Page 5 - • Mobile home installations must conform with the Mobile Home Con-; WARNING; THIS FIREPLACE HAS BEEN ALTERED TO
5 Fireplace Requirements These heaters are designed to be installed into an existing masonry fireplace (built to UBC 37 or ULC S628 standards) or factory built solid fuel, wood burning fireplace (listed to UL 127 or ULC S610) only. All exhaust gases must be vented outside the structure. Combustion a...
Page 6 - COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
6 Installation of these appliances are approved for installation in New York City in the US state of New York (MEA#: 138-07-E). (Massachusetts Approval #G3-0806-6) These appliances are approved for installation in the US state of Mas- sachusetts if the following additional requirements are met: • In...
Page 7 - SDVI; NATURAL GAS
7 Features Installation Options Residential - Vented Vertical Only Manufactured (Mobile) Home Natural Gas Or Propane (LP) Bedrooms Optional Wall-mounted Or Remote Thermostat Electrical The blower motor requires 120 Volts AC for operation. The fireplace is not dependent on the blower or an outside el...
Page 8 - tap tights when removed.; Minimum Fireplace Cavity; Top View; Insert Dimensions; Width of insert behind Surround Panels; Figure 1; Air Intake; CAUTIONS; RTV high temperature silicone is an approved
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Insert Dimensions Minimum Fireplace Opening Required A = 31-1/4” (794mm) Front OpeningB = 17-1/4” (438mm) HeightC = 19” (483mm) Rear Width**D = 16” (406mm) Fireplace Depth * Top air duct will need to be removed for short ZC applications. Replace...
Page 9 - INSERT LEVELING; CL; Mantel; MINIMUM CLEARANCES TO COMBUSTIBLES; The letters below, E through J, correspond to; HEARTH PROTECTION; G = Minimum Hearth Protection from Front of Insert*; Clearances; Figure 4
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Facing and Mantel Side View Facing and Mantel Clearances Note: Hearth protection to be min. 3/8” (10mm) thick non-combustible or equivalent, with a k factor of .84. INSERT LEVELING At each front and rear corner of the insert is an adjustable leg...
Page 10 - Masonry and Factory Built Fireplaces; Figure 6a - Terminating Air Inlet in Chimney; NOTE: Terminating the air intake liner as shown here may not be al-; Vertical Venting; Venting Installation; Note: Measured from flue collar on; Figure 6b; Direct-Vent Fireplace Insert Vent Requirements - Use liner; Vent Kits; FKDVI; INSTALLATION
10 Air Inlet Liner (for combustion air) When terminating the air inlet liner at this point, a positive flue connection is required (to ensure combustion air is drawn down the chimney only). Exhaust 3" (75mm) UL 1777. A full length liner is required from the exhaust outlet on appli- ance to cente...
Page 11 - Figure 7; Figure 9; Screws
11 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Zero Clearance Fireplace Installation This insert may be installed in a masonry or factory built/zero clearance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured open. T...
Page 12 - Surround Panels Installation; ) from the parts bag and; Face Installation; Spring Handle Latches
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 10 Surround Panels Installation The SDVI insert surround panels are made of heavy gage steel for durabil- ity and, if desired, for the ease of making an inside fit in the fireplace. 1. Remove the speed nuts (A in Figure 12 ) from the par...
Page 13 - Robertshaw Millivolt Gas Valve; Pressure Tap
13 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Thes...
Page 14 - See Detail Shutter Adjustment
14 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Moving shutter bracket to the right will open shutter, to the left will close shutter. Figure 14 Figure 15 SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter Adjustment Detail
Page 15 - ). To properly complete the installation of this; LENNOX HEARTH PRODUCTS; La chimenea caliente; Un foyer chaud peut causer; ADVERTENCIA; INSTALLER INSTRUCTIONS -; Hot Fireplace Will Cause; ) ou sur le thermostat; LENNOX HEARTH PRODUCTS; ) y en el transmisor; LENNOX HEARTH PRODUCTS; AVERTISSEMENT
15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. La chimenea caliente cau- sará quemaduras gravesNunca permita que los niños toquen el vidrio ni otras partes de la chimenea ADVERTENCIA Un foyer chaud peut causer de graves brûluresNe laissez jamais un enfant toucher à la vitre ou à toutes autr...
Page 16 - Page
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Operating Instructions Pre-Lighting Checklist Be sure to check these items before the initial lighting of the insert: c The insert gas label corresponds to the gas supply available - that is "natural gas" for natural gas or "LP gas&...
Page 17 - Gas Control Knob; Piezo Igniter; WARNINGS
17 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 5. Locate the pilot by looking over the top of the left front log. A blue flame will be seen when the pilot is lit. 6. Turn the gas control knob counter-clockwise to the "PILOT" position. 7. Push the knob all the way in and hold in that...
Page 18 - Flame Color and Behavior; Burner Flame Appearance; Paint Curing; Once the blower turns on, turn the knob to the desired speed. No; Optional Wall Thermostat; Do not mount the thermostat where it may be affected by:
18 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Flame Color and Behavior Your SDVI gas insert is designed for maximum heating efficiency. Therefore, upon lighting of the main burner the flames will be semi-transparent or “bluish.” After 10-20 minutes of operation the logs will heat up and th...
Page 19 - Thermostat Wire
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Operating Options The rocker switch on your SDVI gas insert is used to turn the burner on and off while the pilot is on. The rocker switch can be installed in the hole in the right side of the top surround panel or in the hole in the panel to t...
Page 20 - Turn off gas and electrical power to the fireplace
20 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. CAUTION: Wear gloves and safety glasses for protection while doing required maintenance. Verify proper operation after servicing. S'assurer que l'appareil fonctionne adéquatement une fois l'entretien terminé. Maintenance Checklist The following...
Page 24 - REPLACEMENT PARTS - MODEL SDVI
24 Touch-Up Paint Kit 70K99 TSPK-B Touch-Up Paint, Metallic Black (12 oz aerosol) P A I N T Wall Thermostat Remote Control Controls Cat. No. Model Description 70005 RT-AC Remote Thermostat AC (ref. form #775280M) H0251 RCL-STAT Remote Control, RCL-STAT, Deluxe Thermostat DC (ref. form #750129M) H463...
Page 25 - NOTE: The form numbers referenced are the part numbers of the
25 Arched Face NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 4 Gear clamps Termination Cap Flashing Vent Kits H0909 FKDVI Flex Liner Kit, DVI 3” X 35’ (requires 2, one for exhaust and one for intake) TKDVI TKDVI Termination Kit, DVI (termination cap and flashing) DV3FK35 DV3FK35 Flex Liner an...
Page 26 - HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP; MINIMUM CLEARANCES; DATE OF MANUFACTURE / DATE DE FABRICATION; SAFETY / LISTING LABEL
26 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. MINIMUM CLEARANCES TO COMBUSTIBLES E = 31.5” (800mm) from Top Facing to Bottom of Insert F = 25.5” (648mm) from Center of Glass to Side Facing or Side Wall *J = 39” (991mm) from 10.5” (267mm) Mantel to Bottom of Insert * See owner’s manual for ...
Page 27 - LIGHTING LABEL
27 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. CAUTION: YOUR SUPERIOR™ GAS APPLIANCE MUST ALWAYS BE OPERATED WITH GLASS DOOR IN PLACE. STOP! Read the safety information above before proceeding. 1. Open the lower door. Make sure gas supply shut-off cocks are open and ON/OFF Rocker Switch is ...
Page 28 - Natural Gas; WARRANTY; LHP
Printed in U.S.A. © 2008 LHP P/N 506056-01 REV. C 03/2010 LHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Your Applianc...