Page 2 - TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION
2 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New York City Approval .....................Page 4Cold C...
Page 3 - 0 - latest edition, or the Canadian Electrical; Table 1
3 The appliance, when installed, must be electri- cally grounded and wired in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition, or the Canadian Electrical Code, CSA C22.1 - latest edition. Provide adequate clearances arou...
Page 4 - Table 3; Flame Height; SIT Millivolt Gas Valve; NOTE: Flame appearance will diminish 4% per; REQUIREMENTS FOR THE COMMON-; Table 5
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 4 Gas Pressure - All Models Tables 3 and 4 show the appliances' gas pressure requirements: Inlet Gas Supply Pressure (all models) Fuel # Minimum Maximum Natural Gas 5.0" WC (1.24 kPa) 10.5" WC (2.61 kPa) Propane 11.0" WC (2.74 kPa) 1...
Page 5 - Figure 3 - Typical Locations; Do not insulate the space between the ap-
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 5 LOCATION In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important. Due to high temperatures, the appliance ...
Page 6 - VENT TERMINATION CLEARANCES; These instructions should be used as a; Vertical Vent Termination Clearances; Termination Heights For Vents; Figure 5; Horizontal Vent Termination Clearances; Side Elevation View; Minimum; Figure 4A - Multiple Terminations
6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 6 12 X Roof Pitch is X/12 2 FT MIN. 2 FT MIN. Lowest Discharge Opening H* *H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS Horizontal Overhang Vertical Wall Vent Terminati...
Page 7 - EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Figure 6; Minimum Clearances
7 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS Figure 6 Minimum Clearances Canadian Installation * US Installation ** A = Clearance above grade, veranda, porch, deck or balcony. 12 inches (30 cm) * 12 inches (30 cm) ** B = Clearance...
Page 8 - MINIMUM CLEARANCES TO COMBUSTIBLES; When the; inclined vent component.; Table 6; The material must; . Maintain the minimum height from appliance base to the underside; Figure 7
8 5 (127) 8-1/4 (209) 14 (356) 12 (305) 19 (483) MINIMUM CLEARANCES TO COMBUSTIBLES Maintain clearances from appliance to combustible materials as detailed in Table 6, with the following exception: When the appliance is installed with one side flush with a wall, the wall on the other side of the app...
Page 9 - DETAILED INSTALLATION STEPS; Removing Glass Panels on Page 30.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 9 Figure 10 REMOVE CARDBOARD BEFORE USING REMOVE CARDBOARD BEFORE USING Pressure Relief Plates Remove Cardboard Before Using Appliance DETAILED INSTALLATION STEPS TYPICAL INSTALLATION SEQUENCE The typical sequence of installation is outlined below...
Page 11 - FLUE; Model
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 11 Figure 13 FIREPLACE SPECIFICATIONS - SSDVPF (PENINSULA VIEW) Fireplace Framing Specifications 12 (305) 10 (254) 40-1/8 (1019) 3-1/2(89) (16) FRAMING SPACERS (Top and Side) FINISH WALL BRACKET (Front, back, and left edge of unit top) 6-7/8 (175)...
Page 12 - Proper Sizing of Gas Line; Table 7; Step 2. ROUTING GAS LINE
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Also see Figures 12 and 13 on Pages 10 and 11 5-5/8" (143 mm) 3-1/8" (79 mm) Figure 14 - ROUTE GAS LINE Proper Sizing of Gas Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is t...
Page 13 - The VENT SEAL CAP must remain securely installed; Note: The restrictor is included within the firebox.; Step 3. INSTALL THE VENT SYSTEM; Approved Vent; on
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 13 Securing Screws (OUTSIDE OF APPLIANCE) Insulation Top Vent Vent Seal Cap Firebox Top Cabinet Top CROSS SECTION SIDE VENT SEAL CAP REMOVAL (SIDE VENT INSTALLATIONS ONLY) Insulation Vent Seal Cap Securing Screws Side Vent Cabinet Back CROSS SECTI...
Page 14 - Table 8; and 18) and their associated Vertical Vent Tables
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 14 Figure 18 SV4.5CGV-1 Termination SV4.5FA or SV4.5FB Flashing and SV4.5SC Storm Collar 1” (25.4 mm) Minimum Clearance to Combustibles u SV4.5VF Firestop / spacer SV4.5L6 / 12 / 24 / 36 / 48 Vent Sections u When using Secure Flex use Firestop / s...
Page 17 - Ratio V to H ratio is 1:2; VERTICAL VENT FIGURES/TABLES; rate sections of concentric flexible
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 17 H V V1 V H Table A H Maximum V Minimum feet (meter) feet (meter) 2 (0.610) 1 (0.305) 4 (1.219) 2 (0.610) 6 (1.829) 3 (0.914) 8 (2.438) 4 (1.219) V + H = 40 feet (12.2 meters) Max. H = 8 feet (2.4 meters) Max. Ratio V to H ratio is 1:2 Table B H...
Page 18 - Top Vent - THREE ELBOWS; Ceiling
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 18 Table D H + H 1 Maximum V Minimum feet (meter) feet (meter) 5 (1.524) Elbow Only 5 (1.524) 1 (0.305) 10 (3.048) 2 (0.610) 15 (4.572) 3 (0.914) 20 (6.096) 4 (1.219) H + H 1 = 20 feet (6.096 m) Max. V + V 1 + H + H 1 = 40 ft. (12.192 m) Max. Exam...
Page 19 - to Figure 20 on; See; appliance collar. Attach in the same manner
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. HORIZONTAL (OUTSIDE WALL) TERMINATION SYSTEM See Figure 32, and Figures 35 to 40 (Pages 21 to 23) and their associated Horizontal Vent Table which illustrates the horizontal venting configu- rations that are allowed to be used with these applia...
Page 20 - Termination Guard
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 20 J. Assemble vent run to exterior wall - If not previously measured, locate the center of the vent at the exterior wall. Prepare an opening as described in Step B . Assemble the vent system to point where the terminus of the last section is loca...
Page 21 - Under no circumstances, may separate sections of; Square termination; Termination Kit Only; Table 9; HORIZONTAL VENT FIGURES/TABLES
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 21 Square termination (SV4.5HT-2) shown. WARNING Under no circumstances, may separate sections of concentric flexible vent pipe be joined together. See Table 9 as an aid in venting component selection for a particular range of exterior wall thickn...
Page 23 - Figure 4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 23 V H2 H1 H V H H1 V1 v Wall Firestop / Spacer (SV4.5HF) u Ceiling Firestop / Spacer (SV4.5VF) u Ceiling Firestop / Spacer (SV4.5VF) u Wall Firestop / Spacer (SV4.5VF) v Wall Firestop / Spacer (SV4.5HF) u When using Secure Flex, use Firestop / Sp...
Page 24 - SECuRE FLEX
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 24 D. Install Firestop / Spacers at ceilings and walls - When Secure Flex penetrates a wall or ceiling, a firestop / spacer is required: use the SF4.5 VF firestop / spacer for ceilings and the SF4.5 HF firestop / spacer for walls. See the appropri...
Page 25 - Millivolt Wiring Diagram; Verify proper operation after servicing.; CAUTION; (See Figures 45 and
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 25 Figure 43 - Millivolt Wiring Diagram Field Wired Factory Wired TH TP TH TP * Optional Control Switch Thermopile SchematicRepresentationOnly • If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105 C - 18...
Page 26 - Valve Access Side; CAUTIONS; IMPORTANT NOTE; Connect the ground supply wire to the green; Note: The supplied 15 feet of 2 conductor
26 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 5. WIRING - OPTIONAL FORCED AIR BLOWER KIT FBK-100, FBK-200 and FBK-250 Kits (See Figure 46 for wiring) - An electrical receptacle is provided for the installation of the FBK-100 , FBK-200 and FBK- 250 forced air blower kits. Electrical po...
Page 27 - Step 6. CONNECTING GAS LINE; CONTROL COMPARTMENT ACCESS/LOUVER; NOTE: The top louvered panel and the bottom; Lower Control; Gas
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 27 Figure 48 Step 6. CONNECTING GAS LINE All codes require a shut-off valve mounted in the supply line. The orientation of the shut-off valve should face the front. Figure 47 illustrates two methods for connecting the gas supply. A Sediment Trap i...
Page 28 - STONE AND GLOWING EMBERS; Note: Using a soapy water solution is an effec-
28 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 8. INSTALLING LOG SET, VOLCANIC STONE AND GLOWING EMBERS Electronic Appliance Checkout To light the burner, turn ‘ON’ the OFF/ON switch (located in the control compartment). Ensure the igniter lights the pilot. The pilot flame should engul...
Page 29 - BURNER POSITIONING; Volcanic Stone; Figure 53. This procedure is accomplished; Bag of Glowing
29 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 29 Figure 53 FRONT OF FIREPLACE REAR BURNER FRONT BURNER Outer Log Notch Location FIREBOX SUBFLOOR Outer Log Notch Location Outer Log Notch Location Outer Log Notch Location Riser - Inner Log Notch Location LOG NOTCH LOCATION RELATIVE TO BURNER...
Page 30 - Note: When installing the glass door, ensure the
30 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 30 Step 10. BURNER ADJUSTMENTS Flame Appearance and sooting Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame. When the appliance is first lit, the entire flame may be blue and wi...
Page 31 - 7 (adjustment rod is located in the lower; Combustible Wall Framing; - Burner Air Shutter Adjustment; HOOD INSTALLATION; All of these appliances must have hoods; FINISHING REQUIREMENTS; See Page 5 for Cold Climate Insula-; WARNINGS; Burner Air Shutter Adjustment Procedure; Figure 58 - Burner Flame Appearance
31 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 31 Ref. Air shutter Patent: U.S. Pat. 5,553,603 1 . Locate adjustment rod and adjust air shutter to the standard setting as shown in Figure 57 (adjustment rod is located in the lower control area). Note: Rotating the adjustment rod coun- terclo...
Page 32 - APPOSITION DES MISES EN GARDE RELATIVES; LENNOX HEARTH PRODUCTS; COLOCACIóN DE ADVERTENCIAS DE; LENNOX HEARTH PRODUCTS; Figure A
32 ATTACHING SAFETY-IN-OPERATION WARNINGS It is required that the safety instruction labels furnished with the fireplace be affixed to the op- eration and control point of the fireplace. A safety instruction label must be affixed to the wall switch plate where the fireplace is turned on and off (See...
Page 33 - INSTALLATION ACCESSORIES
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 33 Item Cat. No. Model Description 1 H1968 SV4.5HT-2 Horizontal Square Termination With Firestop / spacer (H2246) & Adapter (74L61) 2 H2152 SV4.5CGV-1 Vertical Termination Cap 3 77L70 SV4.5L6 6 Inch (152 mm) Vent Section 3 77L71 SV4.5L12 12 In...
Page 34 - Open Top Shroud Kits; Closed Top Shroud Termination Kits
34 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Item Cat. No. Model Description 18 H1969 SF4.5HT-2 Horizontal Square Termination (without flex) 18 77L87 SFKIT12S Flex Square Term. (with 12 inch [305 mm] * compressed flex) 18 77L88 SFKIT18S Flex Square Term. (with 18 inch [457 mm] * compresse...
Page 35 - this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.
35 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Natural Gas to Propane Gas Conversion Kits Fireplace Type Cat. No. (model) Millivolt 85L65 FGCK-DMOMNP Electronic 85L79 FGCK-DMOENP Propane Gas to Natural Gas Conversion Kits Fireplace Type Cat. No. (model) Millivolt 85L72 FGCK-DMOMPN Electroni...
Page 36 - All Models; NOTE: Each model has two burners and 2; Note: If the igniter is damaged, a replacement kit; Electronic Appliances; Figure 63 and the instructions provided with
36 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SIT Millivolt Gas Valve Pilot for SIT Millivolt Gas Valve Figure 62 Step 6. See Figure 62 and remove the pilot hood assembly to access the hexed pilot orifice. Remove and replace the orifice with the one provided with the kit. Pressure Regulato...
Page 37 - BURNER; ALWAYS TEST PRESSURES WITH THE VALVE
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 37 Figure 65 Figure 66 BURNER POSITIONING REAR BURNER FRONT BURNER PILOT BURNER Note: The burners are not identical. Position them so that the circular burner ports run as shown. Note especially the vertical run of ports relative to the pilot burn...
Page 38 - NOTES