Page 2 - SERVICE ADJUSTMENT MODE ON; SERVICE ADJUSTMENT MODE MEMORY; SECTION 4: CIRCUIT ADJUSTMENTS; Test Equipment Required:; MUTING
— 15 — KV-32FV27 / 36FS13 / 36FS17 / 36FV27/ 38FS17 4-2. MEMORY WRITE CONFIRMATION METHOD 1. After adjustment, pull out the plug from the AC outlet, then replace the plug in the AC outlet again. 2. Turn the power switch ON and set to Service Mode. 3. Call the adjusted items again to confi rm they wer...
Page 3 - VP
— 16 — KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 4-4. ADJUSTMENT ITEMS (1 OF 6) Description Data Adj/Fix Initial 32" 36"/38" Comments Range Data FV FS FV 0 HPOS H-Position 0-63 Adj 7 7 7 0: 2ms delay, 63: 2ms advance 1 HSIZ H-Size 0-63 Adj 1010 10 EW DC bias, 0: -0.5V, 31: 0V, 63: +0...
Page 4 - SRS
— 17 — KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 ADJUSTMENT ITEMS (2 OF 6) Description Data Adj/Fix Initial 32" 36"/38" Comments Range Data FV FS FV Register Name 48 YSPF Sharpness fo for YUV Input 0,1 FIX 1 1 0=2.5MHZ, 1=3.0MHz 49 AXNT Axis NTSC 0,1 FIX 00 0: Japan Axis, 1: US Axis ...
Page 6 - PIC IMP; PIP
— 19 — KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 ADJUSTMENT ITEMS (4 OF 6) Description Data Adj/Fix Initial 32" 36"38" Comments Range Data FV FS FV Register Name 7 GCUR Controls Curve of Gamma Correction 0,1 FIX 00 0: -2.4dB, -1.6dB 8 BLKC Black Conpensation 0,1 FIX 1 1 OFF 9 TEST Te...
Page 7 - DAC
— 20 — KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 ADJUSTMENT ITEMS (5 OF 6) Description Data Adj/Fix Initial 32" 36"/38" Comments Range Data FV FS FV Register Name 20 PUGA Peak Level U Output 0-255 FIX 52 52 0: 0.3Vpp, 192: 1.0Vpp, 255: 1.2Vpp 21 4PUG Peak Level U Output YUV Input 0-2...
Page 8 - Vivid; VALUE; WARM; MAP
— 21 — KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 ADJUSTMENT ITEMS (6 OF 6) 4-5. FEATURE ID MAP SERVICE 00011000 7 IDID7 24 TV M306V5ME-1015PVERSION: 1.0__ NVM:G Note: Check to be sure NVM is good (NVM: G) 0RGHO 'HVWLQDWLRQ ,' ,' ,' ,' ,' ,' ,' ,' .9)9 86 .9)9 &1' .9)6 86 .9)6 &1' .9)6 +$...
Page 9 - Example; T2HU and T2CO are for Tuner inputs.
— 22 — KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 TO PROGRAM PROGRAM PALETTE RESET LEVELS 1. Switch to Program Palette to edit. 2. Enter Service Mode. 3. Set desired values for current Program Palette settings. 4. Write into memory by pressing MUTING then ENTER . 5. Repeat steps 1-4 for each pale...
Page 11 - ROTATION COIL ADJUSTMENT; Favorite Channel
— 24 — KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 ROTATION COIL ADJUSTMENT 1. Input a monoscope signal. 2. Push the Menu button on the Remote. 3. Select the “Set-up” mode. 4. Select “Tilt Correction”. Confi rm that number (0) color changes to red. 5. Push (+) on the Remote. Confi rm that the number...