Page 2 - CONTENTS; INSTALLATION
2 | DEL Plus AU www.stiebel-eltron.com CONTENTS SPECIAL INFORMATIONOPERATION 1. General information �����������������������������������������3 1.1 Safety instructions ����������������������������������������������� 3 1.2 Other symbols in this documentation ����������������������� 4 1.3 Units of meas...
Page 3 - SPECiAL iNfOrmATiON | OPErATiON; SPECiAL iNfOrmATiON; General information; Note; Read these instructions carefully before using the appli-; Safety instructions; KEYWORD Type of risk
EN GL ISH www.stiebel-eltron.com DEL Plus AU | 3 SPECiAL iNfOrmATiON | OPErATiON General information SPECiAL iNfOrmATiON - The appliance may be used by children aged 3 and older and persons with reduced physical, sensory or mental capabilities or a lack of ex- perience and know-how, provided that th...
Page 4 - Other symbols in this documentation; Units of measurement; Appliance description
OPErATiON Safety 4 | DEL Plus AU www.stiebel-eltron.com 1.2 Other symbols in this documentation Note General information is identified by the adjacent symbol. f f Read these texts carefully. Symbol meaning Material losses (appliance damage, consequential losses and environmen- tal pollution) Applian...
Page 5 - GL; Heating system; Settings and displays; Setting the temperature; Setting the Tmax temperature limit; Enabling the temperature limit
OPErATiON Settings and displays EN GL ISH www.stiebel-eltron.com DEL Plus AU | 5 ance or you make a change on the user interface. The backlight switches off automatically 5 seconds after water stops flowing or if no operation has been performed for 30 seconds.You can set the temperature unit and ope...
Page 6 - Allocating temperature memory buttons; Selecting ECO level; Inlet temperature information; Saving energy
OPErATiON Cleaning, care and maintenance 6 | DEL Plus AU www.stiebel-eltron.com 4.6 Allocating temperature memory buttons Memory buttons "1" and "2" can each be assigned a required temperature. f f Select the required temperature. f f To store the required temperature, press and hold...
Page 7 - iNSTALLATiON; General safety instructions
iNSTALLATiON Safety EN GL ISH www.stiebel-eltron.com DEL Plus AU | 7 Note After a power failure Programming unit displays and selected settings are re- tained following a power failure. If you cannot remedy the fault, contact your qualified contractor. To facilitate and speed up your request, provid...
Page 8 - Appliance description; Standard delivery; Wireless remote control; Installation location; Material losses; Minimum clearances; Permissible water line materials
iNSTALLATiON Appliance description 8 | DEL Plus AU www.stiebel-eltron.com 8. Appliance description 8.1 Standard delivery The following are delivered with the appliance: - Wall mounting bracket - Installation template - 2 plugs - 2 extensions - 2 caps - 2 tees - 8 flat gaskets - Strainer - Plastic pr...
Page 9 - Standard installation; Opening the appliance
iNSTALLATiON installation EN GL ISH www.stiebel-eltron.com DEL Plus AU | 9 10. Installation factory set tings DEL 13 Plus AU DEL 18 Plus AU DEL 27 Plus AU Internal anti-scalding protection Tmax (= 50 °C) Tmax (= 50 °C) Tmax (= 50 °C) Standard installation DEL 13 Plus AU DEL 18 Plus AU DEL 27 Plus AU...
Page 10 - Installing the appliance
iNSTALLATiON installation 10 | DEL Plus AU www.stiebel-eltron.com Installing the appliance Note If you are installing the appliance with flexible pipe con- nections, also secure the bottom of the back panel with a screw. D 00000 77 72 8 1 2 1 Cable entry installation aid 2 Cable grommetUse the insta...
Page 11 - Internal anti-scalding protection via jumper slot; Fit the appliance cover
iNSTALLATiON Commissioning EN GL ISH www.stiebel-eltron.com DEL Plus AU | 11 11. Commissioning 11.1 Preparation 43 °C Tmax D 00000 77 02 0 1 1 Jumper for anti-scalding protection setting Internal anti-scalding protection via jumper slot Jumper position Description 43 °C Tmax Factory setting (50 °C) ...
Page 12 - Recommissioning; Appliance shutdown; Overview of the alternative types of installation; Electrical connection from above on unfinished
iNSTALLATiON Appliance shutdown 12 | DEL Plus AU www.stiebel-eltron.com D 000 00 53 28 1 f f Switch on the power supply. 11.2.1 Appliance handover f f Explain the appliance function to users and familiarise them with how it works. f f Make the user aware of potential dangers, especially the risk of ...
Page 13 - Electrical connection on unfinished walls with; Water installation on unfinished walls
iNSTALLATiON Alternative installation methods EN GL ISH www.stiebel-eltron.com DEL Plus AU | 13 13.2 Electrical connection on unfinished walls with short power cable D 00000 60 38 7 f f Reposition the mains terminal further downwards. To do this, undo the fixing screw. Secure the mains terminal in p...
Page 14 - Wall mounting bracket when replacing an; Replacing a DHF instantaneous water heater; Installation with offset tiles; Service information; Overview of connections
iNSTALLATiON Service information 14 | DEL Plus AU www.stiebel-eltron.com ! Material losses The cover plate of the lower back panel section must not bend when installed. 13.5 Wall mounting bracket when replacing an appliance An existing STIEBEL ELTRON wall mounting bracket may be used when replacing ...
Page 15 - Appliance cover retainer; The diagnostic traffic light is displayed when water flows.
iNSTALLATiON Troubleshooting EN GL ISH www.stiebel-eltron.com DEL Plus AU | 15 Appliance cover retainer D 00000 56 21 6 15. Troubleshooting WARNING Electrocution To test the appliance, it must be connected to the power supply. Display indication Cause E1 | Spanner Fault in electronic safety circuit....
Page 16 - WARNING Electrocution; Dimensions and connections; Alternative connection options
iNSTALLATiON maintenance 16 | DEL Plus AU www.stiebel-eltron.com 16. Maintenance WARNING Electrocution Before any work on the appliance, disconnect all poles from the power supply. Draining the appliance The appliance can be drained for maintenance work. WARNING Burns Hot water may escape when you d...
Page 17 - Application areas / Conversion table; Sizing the pipework; Fault conditions
iNSTALLATiON Specification EN GL ISH www.stiebel-eltron.com DEL Plus AU | 17 17.2 Wiring diagram 3/PE ~ 380-415 V D 00000 53 42 4 1 3 4 2 1 Power PCB with integral safety switch 2 Bare wire heating system 3 High limit safety cut-out 4 Mains terminal 17.3 DHW output The DHW output is subject to the c...
Page 18 - Guarantee
iNSTALLATiON Specification 18 | DEL Plus AU www.stiebel-eltron.com 17.7 Data table DEL 13 Plus AU DEL 18 Plus AU DEL 27 Plus AU 234470 236741 236742 Electrical dataRated voltage V 380 400 415 380 400 415 380 400 415 Rated output kW 12.2 13.5 14.5 16.2 18 19.4 23.5 26 28 Rated current A 18.5 19.5 20....
Page 19 - WARRANTY; WArrANTY
EN GL ISH www.stiebel-eltron.com DEL Plus AU | 19 WARRANTY D0000053038 Who gives the warranty 1. The warranty is given by Stiebel Eltron (Aust) Pty Ltd (A.B.N. 82066 271 083) of 294 Salmon Street, Port Melbourne, Victoria, 3207 (“we”, “us” or “our”). The warranty 2. This warranty applies to the Stie...