Summary
Virtual Tape StorageSubsystem (VTSS) for VSM5 ® Planning and System Assurance Guide
96257 Sun Confidential: Internal Only v Revision A Revision History / Summary of Changes EC Doc PN SAP Revision Release Date Supported Versions / Summary of Changes 133687 96257 A September 2006 New document created for FRS release of VSM5-VTSS system (Phase 1), including 2Gb back-end FC loops, VCF3...
vi Sun Confidential: Internal Only 96257 Revision A Contents Revision History / Summary of Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
96254 Sun Confidential: Internal Only ix Revision A Figures Figure 1-1. System Assurance Process Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23Figure 2-1. VSM Quick Tool – Tool Selection Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
96254 Sun Confidential: Internal Only x Revision A Tables Table 2-1. Configuration Planning Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27Table 2-2. VSM5-VTSS Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
xi Sun Confidential: Internal Only 96257 Revision A Notices ■ Warranty Notice This document neither extends nor creates warranties of any nature, expressed or im-plied. Sun cannot accept any responsibility for your use of the information in this docu-ment, or for your use of any associated software ...
96257 Sun Confidential: Internal Only xii Revision A ■ Hazardous Materials Handling Lead-acid battery packs and lithium-battery cards used in the VSM-VTSS are classified as hazardous materials. Sun personnel are required to comply with U.S. Department of Transportation (DOT), International Civil Avi...
96257 Sun Confidential: Internal Only xiv Revision A ■ Internal Code License Statement NOTICE INTERNAL CODE LICENSE PLEASE READ THIS NOTICE CAREFULLY BEFORE INSTALLING AND OPERATING THIS EQUIPMENT. THIS NOTICE IS A LEGAL AGREEMENT BETWEEN YOU (EITHER AN INDIVIDUAL OR ENTITY), THE END USER, AND SUN M...
xv Sun Confidential: Internal Only 96257 Revision A Safety / Fiber Optic / ESD Precautions The following precautions must be followed during all phases of equipment installation, operation, and servicing. Equipment users are responsible for following warnings and cautions, and for taking other appro...
96257 Sun Confidential: Internal Only xvi Revision A Strictly Comply With Caution and Warning Messages To prevent injury and equipment damage, comply with all caution and warning messages in this document. Also employ any and all other precautions which you deem necessary for safe operation of equip...
xvii Sun Confidential: Internal Only 96257 Revision A ■ Fiber Optic Component Handling Precautions To prevent damage to optical fiber cables and connectors, and to mitigate inherent haz-ards from laser-light emissions, always follow these general handling precautions: Protect Your Eyes Never aim the...
About This Guide xviii Sun Confidential: Internal Only 96257 Revision A About This Guide ■ Product Overview The Sun StorageTek Virtual Storage Manager® (VSM®) is a disk-based virtual tape sys-tem that provides enterprise-class storage management capabilities for MVS-based sys-tems. Its scalable desi...
96257 Sun Confidential: Internal Only xix Revision A ■ Alert Messages Alert messages used within this document are presented as follows: Note: A note provides emphasis or additional useful detail about a topic or proce-dure, and can either precede or follow the information it references. ■ Notationa...
About This Guide xx Sun Confidential: Internal Only 96257 Revision A ■ Where to Find Additional Information Additional information about the complete line of Sun StorageTek products and services is provided through various media, as described below. Reference Documents The VSM5 Virtual Tape Storage ...
96257 Sun Confidential: Internal Only xxi Revision A VSM Engineering Website Extensive and detailed information about VSM, including engineering documents, Red-books, White Papers, and standards, is available through the VSM Engineering website at http://vsm.stortek.com . Website access is restricte...
About This Guide xxii Sun Confidential: Internal Only 96257 Revision A SE Support Tools SE tools, white papers, and other content for use with Sun StorageTek products, including VSM5 system equipment, are available through the SE Support Tools website at http://setools . Website access is restricted...
Planning and Implementation Overview 1-24 Sun Confidential: Internal Only 96257 Revision A ■ Creating Planning Teams Once a sales proposal has been accepted, the Sun customer service manager (CSM) should confer with customer-site personnel including the network administrator, data cen-ter manager, a...
96257 Sun Confidential: Internal Only 1-25 Revision A Planning / Readiness / Implementation Timelines ■ Planning / Readiness / Implementation Timelines The following activity guidelines allow sufficient time for planning, readiness, and imple-mentation tasks to be completed prior to delivery of VSM5...
96257 Sun Confidential: Internal Only 2-27 Revision A 2 Configuration Planning This chapter provides an overview of configuration planning considerations and activities that are used to design a VSM5 system tailored to customer requirements, and to ensure proper implementation of the system. Designi...
Configuration Planning 2-28 Sun Confidential: Internal Only 96257 Revision A ■ Defining Customer Requirements Customized tools are available to assist Sun personnel with estimating customer require-ments and configuring a unique VSM5 system to meet those needs. VSM Quick is a pre-sales tool package ...
96257 Sun Confidential: Internal Only 2-29 Revision A Defining Customer Requirements VSM Sizer Tool As shown in Figure 2-2 , the VSM Sizer tool requests inputs on mount activity, file size, the estimated growth rate of data, and the current configuration of libraries, transports, and cartridges to d...
Configuration Planning 2-30 Sun Confidential: Internal Only 96257 Revision A MVC Sizer Tool As shown in Figure 2-3 , the MVC Sizer tool estimates the number of Multiple Volume Car- tridges (MVCs) required for a VSM installation at intervals of 90 days, 180 days, 270 days, one year, two years, and th...
96257 Sun Confidential: Internal Only 2-31 Revision A Defining Customer Requirements MVC Migration Tool As shown in Figure 2-4 , the MVC Migration tool evaluates existing tape systems, tape me- dia, channels, and data set size to estimate the number of Multiple Volume Cartridges (MVCs) required for ...
Configuration Planning 2-32 Sun Confidential: Internal Only 96257 Revision A CDS Sizer Tool As shown in Figure 2-5 , the CDS Sizer is used to determine size requirements for the HSC control data set (CDS) based on a specific VSM5 system configuration. The tool requests detailed inputs about the VSM ...
96257 Sun Confidential: Internal Only 2-33 Revision A VTSS Configuration Planning ■ VTSS Configuration Planning A VSM5 system consists of Virtual Tape Control System (VTCS) host software, Virtual Tape Storage Subsystem (VTSS) disk hardware (tape buffers) 1 , real tape drives (RTDs) which attach to a...
Configuration Planning 2-34 Sun Confidential: Internal Only 96257 Revision A Model Numbers / Configurations / Capacities Table 2-4. VSM5-VTSS Model Numbers / Configurations / Capacities Base Model Number Disk Arrays Configuration Data Drives * Total Capacity Capacity Feature Code PCap Capacity # Pub...
96257 Sun Confidential: Internal Only 2-35 Revision A VTSS Configuration Planning Prerequisites for FICON Connectivity Note: VTCS 5.1 code or later and VTSS code D01.01.00.17 or higher are required pre-requisites for enabling front-end FICON connectivity between a VTSS and main-frame (host) CPU or F...
Configuration Planning 2-36 Sun Confidential: Internal Only 96257 Revision A Native FICON Attachment Native FICON attachment refers to a FICON CPU channel connected to a FICON control unit interface, which may pass through a FICON director (switch). Since the connection is all-FICON, all channels ca...
96257 Sun Confidential: Internal Only 2-37 Revision A VTSS Configuration Planning FICON Data Transfer Rates The fastest native FICON channels are rated at 200 MB/sec., but actually can achieve a maximum data rate of only 170 MB/sec. under optimum conditions. In actual practice, FI-CON typically oper...
Configuration Planning 2-40 Sun Confidential: Internal Only 96257 Revision A ■ Fibre Channel Cables — Available Lengths Table 2-6. Fibre Channel Cables – Available Lengths Description / Length Part Number LC-LC, 9/125, Duplex, Plenum, 10 meter (32.8 ft.), RoHS-5 10800330 LC-LC, 9/125, Duplex, Riser,...
96257 Sun Confidential: Internal Only 2-41 Revision A Fibre Channel Cables — Available Lengths AC Source Power Specifications and Connectors DC Power Supply Voltage Ripple Specifications Table 2-7. VSM5-VTSS AC Source Power Specifications and Connectors AC Source Power Requirement Power Specificatio...
Configuration Planning 2-42 Sun Confidential: Internal Only 96257 Revision A Power Requirements Table 2-9. VSM5-VTSS Power Requirements — Single AC Source Power Cable Operation Number of 16-Drive Arrays AC Source Voltage In AC Source Amps (Current) In kVA kW Power Factor kBTUs Per Hour 2 264V 10.1A ...
96257 Sun Confidential: Internal Only 3-43 Revision A 3 Implementation Planning This chapter provides an overview of implementation planning activities and tasks, which are designed to ensure a VSM5 system is properly configured, tested, and certified ac-cording to customer requirements. Table 3-1 p...
96257 Sun Confidential: Internal Only 4-45 Revision A 4 Site Readiness Planning This chapter provides information about activities designed to ensure the site is equipped to accommodate the power, safety, environmental, HVAC, and data handling requirements of VSM5 system equipment. Key site readines...
96257 Sun Confidential: Internal Only 4-47 Revision A Site Evaluation – Internal Considerations Transfering Equipment Point-to-Point Site conditions must be verified to ensure all VSM5 system equipment can be safely trans-ported between the delivery dock, staging area, and data center without encoun...
Site Readiness Planning 4-48 Sun Confidential: Internal Only 96257 Revision A Data Center Safety Safety must be a primary consideration in planning installation of VSM5 system equip-ment, and is reflected in such choices as where equipment will be located, the rating and capability of electrical, HV...
96257 Sun Confidential: Internal Only 4-49 Revision A Site Evaluation – Internal Considerations Site Power Distribution Systems The following elements of the site power distribution system should be evaluated when planning an installation of VSM5 system equipment. System Design A properly installed ...
Site Readiness Planning 4-50 Sun Confidential: Internal Only 96257 Revision A Equipment Grounding For safety and ESD protection, VSM5 system equipment must be properly grounded. VTSS cabinet power cables contain an insulated green/yellow grounding wire that con-nects the frame to the ground terminal...
96257 Sun Confidential: Internal Only 4-51 Revision A Site Evaluation – Internal Considerations Electrostatic Discharge Electrostatic discharge (ESD; static electricity) is caused by movement of people, furni-ture, and equipment. ESD can damage circuit card components, alter information on mag-netic...
Site Readiness Planning 4-52 Sun Confidential: Internal Only 96257 Revision A Environmental Requirements and Hazards VSM5 system components are sensitive to corrosion, vibration, and electrical interference in enclosed environments such as data centers. Because of this sensitivity, equipment should ...
96257 Sun Confidential: Internal Only 4-53 Revision A Site Evaluation – Internal Considerations Floor Loading Specifications and References Table 4-3. VSM5-VTSS Floor Loading Specifications Basic Floor Load * Maximum Superimposed Floor Load # 730 kg/m 2 (149 lbs./ft 2 ) 485 kg/m 2 (99 lbs./ft 2 ) No...
Site Readiness Planning 4-54 Sun Confidential: Internal Only 96257 Revision A Raised-Floor Lateral Stability Ratings In areas of high earthquake activity, the lateral stability of raised floors must be consid-ered. Raised floors where VSM5 system equipment is installed must be able to resist the hor...
96257 Sun Confidential: Internal Only 4-55 Revision A Site Evaluation – Internal Considerations Raised-Floor Pedestal Ratings Raised floor pedestals must be able to resist an axial load of 2268 kg (5000 lbs.). Where floor panels are cut to provide service access, additional pedestals may be required...
Specifications and Additional Information A-58 Sun Confidential: Internal Only 96257 Revision A ■ Motherboard and FRU Interconnections – Side 0 Figure A-1. VSM5-VTSS Motherboard and FRU Interconnections – Side 0
96257 Sun Confidential: Internal Only A-59 Revision A Motherboard and FRU Interconnections – Side 1 ■ Motherboard and FRU Interconnections – Side 1 Figure A-2. VSM5-VTSS Motherboard and FRU Interconnections – Side 1
Specifications and Additional Information A-60 Sun Confidential: Internal Only 96257 Revision A ■ Power Safety Grounding Diagram – Side 0 Figure A-3. VSM5-VTSS Power Safety Grounding Diagram – Side 0 A504_022 67 67 67 Legend FRU FRU FRU FRU FRU LineFilter IEC 320 Frame LNG LNG FRU grounded to frame ...
96257 Sun Confidential: Internal Only A-61 Revision A Power Safety Grounding Diagram – Side 1 ■ Power Safety Grounding Diagram – Side 1 Figure A-4. VSM5-VTSS Power Safety Grounding Diagram – Side 1 A504_068 Array PS-1 Power Strip 1 # 16 Pigta il Not a ControlledConnection forSafety Purposes #16 Pigt...
Specifications and Additional Information A-62 Sun Confidential: Internal Only 96257 Revision A ■ Power System Diagram Figure A-5. VSM5-VTSS Power System Diagram
96257 Sun Confidential: Internal Only A-63 Revision A Data Paths and Interfaces ■ Data Paths and Interfaces Figure A-6. VSM5-VTSS Data Paths and Interfaces
96257 Sun Confidential: Internal Only A-65 Revision A Sample IOCP Gen for FICON Configuration ■ Sample IOCP Gen for FICON Configuration Figure A-7. Sample IOCP Gen for FICON Configuration >> NOTE: The example below shows an IOCP gen for a single MVS host connected to a VSM5 throughFICON direct...
Specifications and Additional Information A-66 Sun Confidential: Internal Only 96257 Revision A ■ Virtual Tape Drive Mapping and Host Addressing A VSM5-VTSS can be configured with up to 256 virtual tape drives (VTDs). During VTSS installation, all 256 available VTDs are mapped as shown in Table A-3 ...
96257 Sun Confidential: Internal Only A-67 Revision A FRU Identifiers ■ FRU Identifiers Table A-4. VSM5-VTSS FRU Identifiers Physical Location FRU Common Name FRU Silkscreen FRU Number (Hex) FRU Number (Decimal) FRU Location ID (Unit.Tray.Slot) Power Distribution Units CU Front Tray 0 Power Distribu...
Specifications and Additional Information A-72 Sun Confidential: Internal Only 96257 Revision A ■ Array Drive Module Status Descriptions The Disk Drive / Array Status screen displays the status of each VTSS array drive as a two-character code. The first character defines the partition a specific dri...
FICON Channel Extension Guidelines B-76 Sun Confidential: Internal Only 96257 Revision A ■ Definition of Terms The following terms are used in this appendix: • Front-end – any equipment between a host and a VTSS • Back-end – any equipment between a VTSS and RTD • Channel extension – a configuration ...
96257 Sun Confidential: Internal Only B-77 Revision A General Channel Extension Considerations ■ General Channel Extension Considerations Understand Channel Extension Performance Limitations Channel extension usually involves using a WAN (wide-area network), which possibly op-erates at slower-than-F...
FICON Channel Extension Guidelines B-78 Sun Confidential: Internal Only 96257 Revision A ■ FICON Topologies See “Placement of Extension Equipment” below to determine proper placement of exten- sion equipment for the following FICON topologies: 1. Host-to-VTSS (front-end link to VTDs) a. direct-attac...
96257 Sun Confidential: Internal Only B-79 Revision A FICON Channel Extension – Sample Configurations ■ FICON Channel Extension – Sample Configurations Figure B-1. Host-to-VTSS Channel Extension – Direct Attachment Tape Silo with RTDs Channel Extender VTSS A502_048 z/OSHost Figure B-2. Host-to-VTSS ...
96257 Sun Confidential: Internal Only B-81 Revision A McData/CNT Channel Extension Interoperability ■ McData/CNT Channel Extension Interoperability The following interoperability and configuration information and guidelines apply when us-ing McData/CNT USD-X and Edge3000 channel extenders with a VSM...
96257 Sun Confidential: Internal Only B-83 Revision A Cisco Systems Channel Extension Interoperability ■ Cisco Systems Channel Extension Interoperability The following interoperability and configuration information and guidelines apply when us-ing Cisco Systems channel extension equipment with a VSM...
96257 Sun Confidential: Internal Only C-85 Revision A Glossary A AC . Alternating current. Current in which the direction is reversed, or alternated, 60 times per second (50 times per second in some countries). Contrast with direct cur-rent. acceptance test . A formal test done by a system end- user...
96257 Sun Confidential: Internal Only D-99 Revision A D Forms and Reference Notes This appendix provides electronic forms and worksheets for recording information related to pre-installation planning tasks for a VSM5-VTSS at a specific location, including: • Customer site details • Customer personne...
Sun Confidential: Internal Only Account Information > [electronic form] < Host System Configuration Information > [electronic form] < VTSS Configuration Information > [electronic form] < Account (Company) Name Site Number Street Address City / State / Province / Region Zip or Posta...
Sun Confidential: Internal Only Customer Personnel Contacts > [electronic form] < Account ______________________________________ Data Center Manager (name) Phone Numbers (office / cell) E-Mail Address(es) Other Contact Information Network Administrator (name) Phone Numbers (office / cell) E-Ma...
Sun Confidential: Internal Only Planning Worksheet 1 of 5 > [electronic form] < Account __________________________ Completed By ____________________ Date ___________ Site Readiness Planning Factors Information to Note / Comments 1A. Installation teams defined? 1A. 1B. Installation schedule cre...
Sun Confidential: Internal Only Planning Worksheet 2 of 5 > [electronic form] < Account __________________________ Completed By ____________________ Date ___________ Delivery and Handling Factors Information to Note / Comments 2A. Does the customer have a delivery dock? If NO, where will the V...
Sun Confidential: Internal Only Planning Worksheet 3 of 5 > [electronic form] < Account __________________________ Completed By ____________________ Date ___________ Safety and Fire Prevention Factors Information to Note / Comments 3A. Have all safety and fire-prevention codes and regula- tion...
Sun Confidential: Internal Only Planning Worksheet 4 of 5 > [electronic form] < Account __________________________ Completed By ____________________ Date ___________ Physical Placement Factors Information to Note / Comments 4A. Does the installation area provide sufficient floor space for all ...
Sun Confidential: Internal Only Planning Worksheet 5 of 5 > [electronic form] < Account __________________________ Completed By ____________________ Date ___________ AC Power Factors Information to Note / Comments 5A. Does the installation site have capability for grounding the VTSS cabinet(s)...
Sun Confidential: Internal Only Software Information > [electronic form] < Account ______________________________________ Use this electronic form to record key information (product names, versions, release levels, serial numbers, etc.) for all software 1 used with this VSM solution configurat...
Sun Confidential: Internal Only Hardware Information – Tape Devices > [electronic form] < Account ______________________________________ Use this electronic form to record key information (product names, model numbers, serial numbers, etc.) for all tape device hardware 1 used with this VSM sol...
Sun Confidential: Internal Only Hardware Information – Switches / Routers > [electronic form] < Account ______________________________________ Use this electronic form to record key information (product names, model numbers, serial numbers, etc.) for all ex-ternal switches, routers, or other h...
Sun Confidential: Internal Only Hardware Information – SDP and Modem Devices > [electronic form] < Account ______________________________________ Use this electronic form to record key information (product names, model numbers, serial numbers, etc.) for all Ser-vice Delivery Platform (SDP) and...
Sun Confidential: Internal Only Notes / Additional Information > [electronic form] < Account ______________________________________
SUN™ THE NETWORK IS THE COMPUTER ©2006 Sun Microsystems, Inc. All rights reserved. Sun, Sun Microsystems, and the Sun logo are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. Sun Microsystems, Inc. 4150 Network Circle, Santa Clara, CA 95054 USA...
Sun Microsystems Manuals
-
Sun Microsystems B1600
Manual
-
Sun Microsystems 7
Manual
- Sun Microsystems V120 Manual
-
Sun Microsystems AC200
Manual
-
Sun Microsystems Sun Quad
Manual
- Sun Microsystems 60 Manual
-
Sun Microsystems SG-XPCIE1FC-EM8-Z
Manual
-
Sun Microsystems 10
Manual
-
Sun Microsystems 4000
Manual
-
Sun Microsystems T3
Manual
-
Sun Microsystems 819468310
Manual
-
Sun Microsystems 2000E
Manual
-
Sun Microsystems SPARCcenter 2000
Manual
-
Sun Microsystems X4140
Manual
-
Sun Microsystems X6250
Manual
- Sun Microsystems 2500 Manual
-
Sun Microsystems GigaSwift Ethernet Adapter
Manual
-
Sun Microsystems 805-7945-10
Manual
-
Sun Microsystems A5000
Manual
-
Sun Microsystems X4240
Manual