Page 2 - Table of Contents; Specifications of SNMP Installation
FWD-S42H1 Table of Contents 3. ID Talk 1. Default Setting.................................................................. 33 2. Setting Items ..................................................................... 34 3. Packet Structure...................................................................
Page 3 - Section 1
FWD-S42H 1. Communication Parameters Communication method RS-232C Synchronous method Asynchronous Baud rate 9600bps Character length 8bit Parity None Start bit length bit Stop bit length bit Flow control None 2. Pin Assignment 3. Communication Data Format (a) Control message No. Item Value Header 0x...
Page 4 - Control answer
2 FWD-S42H (b) Enquiry message No. Item Value Header 0x83: Enquiry 2 Category 0xXX 3 Function 0xXX 4 Data 0xFF 5 Data2 0xFF 6 Check Sum 0xXX * Check Sum: Sum total of to X, lower one-byte data is validated when a value exceeds 255 (byte). (c) Answer message 1 Control answer No. Item Value Header 0x7...
Page 5 - Error answer
3 FWD-S42H 4 Error answer No. Item Value Header 0xE0: Answer 2 Answer * 0x00: No Function Error 0x0: Check Sum Error 0x02: Data Length Error 3 Check Sum 0xXX * 0x00: No Function Error Packet header,category or function code are not included in this protocol. 0x0: Check Sum Error Check sum value of r...
Page 10 - Analog Signal Detect Function
8 FWD-S42H Code Table (1-a) [a]Function [b]Range/Switch Code Command Control Enquiry Standby Power On 0x7E On Screen Logo 0x00 OFF Yes Yes Enable Enable 0x0 ON (Default) 0x02 Reserved 0x7F LED 0x00 OFF Yes Yes Disable Enable 0x0 ON 0x8 Power On Delay 0x00-0x78 sec x Data Yes Yes Enable Enable * : Au...
Page 11 - Priority Signal Select Function
9 FWD-S42H 6. Priority Signal Select Function (a) Mode Control Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 Code Table (2-a) [a] Code Table (2-d) 0xFF 0xXX Answer Header Answer Return to Data Size Return Data1 Data2 Check Sum Enquiry 0x70 0x00 0x02 Code Table (2-a) [b] 0xF...
Page 12 - Year Set
0 FWD-S42H Year Set Syntax Header Category Function Data1 Data2 Check Sum Control 0x8C 0x00 0x7B 0x02 Year: 0x00-0x63 0xXX Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x7B 0xFF 0xFF 0xFC Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x0 0x7 Limit Ov...
Page 15 - Player IP Address
3 FWD-S42H Player IP Address Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x83 0xFF 0xFF 0x04 Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x03 0x73 Command Canceled Answer Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum Enquiry 0x8...
Page 20 - Arrangement of Multi Position.
8 FWD-S42H * 1 Arrangement of Multi Position. Multi Position (2 x 2) Multi Position (1 x 2) Multi Position (2 x 1) Multi Position (3 x 3) Multi Position (1 x 3) Multi Position (3 x 1) Multi Position (4 x 4) Multi Position (1 x 4) Multi Position (4 x 1) 1 2 4 3 1 2 1 2 1 2 5 3 6 4 8 9 7 3 2 1 1 2 3 1...
Page 23 - For function 0x0A, 0x0B and 0x0D in the left table; When the display value is 50
2 FWD-S42H (d) Soft Version (Main CPU/LAN) Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 Code Table 0xFF 0xFF 0xB4 (4-k) Answer Header Answer Return to Data Size Return Data1 Return Data2 Check Sum Enquiry 0x70 0x00 Code Table Upper 8bit Data Lower 8bit Data 0xXX Completed ...
Page 29 - efficiently monitored using these protocols.
27 FWD-S42H1 Section 2 SNMP 1. SNMP FWD-S42H1/S47H1 installs SNMP (Simple Network Management Protocol). SNMP is a standard protocol for network management that was standardized in IETF (Internet Engineer Task Force).By using SNMP, the management information of equipment connected to a network can be...
Page 30 - Specifications of SNMP Installation; GetRequesat; Operation of SNMP Setting Window
28 FWD-S42H1 SNMP Setting window (on Web Page) 2. Specifications of SNMP Installation The specifications of the SNMP agent installed in this unit are shown in below. . SNMP version: SNMPv1 . MIB definition: SMIv2 . Support PDU: GetRequesat SetRequest GetNextRequest Trap . Standard MIB to be installe...
Page 31 - Trap destinations; Up to four Trap destinations can be set to one Community.; Setting procedure of Community
29 FWD-S42H1 4-1. Community A Community name is used as the password for SNMP access. The request received from an SNMP man-ager is accepted when the Community name contained in the request coincides with the Community name set. The request is rejected when the former does not coincide with the latt...
Page 32 - Up to four IP restrictions can be set.
30 FWD-S42H1 Editing of Community 1. Select the Community, you want to edit, from a drop-down list.2. Click the [Edit] button. The “Community name”, “Rights”, and “Trap destinations” text boxes, and [Set|To|List] and [Cancel] buttons are validated. Edit the Community name when you want to edit a Com...
Page 33 - MIB to Be Installed; Refer to RFC1213 for the detailed definition of MIB-2.; Information to Be Notified on Trap
31 FWD-S42H1 5. MIB to Be Installed This unit installs MIB-2.MIB-2 is the most representative standard MIB. It is installed in various network products. The statistical information on the amount of network traffic or the number of transmitted and received packets is defined, and the change or transi...
Page 34 - Section 3
33 FWD-S42H1 ID Talk is set as described below. ID Talk is a protocol for operating the function of this unit via a net-work. 1. Default Setting Item Description Transport TCP Port number 53484 (Factory setting) TCP connection time-out 30 seconds (Factory setting) Section 3 ID Talk
Page 35 - The items that can be set to ID Talk are shown in the table below.; Set the items described above properly on the SETUP; Version; Indicates the version number of an ID Talk protocol.; Category
34 FWD-S42H1 Community (4) Command (4) Data (n) Header (2) 0 0 Version (8) Category (8) 1 (Bit position) 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 2. Setting Items The items that can be set to ID Talk are shown in the table below. Item Description Start ID Talk Service Select the check box when using ID Talk. C...
Page 36 - is embedded with 00h.
35 FWD-S42H1 0 0 Community (32) 1 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 2 3 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 (Bit position) 0 0 Item No(16) Data Length(8) Request/Response(8) 1 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 2 3 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 (Bit position) 3-2. Community A request is executed when community...
Page 37 - Requests and Responses; Requests and responses are described below.
36 FWD-S42H1 Set Data(n byte) 00h Item No. n Request Request Item No. Data Data Length Get Data(n byte) OK(01h) Item No. n Response 01h Item No. 0 Request Request Item No. Data Length Get Data(n byte) OK(01h) Item No. n Response 4. Requests and Responses Requests and responses are described below. 4...
Page 38 - bytes
37 FWD-S42H1 Error Code(16) NG(00h) Item No. 2 4-5. ERROR response An NG message is returned as a response when an error occurs in the contents of a request or the result of execution. ERROR response 5. Items Category Contents SET GET 80 ** h Gets the information of this unit O O 90 ** h Gets the ne...
Page 40 - An error code list and its details are shown in the table below.; When Item No. that is not supported is specified
39 FWD-S42H1 6. Error Codes An error code list and its details are shown in the table below. Category Error Error code Item Error (01 ** h) Invalid Item 01h Invalid Item Request 02h Invalid Length 03h Invalid Data 04h Short Data 11h Not Applicable Item 80h Community Error (02 ** h) Different Communi...