Page 2 - TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION
2 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New York City Approval ..................... Page 4Cold ...
Page 3 - Table 1
3 The appliance, when installed, must be electri- cally grounded and wired in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition , or the Canadian Electrical Code, CSA C22.1 - latest edition . Provide adequate clearances ar...
Page 4 - Figure 1; Tables 2 and 3; Table; Table 4; REQUIREMENTS FOR THE COMMON-; Manifold Pressure Tap; Flame Height; Main Gas Control Knob; SIT Millivolt Gas Valve
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Inlet Gas Supply Pressure (all models) Fuel # Minimum Maximum Natural Gas 5.0" WC (1.24 kPa) 10.5" WC (2.61 kPa) Propane 11.0" WC (2.74 kPa) 13.0" WC (3.23 kPa) Table 2 Manifold Gas Supply Pressure (all models) Fuel # Low High Na...
Page 5 - Installation; Figure 2; Typical Locations; LOCATION; Do not insulate the space between the ap-
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and ...
Page 6 - VENT TERMINATION CLEARANCES; These instructions should be used as a; Vertical Vent Termination Clearances; Figure 3A; Minimum; Figure 3A - Multiple Terminations; Termination Heights For Vents; Horizontal Vent Termination Clearances; Side Elevation View; Figure 4
6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA o...
Page 7 - Figure 5; EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS
7 VENT TERMINATION CLEARANCES Figure 5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS Canadian Installation* US Installation** A = Clearance above grade, veranda, porch,deck, or balcony. 12 inches (30cm)* 12 inches (30cm)** B = Clearance t...
Page 8 - MINIMUM CLEARANCES TO COMBUSTIBLES; inclined vent component.; Table 5; When the; Figure 8
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 5 (127) 8-1/4 (209) 14 (356) 12 (305) 19 (483) 4 (102) 2 (51) 4 (102) 6 (152) 8 (203) 10 (254) 12 (305) 6 (152) 10 (254) 14 (356) 12 (305) 8 (203) MINIMUM CLEARANCES TO COMBUSTIBLES u Note: 3 in. (75 mm) above any horizontal / inclined vent comp...
Page 9 - See; Figure 9
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. TYPICAL INSTALLATION SEQUENCE The typical sequence of installation is outlined below. However, each installation is unique and may result in variations to the steps described. See the page numbers references in the follow- ing steps for detailed...
Page 10 - FLUE
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 10 PRODUCT REFERENCE INFORMATION Cat. No. Model Ship Wt. Ship. Volume H4633 SDVST 282 lbs 52W x 27D x 44- 1/2H (36.2 cu.ft). Figure 11 NOTES • Annual Fuel Utilization Efficiency Diagrams, illustrations and photographs are not to scale – consult in...
Page 11 - Model
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 11 NOTES • Annual Fuel Utilization Efficiency Diagrams, illustrations and photographs are not to scale – consult installation instruc- tions. Product designs, materials, dimen- sions, specifications, colors and prices are subject to change or disc...
Page 12 - Table 6
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Also see Figures 11 and 12 on Pages 10 and 11 5-5/8" (143 mm) 3-1/8" (79 mm) Figure 13 - ROUTE GAS LINE Proper Sizing of Gas Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is t...
Page 13 - The VENT SEAL CAP must remain securely installed; Note: The restrictor is included within the firebox.; Step 3. INSTALL THE VENT SYSTEM; Approved Vent; on; Figure 14 and
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 13 Securing Screws (OUTSIDE OF APPLIANCE) Insulation Top Vent Vent Seal Cap Firebox Top Cabinet Top CROSS SECTION SIDE VENT SEAL CAP REMOVAL (SIDE VENT INSTALLATIONS ONLY) Insulation Vent Seal Cap Securing Screws Side Vent Cabinet Back CROSS SECTI...
Page 14 - VENT SECTION LENGTH CHART; Effective Vent Length; Table 7; Figure 22 on Page; Secure VentTM pipe applications are shown in; Figure 3B on
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 14 Figure 17 T R A H C H T G N E L N O I T C E S T N E V n o it c e S l a n i m o N ) s e h c n i ( h t g n e L 6 2 1 4 2 6 3 8 4 T O T A L Q T Y n o it c e S t e N ) s e h c n i ( h t g n e L 2 / 1 - 4 2 / 1 - 0 1 2 / 1 - 2 2 2 / 1 - 4 3 2 / 1 - ...
Page 17 - Page 6, Figures 3A and
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 17 Framing Dimensions for Roof Inches (millimeters) Pitch C D 0/12 10-1/2 in. (267 mm) 10-1/2 in. (267 mm) 6/12 10-1/2 in. (267 mm) 12 in. (305 mm) 12/12 10-1/2 in. (267 mm) 17 3/4 in. (451 mm) Figure 25 - Roof Framing C D Storm Collar Figure 27 F...
Page 18 - Ratio V to H ratio is 1:2; VERTICAL VENT FIGURES/TABLES; rate sections of concentric flexible
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 18 H V V1 V H Figure 29 - Side Vent - ONE 90 DEGREE ELBOW Figure 30 - Top Vent - TWO 90 DEGREE ELBOWS u Ceiling Firestop / Spacer (SV4.5VF) v Wall Firestop/ Spacer (SV4.5HF) u Ceiling Firestop / Spacer (SV4.5VF) u When using Secure Flex, use Fires...
Page 19 - Ceiling; ) horizontal run up to a; Top Vent - THREE ELBOWS
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 19 H1 V V1 H V H1 H V1 u Ceiling Firestop / Spacer (SV4.5VF) v Wall Firestop/ Spacer (SV4.5HF) Table C H +H 1 Maximum H Maximum V Minimum feet (meter) feet (meter) feet (meter) 5 (1.524) 2 (0.610) 1 (0.305) 10 (3.048) 4 (1.219) 2 (0.610) 15 (4.572...
Page 20 - refer to Figure
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 20 HORIZONTAL (OUTSIDE WALL) TERMINATION SYSTEM See Figure 33 , and Figures 36 to 41 (Pages 22 to 24) and their associated Horizontal Vent Table which illustrates the horizontal venting configurations that are allowed to be used with these applian...
Page 21 - Termination Guard
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 21 It is important to maintain the required clear- ances to combustibles: 1" (25 mm) at all sides for all vertical runs; and 3" (76 mm) at the top, 1" (25 mm) at sides, and 1" (25 mm) at the bottom for all horizontal / inclined run...
Page 22 - Under no circumstances, may separate sections of; HORIZONTAL VENT FIGURES/TABLES; Square termination; Termination Kit and 6 In. Vent; Table 8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 22 WARNING Under no circumstances, may separate sections of concentric flexible vent pipe be joined together. See Table 8 as an aid in venting component selection for a particular range of exterior wall thicknesses. H = 28 in. (711 mm) Maximum 7 i...
Page 25 - Figure; SECuRE FLEX
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 25 D. Install Firestop / Spacers at ceilings and walls - When Secure Flex penetrates a wall or ceiling, a firestop / spacer is required: use the SF4.5 VF firestop / spacer for ceilings and the SF4.5 HF firestop / spacer for walls. See the appropri...
Page 26 - Step 4. FIELD WIRING; Blower Wiring Diagram; If any of the original wire as supplied must be replaced,; Wiring Diagram; Factory Wired; Verify proper operation after servicing.; CAUTION; Valve Access Side
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 26 Step 4. FIELD WIRING Note: The gas valve is set in place and pre-wired at the factory. A. SIT and Honeywell Millivolt Wiring (See Figure 44) 1. Select any of the following optional controls: wall-mounted switch, wall thermostat or remote contro...
Page 27 - Connect the black supply wire to the top; CAUTIONS; Connect the ground supply wire to the outlet
27 Step 5. WIRING - OPTIONAL FORCED AIR BLOWER (FBK-100) (See Figure 45) - An optional ON/Off (FRS) control switch is also available (installs on bracket below valve). An electrical outlet box is factory installed for the connection of the electrical power supply to the blower. 1. Route a 3-wire, 12...
Page 28 - Step 6. CONNECTING GAS LINE; Figures; Gas; CONTROL COMPARTMENT ACCESS/LOUVER; Lower Control
28 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 6. CONNECTING GAS LINE All codes require a shut-off valve mounted in the supply line. The orientation of the shut-off valve should face the front. Figure 47 illustrates two methods for connecting the gas supply. A Sediment Trap is recommen...
Page 29 - A. Light the appliance (refer to the lighting; TION; Millivolt Appliance Checkout; TEST ALL CONNECTIONS FOR GAS LEAKS; STONE AND GLOWING EMBERS
29 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Turn on gas supply and test for gas leaks using a gas leak test solution (also referred to as bubble leak solution). Note: Using a soapy water solution is an effec- tive leak test solution but it is not recommended, because the soap residue tha...
Page 30 - Note: If the burners have been removed for; Bag of Glowing; REFERENCE; Volcanic Stone
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 30 Figure 52 BURNER POSITIONING REAR BURNER FRONT BURNER PILOT BURNER Note: The burners are not identical. Position them so that the circular burner ports run as shown. Note especially the vertical run of ports relative to the pilot burner. Bracke...
Page 31 - Page 28, Reinstalling Control; Note: When installing the glass door, ensure the
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 31 Step 9. INSTALLATION AND REMOVAL OF GLASS DOOR Removing Glass Enclosure Panels (see Figure 55 ) 1. Remove the top louver assembly by lifting it up and pulling it out. 2. Remove the control compartment access door (see removal instructions on Pa...
Page 32 - Figure 57 - Burner Flame Appearance; Locate adjustment rod and adjust air shutter; Light appliance (follow lighting procedure; Combustible Wall Framing; Step 11. HOOD INSTALLATION; All of these appliances must have hoods; FINISHING REQUIREMENTS; See Page 5 for Cold Climate Insula-; WARNINGS; Burner Air Shutter Adjustment Procedure; - Burner Air Shutter Adjustment
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 32 Figure 57 - Burner Flame Appearance 1. Locate adjustment rod and adjust air shutter to the standard setting as shown in Figure 56 (adjustment rod is located in the lower control area). Note: Rotating the adjustment rod coun- terclockwise decrea...
Page 33 - Figure A
33 Step 12. ATTACHING SAFETY-IN-OPERATION WARNINGSIt is the installer ' s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. APPOSITION DES MISES EN GARDE RELATIVES à L...
Page 34 - INSTALLATION ACCESSORIES
34 Item Cat. No. Model Description 1 H1968 SV4.5HT-2 Horizontal Square Termination With Firestop / spacer (H2246) & Adapter (74L61) 2 H2152 SV4.5CGV-1 Vertical Termination Cap 3 77L70 SV4.5L6 6 Inch (152 mm) Vent Section 3 77L71 SV4.5L12 12 Inch (305 mm) Vent Section 3 77L72 SV4.5L24 24 Inch (61...
Page 35 - Item; Horizontal Square Termination (without flex); All compressed flex vents can be expanded up to two times.
35 22 23 19 Se ala nt 20 Item Cat. No. Model Description 18 H1969 SF4.5HT-2 Horizontal Square Termination (without flex) 18 77L87 SFKIT12S Flex Square Term. (with 12 inch [305 mm] * compressed flex) 18 77L88 SFKIT18S Flex Square Term. (with 18 inch [457 mm] * compressed flex) 18 77L89 SFKIT24S Flex ...
Page 37 - this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.; Removing Glass Enclo-
37 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Natural Gas to Propane Gas Conversion Kits Fireplace Type Cat. No. (model) Millivolt 85L65 FGCK-DMOMNP Propane Gas to Natural Gas Conversion Kits Fireplace Type Cat. No. (model) Millivolt 85L72 FGCK-DMOMPN FRONT OF FIREPLACE REAR BURNER FRONT B...
Page 38 - Test All Connections For Gas Leaks; VERIFY THE PROPER ORIFICE SIZES; Table 9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 38 SIT Millivolt Gas Valve Pilot for SIT Millivolt Gas Valve Figure 61 Pressure Regulator Remove These Components Figure 60 PilotOrifice NOTE: Flame appearance will diminish 4% per thousand feet. NOTE: Each model has two burners and 2 Orifices. Bu...