Page 3 - WARNING; Read all instructions before using unit.
WARNING WARNING Risk of fire. Highly flammable material. W881 Read all instructions before using unit. WARNING FOR YOUR SAFETY, the information in this manualmust be followed to minimize the risk of fire or ex-plosion or to prevent property damage, personal in-jury or death. W033 WARNING • Do not st...
Page 5 - Table of Contents; Dimensions
Table of Contents Dimensions ............................................................................................. 6 Installation ............................................................................................. 8 Before You Start ....................................................
Page 6 - Electric Dryers
Dimensions Electric Dryers A 22.38 in. [569 mm] B 8.0 in. [203 mm] C * 36 in. [914 mm] D (to controls) Electronic Control: *41.25 in. [1048 mm] Knob Control: *40.75 [1035 mm] E * 42.75 in. [1086 mm] F 15.4 in. [391 mm] G * 15.44 in. [392 mm] H 26.875 in. [683 mm] I * 4.0 in. [102 mm] J 0.4 in. [11 m...
Page 7 - Gas Dryers
Gas Dryers 1. 3/8 in. N.P.T. Gas Connection A 22.38 in. [569 mm] B 8.0 in. [203 mm] C * 36 in. [914 mm] D Electronic Control: *41.25 in. [1048 mm] Knob Control: *40.75 [1035 mm] E * 42.75 in. [1086 mm] F 15.4 in. [391 mm] G * 15.44 in. [392 mm] H * 2.8 in. [70 mm] I 2.3 in. [60 mm] J 26.875 in. [683...
Page 8 - Before You Start; Supplies; Figure 1; Parts Included; Position and Level the Dryer
Installation Before You Start Supplies For most installations, the basic supplies you will need are: DRY2586N_SVG 8 7 6 5 4 3 2 1 1. Wrench 2. 1/4 inch Driver 3. Screwdrivers 4. Level 5. Gloves 6. Teflon Tape 7. Duct Tape 8. Safety Glasses Figure 1 NOTE: This appliance is suitable for use in countri...
Page 11 - Table 1; Steam Dryers - Connect Water Inlet
Area Description Free Standing/Alcove In- stallation Closet Installation A* Dryer sides and rear clearance 0 in. [0 mm] 0 in. [0 mm] B Dryer top clearance 12.25 in. [305 mm] 12.25 in. [305 mm] C Dryer front clearance Not Applicable 2 in. [51 mm] D Exhaust duct clearance to com-bustible material 2 in...
Page 12 - Connect Dryer Exhaust System; Figure 4
11. Check that Y-connector valves are open (if applicable).12. Turn water on and check for leaks. Wait 30 minutes and check again, some leaks are slow to show up. 13. If leaks are found, check and retighten the hose couplings. NOTE: If leaks persist after checking and retighten-ing hose coupling, ch...
Page 13 - Number of 90° Elbows; Table 2
• Exhaust duct must not be connected to any other duct, vent, or chimney. • Dryer exhausts 220 cfm per unit (measured at back of dryer).• DO NOT install flexible duct in concealed spaces, such as a wall or ceiling. • Static pressure in exhaust duct should not be greater than 0.6 inches water column ...
Page 14 - Gas Dryers - Connect Gas Supply Pipe; Make certain your dryer is equipped for use with the type of
NOTE: The maximum length of a 4 in. [102 mm] diame-ter flexible metal duct must not exceed 7.87 ft. [2.4 m],as required to meet UL2158, clause 7.3.2.A. Gas Dryers - Connect Gas Supply Pipe WARNING To reduce the risk of gas leaks, fire or explosion: • The dryer must be connected to the type of gas as...
Page 15 - Altitude; Table 4; Connect Electrical Plug (Electric Dryer; Grounding Information
D233I_SVG 2 3 4 1 5 1. New Stainless Steel Flexible Connector – (Use designCSA certified connector) Use only if allowed by local co-des 2. 1/8 in. NPT Pipe Plug 3. Equipment Shut-Off Valve 4. Black Iron Pipe: Shorter than 20 ft. [6.1 m] – Use 3/8 in. [9.5 mm] pipe. Longer than 20 ft. [6.1 m] – Use 1...
Page 16 - Table 5; Table 5; Connecting Power Cord with Three-Wire Plug
WARNING Improper connection of the equipment-groundingconductor can result in a risk of electric shock.Check with a qualified electrician or service person ifyou are in doubt as to whether the dryer is properlygrounded. W038 Do not modify the plug proivded with the cord-kit - if it will notfit the o...
Page 18 - Connecting Power Cord with Four-Wire Plug
3. Use a strain relief and insert end of power cord through power supply hole. D696I_SVG Figure 8 4. Use the three screws from the accessories bag to attach the power cord wires to the terminal block. Refer to Figure 9 . 3-Wire Connection DRY2508N_SVG 4 3 2 1 1. "L1" Terminal 2. Neutral Term...
Page 19 - Reverse Door, if Desired; NOTE: Doors with windows cannot be reversed.
DRY2468N_SVG 1 1. Earth/Ground Screw Figure 12 4. Use a strain relief and insert end of power cord through power supply hole. DRY2469N_SVG 1. Strain Relief Figure 13 5. Attach power cord earth/ground (green) wire to rear bulkhead using earth/ground screw removed in Step 3. 4-Wire Connection DRY2482N...
Page 21 - Electric Dryer; Electric; Connect to 30 Amp circuit.
8. Using screwdriver, remove two door plugs, and reinstall on opposite side of door opening. D317S_SVG Figure 22 9. Reinstall four hinge attaching screws, removed in Step 1. D606I_SVG Figure 23 Wipe Out Inside of Dryer Before using dryer for the first time, use an all-purpose clean-er, or a detergen...
Page 22 - Recheck Steps
• Do not overload circuits.• Do not use an adapter.• Do not use an extension cord.• Do not operate both a washer and gas dryer on the same cir- cuit. Use separately fused 15 amp circuits. The dryer is designed to be operated on a separate branch, polar-ized, three-wire, effectively grounded, 120 Vol...
Page 24 - Fast Track for Installing the Dryer; Refer to the manual for more detailed information.
Installer Checklist Fast Track for Installing the Dryer 1 Position and Level theDryer. DRY2634N_SVG 6 Reverse Door, if De-sired. D675I_SVG1 CHECK CHECK 2 STEAM MODELSONLY Connect Water InletHose. DRY2866N_SVG1 COLD HOT C H DRY2869N_SVG1 COLD HOT C H 7 Wipe Out Inside ofDryer. CHECK CHECK 3 Connect D...