Page 2 - IMPORTANT: PLEASE READ THIS
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. AVERTISSEMENT Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et rem- placer toute partie du système de contrôle et toute commande qui ont été plong...
Page 3 - dependable and enjoyable service from your SUPERIOR product.; GENERAL INFORMATION; Note: Installation and repair should be per-; TABLE OF CONTENTS; INTRODUCTION; millivolt appliances; Table 4; IMPORTANT; It is imperative that the control; Table 1; Requires Field Converion; Table 2
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. CONGRATULATIONS! In selecting this SUPERIOR B-Vent Gas Appliance you have chosen the finest and most dependable fireplace to be found anywhere. Its a beautiful, prestigious alternative to a wood burning fireplace. Welcome to a Family of tens of th...
Page 4 - Glass Cleaning; Gas Controls / Control Compartment; Table 6; must be disconnected; greater; by closing their; less than; Table 7; Figure 2; WARNING; OPERATION AND CARE OF YOUR; Pages
4 Depending on your use, the burn-in period may take a few hours or a few days. KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED BY THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR. A white film may develop on the glass front during the ...
Page 5 - Figure 3; Honeywell Electronic Gas Valve; Variable Flame Height Adjustment; Honeywell Millivolt Gas Valve; Figure 5; SIT Millivolt Gas Valve; Figure 4; Flame Height; Flame Height
Clean Lower Control Compartment Keep lower control compartment clean by vacuuming or brushing it out at least twice a year (also clean the air venturi with a brush or wire). More frequent cleaning may be required due to accumulation of lint from carpeting, bedding materials, pet hair, spider webs, e...
Page 6 - Removing Glass; Superior; VENT SPILLAGE TEST
IMPORTANT Do not use abrasive cleaners on glass. Never clean the glass when it is hot. • During start-up, it is normal for condensa- tion to form on the inside of the glass (this condensation and fog will usually disappear in a few minutes). The moisture can cause lint, dust and other airborne parti...
Page 7 - Figure 7; Outside Combustion Air Controls; Figure 8; View Without Scoop; Front Glass Enclosure Panel, Removal; Figure 9; EXERCISE EXTREME CAUTION
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 7 Figure 7 Firebox Top Lintel Securing Screw Hole in Cabinet Top Scoop Securing Screws Scoop WARNING Do not operate the shutoff lever unless a complete outside COM- BUSTION air system has been installed with your appliance. Outside Combustion Air ...
Page 8 - Table 8; Glowing Embers; Bag of Glowing; INSTALL VOLCANIC STONE, GLOWING; Removing Glass Enclosure Panel; Placement of Glowing Embers & Install
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 8 Removing Glass Enclosure Panel (see Figure 11) 1. Remove top louver assembly by pulling it up and out. 2. Remove the control compartment access door (see removal instructions on Page 4 - Removing Control Compartment Door). 3. Locate the two (2) ...
Page 9 - Log Placement Instructions; LOG SET; Install the Embers, Volcanic Stone and Logs in the order
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 9 Figure 13 MODEL SSBV-50 Log Placement Instructions LOG SET Catalog Number H67 * Item Description A Log, Rear B Log, Top Left C Log, Center D Log, Top Right * Item "letters" above correspond to photos B C D A Install the Embers, Volcanic ...
Page 10 - Install the Embers, Volcanic Stone and Logs in the order shown; Place Embers and Volcanic Stone as Shown
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 10 Figure 14 LOG SET Catalog Number H68 * Item Description A Log, Rear B Log, Top Left C Log, Center D Log, Top Right * Item "letters" above correspond to photos A C D B MODEL SSBV-405 Log Placement Instructions Install the Embers, Volcani...
Page 11 - Ensure front glass panel is in place; CAUTION; Burner Air Shutter Adjustment Procedure; Burner Air Shutter Adjustment; Figure
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 11 Figure 15 - Burner Flame Appearance Models SSBV-50 & SSBV405 Series BURNER ADjUSTMENTS (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in th...
Page 12 - WIRING DIAGRAMS; errors can cause improper and dangerous appliance operation.; Figure 20 - Millivolt Wiring Diagram; Wiring Diagram
1 Electronic Appliance Checkout To light the burner, refer to the lighting instruc- tions on Pages 18 & 19 . Ensure the igniter lights the pilot. The pilot flame should engulf the flame sensor as shown in Figure 19. With proper care and maintenance, your appli- ance will provide many years of en...
Page 13 - LHP; PRODUCT REFERENCE INFORMATION; Forced Air Kit; Model; Variable Speed Wall Switch; ACCESSORY COMPONENTS; Unit-Mountable Rocker Switch
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 1 WARRANTY Your gas appliance is covered by a limited twenty year warranty. You will find a copy of the war- ranty accompanying this manual. Please read the warranty to be familiar with its coverage.Retain this manual. File it with your other docu...
Page 14 - Eyebrow Hood Kits; Polished Brass & Brushed Stainless Louvers Kits; Interior Brick Liner Kits; Standard Remote Control System
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 14 ACCESSORY COMPONENTS (CONTINUED) Interior Brick Liner Kits The brickade liner kits include tan stamped sheetmetal panels for the rear and side walls of the firebox. The panels have brick-like features in relief. These kits can be retrofitted in...
Page 15 - - Piece Door Frame Kits; Screen Panel Kit
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 15 Arch Door Kits The arch door kits are easy to install and do not require hardware to attach them to the standard door frame. The decorative arch kits can not be used in conjunction with the screen panel kit. (ref. Form # 750,021M) -Piece Door T...
Page 16 - LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE; FOR YOUR SAFETY READ BEFORE LIGHTING; Note: Knob cannot be turned from “PILOT” to “OFF”; SIT
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 16 LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INjURY OR LOSS OF LIFE. FOR YOUR SAFETY READ BEFORE LIGHTIN...
Page 17 - INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT; INSTRUCTIONS D'ALLUMAGE; moins qu’il ne soit légèrement enfoncé. Ne le forcez pas.; POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL; HONEYWELL
17 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé. Allumez immédiatement la veilleuse en déclenchant l’allume-gaz à étincelle (en poussant le b...
Page 18 - LIGHTING INSTRUCTIONS — ELECTRONIC; TO TURN OFF GAS TO APPLIANCE; Honeywell Electronic Gas Control Valve
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 18 WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INjURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly. B. BEFORE OPERATING smell all ...
Page 19 - INSTRUCTIONS D’ALLUMAGE — ELECTRONIC; INSTRUCTIONS D’ALLUMAGE; Interrupteur; Vue de face
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 19 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE A. Lorsque vous allumez l’appareil, suivez exactement ces instruc- tions....
Page 21 - TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM; Manually Reset; TROUBLESHOOTING GUIDE - ELECTRONIC IGNITION SYSTEM
1 TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position. Important: Valve system troubleshooting should only be accomplished...
Page 22 - TROUBLESHOOTING PROCEDURE - ELECTRONIC IGNITION SYSTEM
START CHECK • Turn Off Gas Supply.• Ensure Valve Switch Is In ON Position.• Disconnect Control Harness.• Turn On Optional Remote Switch (if applicable) • Check for proper volt- age at control harness (see insert A). Voltage should be 4V between remote switch or pres-sure switch and 4V common and 4V ...
Page 24 - REPLACEMENT PARTS DIAGRAMS
LHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distribu- tor for fireplace code information. LHP 1110 West Taft Avenue • Orange, CA 9865 Printed in U.S.A. © 2005 ...