Page 2 - CONTENTS; INSTALLATION
2 | DEL Plus AU www.stiebel-eltron.com CONTENTS SPECIAL INFORMATIONOPERATION 1. General information �����������������������������������������3 1.1 Safety instructions ����������������������������������������������� 3 1.2 Other symbols in this documentation ����������������������� 4 1.3 Units of meas...
Page 3 - SPECiAL iNfOrmATiON; General information; Note; Safety instructions; KEYWORD Type of risk
www.stiebel-eltron.com DEL Plus AU | 3 SPECiAL iNfOrmATiON | OPErATiON General information SPECiAL iNfOrmATiON - The appliance may be used by children aged 3 and older and persons with reduced physical, sensory or mental capabilities or a lack of ex- perience and know-how, provided that they are sup...
Page 4 - Other symbols in this documentation; Units of measurement; Appliance description
OPErATiON Safety 4 | DEL Plus AU www.stiebel-eltron.com 1.2 Other symbols in this documentation Note General information is identified by the adjacent symbol. f Read these texts carefully. Symbol meaning Material losses (appliance damage, consequential losses and environmen- tal pollution) Appliance...
Page 5 - Heating system; Settings and displays; Selecting the set temperature; Temperature limit via internal anti-scalding
OPErATiON Settings and displays www.stiebel-eltron.com DEL Plus AU | 5 You can store different set temperatures and call them up quickly. With the ECO function, the flow rate is limited to 3 preset levels. The appliance has setting options for a temperature limit (Tmax function, user) and internal a...
Page 6 - Allocating temperature memory buttons; Selecting ECO level; Inlet temperature information; Saving energy
OPErATiON Settings and displays 6 | DEL Plus AU www.stiebel-eltron.com 4.5 Temperature limit Tmax (user) The temperature limit allows you as a user to restrict the adjusta- ble set temperature at the appliance to a maximum value. Your qualified contractor can set an additional temperature limit for ...
Page 7 - iNSTALLATiON; General safety instructions
www.stiebel-eltron.com DEL Plus AU | 7 OPErATiON | iNSTALLATiON Cleaning, care and maintenance 5. Cleaning, care and maintenance f Never use abrasive or corrosive cleaning agents. A damp cloth is sufficient for cleaning the appliance. f Check the taps regularly. Limescale deposits at the tap out- le...
Page 8 - Test for delivery temperature performance; Appliance description; Standard delivery; Wireless remote control; Installation location; Material losses; Minimum clearances
iNSTALLATiON Appliance description 8 | DEL Plus AU www.stiebel-eltron.com Test for delivery temperature performance The appliance is to be tested according to AS 3498 as a 50 °C- limited water heater. The option 1 illustrated in figure A.1 of the Appendix A applies to the appliance. Inlet Water he...
Page 9 - Water installation; Standard installation
iNSTALLATiON installation www.stiebel-eltron.com DEL Plus AU | 9 9.3 Water installation f Flush the water line thoroughly. Taps/valves Use appropriate pressure taps. Open vented taps are not per- missible. Permissible water line materials - Cold water inlet line: Pipes made from galvanised steel, st...
Page 10 - Preparing the water connection
iNSTALLATiON installation 10 | DEL Plus AU www.stiebel-eltron.com Preparing the water connection ! Material losses Carry out all water connection and installation work in accordance with regulations. 24 5 Nm 24 5 Nm 19 5 Nm 19 5 Nm D 00000 41 72 0 f Remove the caps from the tees. f Fit the plugs and...
Page 11 - Internal anti-scalding protection via jumper slot
iNSTALLATiON Commissioning www.stiebel-eltron.com DEL Plus AU | 11 ! Material losses Observe the type plate. The specified rated voltage must match the mains voltage. f Connect the power cable to the mains terminal. D 00000 53 28 6 2 3 1 1 Lower back panel section 2 Connection piece in the standard ...
Page 12 - Fit the appliance cover; Recommissioning; Appliance shutdown; Overview of the alternative types of installation; Electrical connection from above on unfinished
iNSTALLATiON Appliance shutdown 12 | DEL Plus AU www.stiebel-eltron.com Fit the appliance cover D 00000 40 77 7 1 2 3 4 1 Pipe knock-out 2 Cover guides 3 Back panel guides 4 Fixing screw (not part of the standard delivery) f Cleanly cut or break out the knock-out openings in the appli- ance cover. I...
Page 13 - WARNING Electrocution; Electrical connection on unfinished walls with; Water installation on unfinished walls
iNSTALLATiON Alternative installation methods www.stiebel-eltron.com DEL Plus AU | 13 D 00000 53 28 2 1 1 Cable routing f Reposition the mains terminal from the bottom to the top. To do this, undo the fixing screw. Turn the mains terminal with connecting cables 180° clockwise. Route the cable around...
Page 14 - Wall mounting bracket when replacing an; Replacing a DHF instantaneous water heater; Installation with offset tiles
iNSTALLATiON Alternative installation methods 14 | DEL Plus AU www.stiebel-eltron.com D 00000 43 29 1 f Fit the strainer and the plastic profile washer in the tee for the cold water inlet. ! Material losses The strainer must be fitted for the appliance to function. f When replacing an appliance, che...
Page 15 - Operation with preheated water; Service information; Overview of connections
iNSTALLATiON Service information www.stiebel-eltron.com DEL Plus AU | 15 13.8 Operation with preheated water You can restrict the maximum inlet temperature by installing a central thermostatic valve. 13.9 Horizontal installation of the appliance Note For the horizontal installation alternative, plea...
Page 16 - Fault code display
iNSTALLATiON Troubleshooting 16 | DEL Plus AU www.stiebel-eltron.com 15. Troubleshooting WARNING Electrocution To test the appliance, it must be connected to the power supply. Note When testing the appliance using the diagnostic traffic lights, water must be flowing. indicator options for diagnostic...
Page 17 - Draining the appliance; Dimensions and connections; Alternative connection options
iNSTALLATiON maintenance www.stiebel-eltron.com DEL Plus AU | 17 16. Maintenance WARNING Electrocution Before any work on the appliance, disconnect all poles from the power supply. This appliance contains capacitors which are discharged when disconnected from the power supply. The capacitor discharg...
Page 18 - Application areas / Conversion table; Sizing the pipework; Fault conditions
iNSTALLATiON Specification 18 | DEL Plus AU www.stiebel-eltron.com 17.2 Wiring diagram 3/PE ~ 380-415 V D 00000 53 42 4 1 3 4 2 1 Power PCB with integral safety switch 2 Bare wire heating system 3 High limit safety cut-out 4 Mains terminal 17.3 DHW output The DHW output is subject to the connected p...
Page 19 - Guarantee; ENVIRONMENT AND RECYCLING
iNSTALLATiON Specification www.stiebel-eltron.com DEL Plus AU | 19 iNSTALLATiON | ENVIRONMENT AND RECYCLING Specification 17.7 Data table DEL 13 Plus AU DEL 18 Plus AU DEL 27 Plus AU 234470 236741 236742 Electrical dataRated voltage V 380 400 415 380 400 415 380 400 415 Rated output kW 12.2 13.5 14....
Page 20 - WARRANTY; UMWELT UND RECYCLING
20 | DEL Plus AU www.stiebel-eltron.com WARRANTY UMWELT UND RECYCLING UMWELT UND RECYCLING GARANTIE GARANTIE Who gives the warranty 1. The warranty is given by Stiebel Eltron (Aust) Pty Ltd (A.B.N. 82 066 271 083) of 294 Salmon Street, Port Melbourne, Victoria, 3207 (“we”, “us” or “our”). The warran...
Page 21 - NOTES