Page 3 - Contents; Preface
iii Contents Preface xi 1. Product Overview 1 Single and Dual Port HBA Features 2 Minimum System Hardware Requirements 3 Supported Operating Systems 4 2. Supported System Configurations 5 Basic Interoperability 6 Host Platform Support 6 Storage System Support 7 Fibre Channel Switch Support 7 Solaris...
Page 4 - Hardware Installation
iv Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In- 3. Hardware Installation 13 ▼ To Verify the Packaging Contents 14 ▼ To Install the HBA Hardware 14 ▼ To Attach the Optical Cable 16 ▼ To Apply Power 18 ▼ To Verify Proper Installation i...
Page 5 - To Create a Windows Boot Disk; Declaration of Conformity
Contents v ▼ To Create a Windows Boot Disk 33 Service Contact Information 33 A. Declaration of Conformity, Regulatory Compliance, and Safety Statements 35 Declaration of Conformity 37 Regulatory Compliance Statements 39 Safety Agency Compliance Statement 43
Page 7 - Figures
vii Figures FIGURE 3-1 Removing the Bracket Screws 15 FIGURE 3-2 Installing the Single and Dual Port HBAs 16 FIGURE 3-3 Attaching the Optical Cable 17
Page 9 - Tables
ix Tables TABLE 1-1 Single and Dual Port HBA Features 2 TABLE 2-1 Sun Solaris 8, 9, and 10; Red Hat Enterprise Linux and SuSE Enterprise Linux; and Windows2000 and Windows Server 2003 Host Platform Support 6 TABLE 3-1 Optical Cable Specifications 17 TABLE 3-2 LED Indicator Status Definitions 18 TABL...
Page 11 - How This Document Is Organized; Chapter 1
xi Preface This manual describes how to install, configure, and test the Sun StorageTek™Enterprise PCI-X 4 Gb Fibre Channel (FC) Single or Dual Port Emulex Host BusAdapter (HBA). This document is written for technicians, system administrators,authorized service providers (ASPs), and users who have a...
Page 12 - Using UNIX Commands; This document does not contain information about basic UNIX; Shell Prompts
xii Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Using UNIX Commands This document does not contain information about basic UNIX ® commands and procedures such as shutting down the system, booting the system, and configurin...
Page 13 - Typographic Conventions; The following documents are available at:; su
Preface xiii Typographic Conventions Related Documentation The following documents are available at: http://www.sun.com/products-n- solutions/hardware/docs/Network_Storage_Solutions/SAN/san_software/ index.html and http://docs.sun.com/app/docs/doc/819-0139. Typeface * * The settings on your browser ...
Page 14 - Third-Party Web Sites
xiv Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Documentation, Support, and Training Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in thisdocument. Sun does not endors...
Page 15 - Product Overview; single and dual port
1 C H A P T E R 1 Product Overview This chapter provides a basic overview of the Sun StorageTek Enterprise PCI-X 4 GbFC Single and Dual Port Emulex HBAs (henceforth referred to as single and dual port HBAs ). It contains the following topics: ■ “Single and Dual Port HBA Features” on page 2 ■ “Minimu...
Page 16 - See
2 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Single and Dual Port HBA Features The single and dual port HBAs consist of a single-slot PCI-X 2.0 bus expansionboard that interfaces a 64-bit PCI bus to one or two Fibre Chann...
Page 18 - Supported Operating Systems; Requirements” on page 8
4 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Supported Operating Systems You can use the single and dual port HBAs with the following operating systems: ■ Solaris 8, 9, and 10 Operating Systems To use the single and dual ...
Page 19 - Supported System Configurations
5 C H A P T E R 2 Supported System Configurations This chapter describes the operating systems, host platforms, storage, andinfrastructure configurations that support the Sun StorageTek Enterprise PCI-X 4 GbFC Single and Dual Port Emulex HBAs (henceforth referred to as single and dual port HBAs ). I...
Page 20 - Basic Interoperability; “Host Platform Support” on page 6; Host Platform Support
6 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Basic Interoperability This section provides information about platform, storage, and switch compatibilitypermitting a heterogeneous Fibre Channel network design with the singl...
Page 21 - Storage System Support
Chapter 2 Suppor ted System Configurations 7 Storage System Support The single and dual port HBAs support the storage systems are listed below. ■ Sun StorEdge™ 3510 and 3511 FC arrays ■ Sun StorEdge 6020, 6120, and 6320 arrays ■ Sun StorEdge 6130 array ■ Sun StorEdge 6920 system ■ Sun StorEdge L25 a...
Page 22 - Minimum Operating System Levels; Solaris 8 SPARC; Note –; version required for your HBA installation.
8 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Solaris 8, 9, and 10 Operating SystemRequirements This section contains information about using the single and dual port HBAs withthe Solaris OS. Minimum Operating System Level...
Page 23 - Minimum OS Levels
Chapter 2 Suppor ted System Configurations 9 Red Hat Enterprise Linux and SuSELinux Enterprise Server OperatingSystem Requirements This section contains information about using the single and dual port HBAs in RedHat Enterprise Linux and SuSE Linux Enterprise operating systems. Minimum OS Levels ■ R...
Page 24 - Known Issues and Bugs
10 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Windows 2000 and Windows Server 2003Operating System Requirements This section contains information about using the single and dual port HBAs inWindows 2000 and Windows Server...
Page 27 - single and dual; Caution –; Damage to the HBA can occur as the result of careless handling or
13 C H A P T E R 3 Hardware Installation This chapter provides instructions for installing the Sun StorageTek Enterprise PCI-X4 Gb FC Single and Dual Port Emulex HBAs (henceforth referred to as single and dual port HBAs ) in your system. It contains the following topics: ■ “To Verify the Packaging C...
Page 28 - To Verify the Packaging Contents; Alternate PCI bracket; To Install the HBA Hardware; IEEE; bracket by performing the following steps:
14 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 ▼ To Verify the Packaging Contents ● Confirm that the single or dual port HBAs are shipped with the followingitems: ■ Sun StorageTek Enterprise PCI-X 4Gb FC Single or Dual Por...
Page 29 - b. Remove the bracket and store it for future use.; d. Replace the screws that attach the HBA to the bracket.
Chapter 3 Hardware Installation 15 FIGURE 3-1 Removing the Bracket Screws b. Remove the bracket and store it for future use. c. Align the new mounting bracket tabs with the holes in the HBA. Note – Be careful not to push the bracket past the transceiver housing’s grounding tabs. Ensure that the LEDs...
Page 30 - To Attach the Optical Cable; HBA
16 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 FIGURE 3-2 Installing the Single and Dual Port HBAs Note – FIGURE 3-2 is a typical installation, which may differ from your installation. ▼ To Attach the Optical Cable Note – ...
Page 31 - Follow these steps when attaching the optical cable:; Connect the other end of the cable to the Fibre Channel device.
Chapter 3 Hardware Installation 17 Follow these steps when attaching the optical cable: 1. Connect the fiber-optic cable to an LC connector on the dual port HBA ( see FIGURE 3-3 ). FIGURE 3-3 Attaching the Optical Cable 2. Connect the other end of the cable to the Fibre Channel device. After the opt...
Page 32 - To Apply Power; Verify that the HBA is securely installed in the system.; summarizes LED indicator combinations. The LEDs can be seen
18 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 ▼ To Apply Power 1. Verify that the HBA is securely installed in the system. 2. Verify that the correct optical cable is attached. 3. Plug in and power on the system. 4. Obser...
Page 33 - command at the; ok; prompt to list the installed devices.
Chapter 3 Hardware Installation 19 ▼ To Verify Proper Installation in SPARCPlatforms 1. Enter the show-devs command at the ok prompt to list the installed devices. The single and dual port HBAs can be identified in the output containing the SUNW,emlxs@n and SUNW,emlxs@n,1 node names, where n is usua...
Page 35 - To Verify the Attached Storage; command to list the attached storage.; You may need to use the
Chapter 3 Hardware Installation 21 ▼ To Verify the Attached Storage ● If online storage is connected to the HBA installed in a SPARC system, use the apply show-children command to list the attached storage. In the example that follows, a storage JBOD has twelve targets attached to one portof the dua...
Page 36 - Service Contact Information
22 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 ▼ To Verify Proper Installation in x64 BasedSystems ● Follow the instructions in the BIOS documentation provided with yoursystem. Service Contact Information If you need help ...
Page 37 - Software Installation; This chapter contains the following topics:
23 C H A P T E R 4 Software Installation After you have completed the hardware installation and powered on the computer,follow the instructions listed for your operating system to install the single and dualport HBA driver and any other utilities required for your installation. The followingsections...
Page 38 - To Download Solaris Patch Clusters; Click on Patch Portal under Recommended and Security Patches.
24 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Installing the HBA Driver With SolarisOperating Systems You must first install the latest available patch clusters for your Solaris OS. This section contains the following top...
Page 39 - “To Run An; To Run An; If you are not already logged in, the Login page displays.; Enter your User Name and Password and click Login.; The Download page is now available.; Locate and click the download file; The necessary packages and patches install.; Reboot the system after installing all patches.; This completes the driver installation.
Chapter 4 Software Installation 25 The packages and patches are available either bundled as a script posted in the SunDownload Center (SDLC), or as individual packages and patches. Sun recommendsusing the install_it script, see “To Run An install_it Script Installation” on page 25 . To install the p...
Page 40 - To Do A Manual Installation; Packages; SUNWemlxs; Patches
26 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 ▼ To Do A Manual Installation Optionally, for Solaris 8 and 9, if you do not want to use the install_it script, install the driver by adding the following packages and then pa...
Page 41 - The SunSolve Online license agreement page displays.; Download the appropriate patches for your system from
Chapter 4 Software Installation 27 1. Go to http://sunsolve.sun.com . The SunSolve Online license agreement page displays. 2. Accept the License Agreement. The SunSolve Online page displays. 3. Under Patches and Updates, click PatchFinder. 4. Download the appropriate patches for your system from TAB...
Page 42 - To Download the Packages; Type your User Name and Password and click Login.
28 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Downloading HBA Driver Packages and Patchesfor Solaris 10 for SPARC or x64/x86 There is no install_it script available to install the drivers for Solaris 10. If you areusing t...
Page 43 - To Download the Patches; Perform the following steps to download the Solaris 10 patches.; dash number) in the Enter Patch ID box and click Find Patch.; Diagnostic Support
Chapter 4 Software Installation 29 ▼ To Download the Patches Perform the following steps to download the Solaris 10 patches. 1. Go to http://sunsolve.sun.com . The SunSolve Online license agreement page displays. 2. Accept the License Agreement. The SunSolve Online page displays. 3. Under Patches an...
Page 44 - To Download and Install the Packages; download link for the Driver kit.; “Creating a Linux Boot Disk” on page 31
30 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Installing the HBA Driver With Red Hatand SuSE Operating Systems The Red Hat Enterprise Linux (RHEL) 3 and 4 and the SuSE Linux Enterprise Server(SLES) 8 and 9 operating syste...
Page 45 - Red Hat and SuSE OS Diagnostic Support; lputil; Creating a Linux Boot Disk
Chapter 4 Software Installation 31 Red Hat and SuSE OS Diagnostic Support Diagnostic support is provided by the Emulex lputil and HBAnyware utilities. They support the following functions: ■ List adapters ■ Adapter information ■ Firmware maintenance ■ Reset adapters To verify the installation, follo...
Page 46 - file at the; To Install the HBA Driver; Miniport Driver or SCSIport Miniport driver.; To create a Windows boot disk, see
32 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007 Installing the HBA Driver WithWindows 2000 or Windows Server 2003Operating Systems The Windows 2000 and Windows Server 2003 operating systems are supported onthe single and du...
Page 49 - “Declaration of Conformity” on page 37
35 A P P E N D I X A Declaration of Conformity,Regulatory Compliance, and SafetyStatements This appendix contains the following information that applies to the Sun StorageTekEnterprise 4 Gb Fibre Channel Single and Dual Port Host Bus Adapter: ■ “Declaration of Conformity” on page 37 ■ “Regulatory Co...
Page 51 - EMC; European Union
37 Declaration of Conformity EMC USA—FCC Class A This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:1. This equipment may not cause harmful interference.2. This equipment must accept any interference that may cause undesired operation. Europea...
Page 53 - Regulatory Compliance Statements; FCC Class A Notice
39 Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class: • Federal Communications Commission (FCC) — USA • Industry Canada Equipment Standard for Digital Equipment (ICES-003) — Canada • Voluntary Control Council for Interference (VCCI) — Japan • Bureau of Stan...
Page 55 - BSMI Class A Notice
Regulatory Compliance Statements 41 BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliancelabel. GOST-R Certification Mark D33012
Page 57 - Safety Precautions; Symbols
43 Safety Agency ComplianceStatement Read this section before beginning any procedure. Thefollowing text provides safety precautions to follow wheninstalling a Sun Microsystems product. Safety Precautions For your protection, observe the following safetyprecautions when setting up your equipment: ■ ...
Page 59 - Rack System Warning; Laser Compliance Notice; Conformité aux normes de sécurité; Mesures de sécurité
Safety Agency Compliance Statement 45 Rack System Warning The following warnings apply to Racks and Rack Mountedsystems. Caution – For safety, equipment should always be loaded from the bottom up. That is,install the equipment that will be mounted inthe lowest part of the rack first, then the nexthi...
Page 61 - Mise en garde relative aux batteries; Mise en garde relative au système en rack
Safety Agency Compliance Statement 47 Attention – Tous les cordons d'alimentation ne présentent pas les mêmes caractéristiquesélectriques. Les cordons d'alimentation àusage domestique ne sont pas protégés contreles surtensions et ne sont pas conçus pour êtreutilisés avec des ordinateurs. N'utilisez ...
Page 62 - Avis de conformité des appareils laser; Einhaltung sicherheitsbehördlicher; Sicherheitsvorkehrungen
48 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Por t Emulex HBA Installation & Interop Guide • January 2007 Attention – Afin d'éviter que le rack ne penche pendant l'installation du matériel, tirezla barre anti-basculement du rack. Attention – Pour éviter des températures de foncti...
Page 63 - Modifikationen des Geräts
Safety Agency Compliance Statement 49 Je nach Netzschaltertyp an Ihrem Gerät kann eines derfolgenden Symbole verwendet werden: Ein – Versorgt das System mit Wechselstrom. Aus– Unterbricht die Wechselstromzufuhr zum Gerät. Wartezustand – Der Ein-/Standby-Netz- schalter befindet sich in der Standby-Po...
Page 65 - Hinweis zur Laser-Konformität; Normativas de seguridad; Medidas de seguridad
Safety Agency Compliance Statement 51 Hinweis zur Laser-Konformität Sun-Produkte, die die Laser-Technologie verwenden,entsprechen den Laser-Anforderungen der Klasse 1. CD- und DVD-Geräte Die folgende Warnung gilt für CD-, DVD- und andereoptische Geräte: Achtung – Die hier nicht aufgeführte Verwendun...
Page 66 - Conexión del cable de alimentación; Advertencia sobre las baterías
52 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Por t Emulex HBA Installation & Interop Guide • January 2007 Nivel de ruido Declared noise emissions in accordance with ISO 9296,A-weighted, operating and idling: Cumplimiento de la normativa para instalaciones SELV Las condiciones de ...
Page 67 - Nordic Lithium Battery Cautions
Safety Agency Compliance Statement 53 Cubierta de la unidad del sistema Debe extraer la cubierta de la unidad del sistemainformático Sun para instalar tarjetas, memoria odispositivos de almacenamiento internos. Vuelva a colocarla cubierta antes de encender el sistema informático. Precaución – No pon...
Page 68 - Danmark; Suomi
54 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Por t Emulex HBA Installation & Interop Guide • January 2007 Danmark Advarsel! – Litiumbatteri — Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kunske med batteri af samme fabrikat og type.Levér det brugte batteri tilbage til...