Page 2 - TABLE OF CONTENTS
TABLE OF CONTENTS OPERATION AND MAINTENANCE…………..………..…………………………………….....1-12 Instructions before Use ……………………………………………………………………………1-2 Description of Air Conditioner Components………………………………………………...………3 Remote Control Operation…………………………………………………………………………4-6 How to Insert Batteries…………………………………………………...
Page 3 - Operation and Maintenance; Instructions before Use
- 1 - Operation and Maintenance ◆ Instructions before Use Carefully read the following instructions before use Warning ★ Do not use flammable liquids on or near this air conditioner. ★ Touching metal parts after removing filter can cause an electric shock. ★ Do not use for long periods of time if th...
Page 5 - Description of Air Conditioner Components; Air intake; Signal Sensor
- 3 - ◆ Description of Air Conditioner Components Air intake Air outlet On/Off Switch Connecting Pipe / Line set On/Off Switch Signal Sensor
Page 8 - How to Insert Batteries; The remote control uses two AAA batteries.
- 6 - ◆ Remote Control Operation (Continued) The General Procedure: 1. Press ON/OFF button to start the unit. 2. Press MODE button to select the suitable operation mode. 3. Press SWING button to swing. It will stop when pressed again. 4. Press FAN button to set desired fan speed. 5. Press +/- button...
Page 9 - User Notices
- 7 - ◆ User Notices ★ Select the most comfortable temperature. ★ The airflow direction can be adjusted. At operating, adjust the vertical airflow direction by adjusting the louvers of upward/downward direction. And then, hold two ends of left and right louver to adjust the horizontal airflow. ★ Don...
Page 10 - Care and Maintenance; Cleaning the Air Filters (Recommended once every three months); Take down the air filter
- 8 - ◆ Care and Maintenance CAUTION: Turn power off and pull out the power cord before cleaning air conditioner. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock. Volatile Liquid (e.g. thinner or gasoline) will damage the air condition...
Page 11 - Reinsert the filters; Check before Use; This is caused by the odors in the room.
- 9 - ◆ Care and Maintenance (Continued) 3. Reinsert the filters Reinsert the filters along the direction of arrow, then cover the surface panel and clasp it. Check before Use 1. Be sure that nothing obstructs the air outlet and intake vents. 2. Verify that the unit is properly grounded. 3. Always u...
Page 13 - Specifications and Technical Data; Model
- 11 - ◆ Specifications and Technical Data Model KFHHP-22-ID / KFHHP-22-OD Function Heating and Cooling Cooling capacity(BTU/hr) & (Watts) 22000 / 6450 (2250-7000) Heating capacity(BTU/hr) & (Watts) 24200 / 7100 (1650-8500) Rated voltage 208-230V ~ Rated Frequency 60Hz Cooling/Heating rated ...
Page 14 - Installation Services; Installation Diagram; Important Notes; The installation must be done by trained and
- 12 - Installation Services ◆ Installation Diagram Important Notes The installation must be done by trained and qualified service personnel.
Page 15 - Avoid a location where there is heat source, steam or flammable gas.; Outdoor Unit; Select a location where there should be sufficient ventilation.
- 13 - ◆ Installation Location Indoor Unit 1. The inlet and outlet should not be covered so that the outflow air can reach all parts of the room. 2. Install in a location from which the condensation water can be drained out conveniently. 3. Avoid a location where there is heat source, steam or flamm...
Page 16 - Installation; Make the piping hole
- 14 - ◆ Installation Install the rear panel 1. Always mount the rear panel horizontally. Because the mouth of drainage pipe is at the left side and the left side of the rear panel is better to adjust slightly lower. 2. Fix the rear panel on the selected location with screws supplied with the unit. ...
Page 17 - Operation Procedures:
- 15 - ◆ Installation Wiring of indoor unit Note: The power of indoor unit is supplied by the outdoor. A breaker needs to be installed for safety. Operation Procedures: 1. Open the surface panel. 2. Open the cover and cover plate of electric box. (Right figure) 3. Remove the receiving window as show...
Page 19 - Open the cover of outdoor unit.
- 17 - ◆ Installation Wiring of Outdoor unit Operation Procedures: • Open the cover of outdoor unit. • The connecting wire led from the terminal board of indoor unit should be connected correctly. • The connecting wire should be a little longer so that it can easily maintained. NOTE: 1. Wiring shoul...
Page 21 - Install the connection pipe:; Align the center of the piping flare with the valve.; Exceeding tightening torque will damage the flare nut.
- 19 - ◆ Installation Install the Outdoor Unit Install the connection pipe: • Align the center of the piping flare with the valve. • Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to right figure. Note: Exceeding tightening torque will damage the flare n...
Page 22 - Connect joint of charging hose to vacuum pump.
- 20 - ◆ Installation Air Purging and Leakage Test 1. Connect charging hose of manifold value to charging end of low pressure valve (both high/low pressure valves must be tightly shut). 2. Connect joint of charging hose to vacuum pump. 3. Fully open handle of Lo manifold valve. 4. Open the vacuum pu...
Page 23 - Test Operation; Electric wiring must be connected correctly and securely; Test Operation Method; Check after Installation
- 21 - ◆ Test Operation and Check after Installation Test Operation 1. Test Operation (1) Do not switch on power before installation is finished completely. (2) Electric wiring must be connected correctly and securely (3) Cut-off valves of the connection pipes should be opened. (4) All the impuritie...
Page 24 - Electrical Schematic Diagram; Electrical Schematic Diagram (Indoor Unit); Please Help Insert Diagram in here.
- 22 - Electrical Schematic Diagram ◆ Electrical Schematic Diagram (Indoor Unit) Please Help Insert Diagram in here.
Page 25 - Electrical Schematic Diagram (Outdoor Unit)
- 23 - ◆ Electrical Schematic Diagram (Outdoor Unit) Please Help Insert Diagram in here.
Page 26 - Warranty
- 24 - Warranty Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air Conditioner (KFHHP-22-ID/KFHHP-22-OD) to be free of defects in material and workmanship for the applications specified in its operation instruction for the period of parts specified b...