があります。 警告 在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。 警告 在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。 Warnung Das System muss von allen Quellen der Energ...
4-7 Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Atte...
4-8 A+ Server 1022G-URF User's Manual Equipment Installation 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可 されています。 Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte...
4-9 Chapter 4: Warning Statements for AC Systems アクセス制限区域 このユニットは、アクセス制限区域に設置されることを想定しています。 アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いての み出入りが可能です。 Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool,...
4-10 A+ Server 1022G-URF User's Manual Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions ...
4-12 A+ Server 1022G-URF User's Manual Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden. ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para ...
4-13 Chapter 4: Warning Statements for AC Systems Backplane Voltage バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。 修理する際には注意ください。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen ...
4-14 A+ Server 1022G-URF User's Manual Comply with Local and National Electrical Codes Warning! Installation of the equipment must comply with local and national electrical codes. 地方および国の電気規格に準拠機器の取り付けはその地方および国の電気規格に準拠する必要があります。 Warnung Die Installation der Geräte muss den Sicherheitsstandards entsp...
4-15 Chapter 4: Warning Statements for AC Systems Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations. יצראה למשחה יקוח םואית !הרהזא תנקתה םייצראהו םיימוקמה למשחה יקוחל תמאות תויהל תבייח דויצה . تادعملا بيكرت ةيئابرهكلا لل لثتم...
4-16 A+ Server 1022G-URF User's Manual Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention...
4-17 Chapter 4: Warning Statements for AC Systems WarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelt...
4-18 A+ Server 1022G-URF User's Manual Warning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the use of UL o...
4-19 Chapter 4: Warning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et de loi sur la sécurité Ma...
Chapter 5: Advanced Serverboard Setup 5-1 Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the H8DGU-F serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and ...
5-2 A + SE R VER 1022G-UTF User's Manual 5-2 Processor and Heatsink Installation Installing the Processors 1. Begin by removing the cover plate that protects the CPU. Lift the lever on the CPU socket until it points straight up. 2. With the lever raised, lift open the silver CPU retention plate. Not...
Chapter 5: Advanced Serverboard Setup 5-3 Triangle 3. Use your thumb and your index finger to hold the CPU. Locate and align pin 1 of the CPU socket with pin 1 of the CPU. Both are marked with a triangle. 4. Align pin 1 of the CPU with pin 1 of the socket. Once aligned, carefully place the CPU into ...
5-4 A + SE R VER 1022G-UTF User's Manual Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die -- the re- quired amount has already been applied. 2. Place the heatsink directly on top of the CPU so that the heat sink screws are aligned with the mounting ...
Chapter 5: Advanced Serverboard Setup 5-5 5-3 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The cables used ...
Chapter 5: Advanced Serverboard Setup 5-7 5-5 Installing Memory Figure 5-3. Installing DIMM into Slot CAUTION! Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Memory Support The H8DGU-F supports up to 512 GB of DDR3-1333/1066/800MHz registered ECC SDRAM...
5-8 A + SE R VER 1022G-UTF User's Manual Memory Population for Optimal Performance -For a Motherboard with One CPU (CPU1) Installed # DIMMS CPU Branch 0 Branch 1 Branch 2 Branch 3 2 DIMMs CPU1 P1-1A P1-2A 4 DIMMs CPU1 P1-1A P1-2A P1-3A P1-4A 8 DIMMs CPU1 P1-1A P1-1B P1-2A P1-2B P1-3A P1-3B P1-4A P1-...
Chapter 5: Advanced Serverboard Setup 5-9 Possible System Memory Allocation & Availability System Device Size Physical Memory Available (4 GB Total System Memory) Firmware Hub flash memory (System BIOS) 1 MB 3.99 GB Local APIC 4 KB 3.99 GB Area Reserved for the chipset 2 MB 3.99 GB I/O APIC (4 K...
5-10 A + SE R VER 1022G-UTF User's Manual 5-6 Adding PCI Cards PCI Expansion Slots A riser card is used to support an add-on card to the system and comes pre-installed. Installing a PCI Expansion Card 1. Remove the chassis cover. 2. Install the riser card by sliding card into the appropriate slot in...
Chapter 5: Advanced Serverboard Setup 5-11 Figure 5-4. SUPER H8DGU-F Layout (not drawn to scale) 5-7 Serverboard Details JD1 JPW1 JF1 JI2C1 JI2C2 JOH1 JL1 JWF1 JPL1 JWD JPG1 FAN3 FAN8 FAN2 FAN1 FAN7 FAN4 FAN5 FAN6 LE1 UIOP JPW2 JPW3 IP MB JPI2C DP2 BATTERY SATA5 SATA0 SATA1 SATA2 SATA3 SATA4 T-SGPIO...
Chapter 5: Advanced Serverboard Setup 5-13 5-8 Connector Definitions Power Connectors A 24-pin main power supply connector(JPW1) and three 8-pin CPU PWR connectors (JPW2/JPW3/JPW4) on the motherboard. These power connectors meet the SSI EPS 12V specification. In addition to the 24-pin ATX power conn...
Chapter 5: Advanced Serverboard Setup 5-15 Universal Serial Bus Ports Two Universal Serial Bus ports (USB 2.0) are located beside the Keyboard and Mouse PS2 ports. One additional Type A port (USB6) is included on the motherboard. See the table on the right for pin definitions. Universal Serial Bus P...
Chapter 5: Advanced Serverboard Setup 5-17 ATX PS/2 Keyboard and PS/2 Mouse Ports The ATX PS/2 keyboard and PS/2 mouse are located next to the Back Panel USB Ports 0~3 on the motherboard. See the table at right for pin definitions. PS/2 Keyboard/Mouse Pin Definitions PS2 Keyboard PS2 Mouse Pin# Defi...
5-18 A + SE R VER 1022G-UTF User's Manual UID Button Pin Definitions Pin# Definition 1 Ground 2 Ground 3 Button In 4 Ground Unit Identifier Button In addition to the UID (Unit Identifier) button on the rear I/O panel, there is another UID button located on the control panel. When you push either UID...
Chapter 5: Advanced Serverboard Setup 5-19 5-9 Jumper Settings Explanation of Jumpers To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts be-tween two pins to change the function of the connector. Pin 1 is identified with a squar...
5-20 A + SE R VER 1022G-UTF User's Manual VGA Enable/Disable JPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2 to enable VGA. See the table on the right for jumper settings. VGA Enable/Disable Jumper Settings (JPG1) Jumper Setting Definition Pins 1-2 Enabled ...
Chapter 5: Advanced Serverboard Setup 5-21 5-10 Onboard Indicators LAN1/LAN2 LEDs The Ethernet ports (located beside the VGA port) have two LEDs. On each Gb LAN port, one LED blinks to indicate activity while the other may be green, amber or off to indicate the speed of the connection. See the table...
5-22 A + SE R VER 1022G-UTF User's Manual 5-11 SATA Drive Connections SATA Ports There are no jumpers to configure the SATA ports, which are designated SATA0 through SATA5. See the table on the right for pin definitions. SATA Ports Pin Definitions (SATA0-SATA3) Pin # Definition Pin # Definition 1 Gr...
Chapter 5: Advanced Serverboard Setup 5-23 5-12 Enabling SATA RAID Now that the hardware is set up, you must install the operating system and the SATA RAID drivers, if you wish to use RAID with your SATA drives. The installation procedure differs depending on whether you wish to have the operating s...
5-24 A + SE R VER 1022G-UTF User's Manual Figure 5-5. BIOS Setup Screen Enabling SATA RAID in the BIOS Before installing the Windows operating system, you must change some settings in the BIOS. Boot up the system and hit the <Delete> key to enter the BIOS Setup Utlility. After the setup utilit...
Chapter 5: Advanced Serverboard Setup 5-25 Figure 5-7. Adaptec RAID Utility Program Screen Using the DotHill and Adaptec RAID Utility The RAID Utility program allows you to define the drives you want to include in the RAID array and the mode and type of RAID. Figure 5-6. DotHill RAID Utility Program...
5-26 A + SE R VER 1022G-UTF User's Manual Installing the RAID Driver During OS Installation You may also use the procedure below to install the RAID driver during the Win-dows OS installation: 1. With the Windows OS installation CD-ROM in the CD drive, restart the sys- tem. 2. Press <Enter> ag...
Chapter 5: Advanced Serverboard Setup 5-27 Note: Click the icons showing a hand writing on paper to view the readme files for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After installing each item, you must reboot the s...
Chapter 5: Advanced Serverboard Setup 5-29 5-14 Serverboard Battery Caution : There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 5-11). This battery must be re-placed only with the same or an equivalent type recommended by the...
Chapter 6: Advanced Chassis Setup 6-1 Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the 815TS-R700UBP chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered....
Chapter 6: Advanced Chassis Setup 6-3 System Fan Failure Fan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining fan will ramp up to full speed and the overheat/fan fail LED on the control panel will turn on. Replace any failed fan at your earliest convenience...
6-4 A + SE R VER 1022G-URF User's Manual Accessing the Drive Bays Hard Drives: Because of their hotswap capability, you do not need to access the inside of the chassis or power down the system to install or replace SATA drives. Proceed to the next section for instructions.DVD-ROM Drive: For installi...
Chapter 6: Advanced Chassis Setup 6-5 Use caution when working around the hard drive backplane. Do not touch the backplane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes, which aid in proper airflow.Important: Regardless of how many hard drives are in...
6-6 A + SE R VER 1022G-URF User's Manual Installing/Removing a Hard Drive 1. To remove a carrier, push the release button located beside the drive LEDs. 2. Swing the colored handle fully out and use it to pull the unit straight out (see Figure 6-5). Note: Your operating system must have RAID support...
Chapter 6: Advanced Chassis Setup 6-7 2. Depress the two buttons on the top of the chassis to release the top cover and at the same time, push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server. Removing/Installing...
Chapter 7: BIOS 7-1 Chapter 7 BIOS 7-1 Introduction This chapter describes the AMI BIOS Setup Utility for the A+ SERVER 1022G-URF. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens. Starting...
A+ Server 1022G-URF User's Manual 7-2 System Time/System Date You can edit this field to change the system time and date. Highlight System Time or System Date using the <Arrow> keys. Enter new values through the keyboard. Press the <Tab> key or the <Arrow> keys to move between fiel...
Chapter 7: BIOS 7-3 Watch Dog Function Allows system to restart when system is inactive more than 5-minutes. The options are Enabled and Disabled . Power Button Function This sets the function of the power button when you turn off the system. Options include 4-second Overide and Instant Off . Restor...
A+ Server 1022G-URF User's Manual 7-4 Power Cap This option can decide the highest P-state in the OS. Options include P-state 0 through P-state 4. ACPI SRAT Table This option Enables or Disables the building of the ACPI SRAT Table. CPU Down Core This option sets down core support for the CPU. Option...
Chapter 7: BIOS 7-5 Bank Swizzle Mode This setting Enables or Disables the bank swizzle mode. ECC Configuration ECC Mode This submenu affects the DRAM scrub rate based on its setting. Options include Disabled, Basic , Good, Super, Max and User. Selecting User activates the other options for user s...
A+ Server 1022G-URF User's Manual 7-6 Legacy USB Support Select "Enabled" to enable the support for USB Legacy. Disable Legacy support if there are no USB devices installed in the system. "Auto" disabled Legacy support if no USB devices are connected. The options are Disabled, Enable...
Chapter 7: BIOS 7-9 I/O port address and IRQ 4 for the interrupt address. Options include Disabled, 3F8/IRQ4 , 3E8/IRQ4 and 2E8/IRQ3 Serial 2 Address This option specifies the base I/O port address and Interrupt Request address of serial port 2. Select "Disabled" to prevent the serial port f...
Chapter 7: BIOS 7-11 ACPI APIC Support Determines whether to include the ACPI APIC table pointer in the RSDT pointer list. The available options are Enabled and Disabled. Headless Mode Use this setting to Enable or Disable headless operation mode through ACPI. ACPI Version Features Use this setting ...
A+ Server 1022G-URF User's Manual 7-12 IP Address This submenu sets the IP address source as either Static or DHCP. Selecting Static allows you to manually set the IP Address, Subnet Mask and Gateway Address. In the field provided here enter the IP address in the decimal form of xxx.xxx.xxx.xxx with...
Chapter 7: BIOS 7-13 SR56x0 (RD890S) PCIE Error Log This setting allows you set an error log ofr PCIE errors. Options include Yes or No . 7-4 Security Menu AMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set first. Change Supervisor Pass...
A-1 Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error...
Appendix B: Installing Windows B-1 Appendix B Installing Windows After all hardware components have been installed, you must first configure Intel South Bridge RAID Settings before you install the Windows OS and other software drivers. To configure RAID settings, please refer to RAID Configuration U...
B-2 A + SE R VER 1022G-URF User's Manual 9. From the Windows XP/Windows 2003 Setup screen, press the <Enter> key. The XP/2003 Setup will automatically load all device files and then, continue the Windows XP/Windows 2003 installation. 10. After the Windows XP/Windows 2003 OS Installation has co...
Appendix C: System Specifications C-1 Appendix C System Specifications Processors Dual AMD Opteron 6000 series (AMD Socket G34 type) processors Note: You must install at least two processors for full functions to be supported. Note: Please refer to our web site for a complete listing of supported pr...
Appendix C: System Specifications C-3 Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class AElectromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)Saf...
Supermicro Manuals
-
Supermicro X7DBi+
Manual
-
Supermicro MBDX7DA3O
Manual
-
Supermicro H8QM3-2
Manual
-
Supermicro 5016T-TB
Manual
-
Supermicro X8SIL
Manual
-
Supermicro X9DRD-iF
Manual
-
Supermicro SUPER
Manual
-
Supermicro H8QMI-2
Manual
-
Supermicro SAS-826A
Manual
-
Supermicro X8DTU-6TF+-LR
Manual
-
Supermicro X8DTE
Manual
-
Supermicro X7SPE-HF-D525
Manual
-
Supermicro 6016XT-TF
Manual
-
Supermicro 5014C-T
Manual
-
Supermicro 5015M-NTR
Manual
-
Supermicro 5010E
Manual
-
Supermicro SUPER X5DLR-8G2
Manual
-
Supermicro SC512
Manual
-
Supermicro C2SEA
Manual
-
Supermicro X7SPA-H-D525
Manual