Page 2 - TABLE OF CONTENTS; Tools should Include:
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2Tools and Building Supplies ............ page 2 Precautions ..................................... page 3 Introduction ..................................... page 3 Clearances/H...
Page 3 - Figure 1; TYPICAL INSTALLATION; PRECAUTIONS; Radiant Model Shown
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • dry wall • etc. • plywood PRECAUTIONS Note: These fireplace systems are not difficultto install. However, in the interest of safety, ...
Page 4 - Figure 5 and confine the final location of; Chase Enclosure; Figure 2 for a typical chase configura-
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 Figure 2 Chimney Height The total height of your completed fireplacesystem from the surface the fireplace rests onto the chimney top must not exceed 60' andmust also meet minimum height requirements.Refer to the minimum system height chart. LOCATION...
Page 5 - Note: The “Z” type safety strip is not supplied.; CLEARANCES; Install optional outside combustion air kit.; Study the three dimensional illustration (; PRE-INSTALLATION NOTES; Figure 7
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 Note: Install the hearth extension only as illus-trated. The safety strips should extend from front ofthe fireplace at least 1-1/2" and should extend tobe at least flush with the sides. In the event awooden support is used to elevate the firepla...
Page 6 - FIREPLACE SPECIFICATIONS; Consult all local codes.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 FIREPLACE SPECIFICATIONS Figure 10 Blocking Metal Safety Strips Figure 8 Figure 9 Step 3. Refer to fireplace drawings and specifi-cations on pages 6 and 7 for framing dimensionsand details. Frame appliance enclosure as illus-trated in Figures 11 thr...
Page 7 - FRAMING SPECIFICATIONS
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 FRAMING SPECIFICATIONS Figure 11 Figure 12 Figure 13 Figure 14 Framing Dimensions A 42-1/4" 1073 mm B 1 37-1/2" 953 mm B 2 54-1/2" 1384 mm C 28-3/4" 730 mm D 15-3/8" 391 mm E 70" 1778 mm F 35" 889 mm G 20-5/8" 524 mm ...
Page 8 - INSTALLING THE CHIMNEY SYSTEM; refer
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Step 4. Fireplace should be fastened to sideframing members using the nailing tabs at thetop and bottom of the fireplace front face. Use8d nails or equivalent ( Figure 17 ). Step 3. Position appropriate firestop spacer atceiling and nail temporarily...
Page 9 - when passing through the floor or ceiling; For Canada Only; installation is required only for use in Canada.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 F8FS30-2 Firestop Spacer FTF8-S4 Stabilizer 2" Min. Air Space 30 ° Firestop And Attic Above 10' Max. Attic Space 2" Min. Air Space F8FS30-2 Firestop Spacer FTF8-S4 Stabilizer 30 ° Firestop And Room Above 10' Max. Room Above 2" Min. Air S...
Page 10 - Roof Pitch
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Next, slide roof flashing over extended chimneysection that previously has been installed abovethe roof opening in Step 4. FTF8 flashingsrequire flashing spacers. Slide flashing all theway down until the flashing base rests flat onthe roof ( Figure...
Page 11 - The effective heights of the components are:; The Fireplace; SPECIAL OFFSET INSTRUCTIONS; offset and return elbows. Use; MULTIPLE TERMINATIONS
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 Figure 34 Figure 35 This suggestion is provided in the interest ofbetter operation. If the terminations are locatedtoo close to each other, smoke may migratefrom one flue into the other. FTF8 CHIMNEY COMPONENTCALCULATIONS The minimum installed heig...
Page 12 - OFFSET CALCULATIONS; FTF8 VERTICAL ELEVATION CHART
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 The offset and return elbows may be attachedtogether, or a section or sections of chimneymay be used between, but do not exceed 20' intotal length between elbows. If sections of pipeexceed 10' between elbows, a chimney stabi-lizer must be used at t...
Page 13 - OFFSET ELEVATION CHART
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 A B FTF8-ES30 Number of FTF8 Chimney Sections Offset Height Offset/Return FTF8-S4 (Inches) (Inches) Elbow Stabilizer 12" 18" 38" 48" 4 15 ³⁄₄ 1 0 0 0 0 0 9 24 ¹⁄₂ 1 0 1 0 0 0 12 29 ³⁄₄ 1 0 0 1 0 0 14 ¹⁄₄ 33 ¹⁄₂ 1 0 2 0 0 0 17 ¹⁄₄ 38...
Page 14 - FIGURES; INSTALLING OFFSETS
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Step 1. Determine the offset distance wherechimney is to pass through the first ceiling-dimension “A.” To find this point on your ceil-ing, first determine the center point for a verti-cal chimney following the instructions for ver-tical installati...
Page 15 - Combustion; Vent Free Appliances
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 Figure 42 Figure 43 HOUSEWIRING COVER PLATEReplace Cover PlateAfter ElectricalHook-Up POWER TO THE FIREPLACEThe Optional Blower KitOperates on 115 volt 60 Hz150 watts AC GROUNDWIRE House Wiring Must Be SecuredWith The Appropriate ElectricalConnecto...
Page 17 - Table 1; Methods of Determini
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Figure 47 A B D C C Hearth Extension Dimensions A 16" B 35" C 8" D 51" Note: To convert inches to millimetersdivide by 0.03937 Answer - The minimum required thickness of the Micore 160 is .417”,therefore round up to nearest standard...
Page 18 - FINISH TO YOUR TASTE; brick; x T; mortar; marble; x T; mortar; x T
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 Secure the hearth extension to the floor toprevent possible shifting. FINISH TO YOUR TASTE There are a wide variety of “finished looks” forthese fireplaces, from formal wall decor withelaborate mantels to rustic wood paneling orwarm brick facings. ...
Page 19 - Shipping Weight; INSTALLATION COMPONENTS
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 Storm Collar 63L59 FSC 63L38 F8F6 Flashing 63L39 F8F12 Round Termination 63L42 FTF8-CTD Forced Air Blower Kits-Single Speed 80L84 FBK-100 -Variable Speed 80L85 FBK-200 (FBK-200 Models Only) Outside Combustion Air Kits(with duct) FOAK (without duct)...
Page 20 - LHP
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 Printed in U.S.A. © 2007 by LENNOX HEARTH PRODUCTS P/N 700,040M REV. A 02/2008 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and ...