Page 2 - TABLE OF CONTENTS
TABLE OF CONTENTS USE AND MAINTENANCE……………………………..…………………………………….....1-14 Precautions on Use …………………………………………………………………..……………1-3 Specifications and Technical Data…………………………………………………………………...4 Instructions of Use…………………………………………………….…………………….……….5 Description of Air Conditioner Components………………………………...
Page 3 - Use and Maintenance; Precautions on Use; Warning
- 1 - Use and Maintenance ◆ Precautions on Use Carefully read the following precautions before use Warning ★ In case of malfunction (e.g. burnt smell), cut off the power supply immediately and then contact the Authorized Service Center (626-820-1436). The malfunction continues, the air conditioner m...
Page 6 - Specifications and Technical Data; Model
- 4 - ◆ Specifications and Technical Data Model KFHHP-18-ID / KFHHP-18-OD Function Heating and Cooling Cooling capacity(BTU/hr) & (Watts) 18000 / 5300 (1400-6000) Heating capacity(BTU/hr) & (Watts) 20000 / 6000 (1100-7000) Rated voltage 208-230V ~ Rated Frequency 60Hz Cooling/Heating rated c...
Page 7 - Instructions for Use; Principle and Special Functions during Cooling Mode
- 5 - ◆ Instructions for Use Principle and Special Functions during Cooling Mode Principle: The air conditioner absorbs heat from indoor air and transmits it outdoors for discharge, hence to decrease the indoor ambient temperature. The cooling capacity decreases with the rise of outdoor ambient temp...
Page 8 - Description of Air-Conditioner Components
- 6 - ◆ Description of Air-Conditioner Components (1) Front Panel (2) Guide Louver (3) Remote Sensor (4) Wall Pipe (5) Wrapping Tape (6) Drainage hose (7) Connection pipe
Page 11 - How to Insert Batteries; Don’t mix different batteries.
- 9 - ◆ How to Insert Batteries 1. Remove the cover from the back of the remote control. 2. Insert the two batteries (Two AAA dry-cell batteries). 3. Re-attach the cover. NOTE: • Don’t mix different batteries. • Remove batteries when not in use for a longtime. • The batteries can be used for about o...
Page 13 - Cleaning and Maintenance; Check before Seasonal Use
- 11 - ◆ Cleaning and Maintenance ③ Installing the air filter Mount the air filter in the direction of the arrows. Then, clamp the cover of front panel securely. Check before Seasonal Use ① Check the air inlet/outlet on indoor and outdoor units for any blockage. ② Check the grounding cable for relia...
Page 17 - Installation Services; Precautions on Installation
- 15 - Installation Services ◆ Precautions on Installation Important Caution 1. The air-conditioning unit must be installed by professional technicians in accordance with the state and local codes. 2. Contact the local installation and service agency before installation. 3. For relocation of the air...
Page 19 - Installation Dimension Drawing
Page 21 - Install Indoor Unit; Installing the Indoor Unit; Installing Connecting Pipe
- 19 - ◆ Install Indoor Unit Notes: If the connecting cable is not long enough, please contact your distributor for a piece of special cable with sufficient length. No joints are allowed in the middle of the cable. • Be sure to connect the cable correctly. Incorrect connection will cause fault to so...
Page 22 - Vacuum – Pumping and Leakage Inspection; Draining of Condensate Water of Outdoor Unit
- 20 - ◆ Install Outdoor Unit Power Cable Connection 1. Remove the handle at the right side plate of the outdoor unit (one screw). 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and make the connection. The fitting line distributing must be c...
Page 23 - Test Run
- 21 - ◆ Install Outdoor Unit Check Items After Installation Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises Has the refrigerant gas leakage been checked? May cause unsatisfactory cooling (heating) effect Is the thermal insu...
Page 24 - Electrical Schematic Diagram; Electrical Schematic Diagram (Indoor Unit)
- 22 - Electrical Schematic Diagram ◆ Electrical Schematic Diagram (Indoor Unit)
Page 25 - Electrical Schematic Diagram (Outdoor Unit)
- 23 - ◆ Electrical Schematic Diagram (Outdoor Unit)
Page 26 - Warranty
- 24 - Warranty Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air Conditioner (KFHHP-18-ID/KFHHP-18-OD) to be free of defects in material and workmanship for the applications specified in its operation instruction for the period of parts specified b...