Page 3 - Safety instructions; WARNING; Only trained personnel should operate machinery and equipment.
2 1. Safety instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard by labeling "Caution" , "Warning" , and "Danger" . To ensure safety, be sure to observe ISO4414, ...
Page 4 - Installation
3 WARNING 1. This product is intended to be used for the general FA devices. If other applications (especially the ones indicated in 4 on page 2) are used, please contact SMC before the use. 2. Use under specified voltage and temperature. Voltage out of specification may cause malfunction, breakage,...
Page 5 - it will not only interfere the; CAUTION; Apply Ground at a resistance not exceeding 100; Wiring and piping
4 5. Do not touch electrode needle with finger or metal tool directly. It may cause injury. If electrode needle or cartridge is it may stick to the fingers, damaged by tools, it will not only interfere the specification function and performance but also may cause operation failure or accident. 6.Do ...
Page 6 - Use within operating fluid and ambient temperature range.; Keep electrode needle clean by regular maintenance.; Environment
5 9. Be sure there is no incorrect wiring before operation. Incorrect wiring may cause product breakage or malfunction. 10. Flush pneumatic piping before its installation. Make sure that all dust, water droplet, oil etc. are eliminated before piping. WARNING 1. Use within operating fluid and ambient...
Page 7 - Attached M4 threads
6 accident. 3. Do not open the case to disassemble and reconstruct the product. It may cause electric shock, operation failure and disaster such as fire. In addition, note the product, which is disassembled or reconstructed, may not satisfy the functions and performance in the specifications and is ...
Page 8 - brackets with M5 threads.; Intermediate bracket
7 3. Mount intermediate brackets on the ionizer body at regular interval. 4. Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. 5. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it wi...
Page 11 - Function description; Sensor cable
10 2. Connect the lead wires in accordance with the lead wire list. (See Chapter 4) Arrange lead wires in accordance with the wiring table. The unused wires should be cut short or covered with vinyl tape without pealing the coat to prevent them from coming contact with other wires. 3. When the feed ...
Page 12 - -2. Detection of the dirt on the electrode needle
11 3. DC mode Plasma ions or minus ions are continuously discharged. The parts other than the charged object need to be grounded to prevent them from being charged. The plasma and minus ions cannot be discharged simultaneously. 3-2. Detection of the dirt on the electrode needle When the maintenance ...
Page 13 - Selection and setting of equipment; Sensing DC mode
12 4. Selection and setting of equipment 4- 1. Sensing DC mode 1. Selection of bar length ・ Select the length applicable to work size base on static charge elimination area and static charge elimination characteristics. 2. Installation of body ・ Keep the distance between the ionizer and charged obje...
Page 15 - Charged polarity of work; Charged potential of the work
14 8. LED display POWER LED ・・・ The power supply input and the connection of the sensors are displayed. LED name Functions MAIN Lights up when the power supply is applied. (Green) (Flashes when wrong power supply is applied. ) POWER SNSR Lights up when the feed back sensor is connected.(Green) I...
Page 21 - DC mode
20 4-3 . DC mode 1. Selection of bar length ・ Select the length applicable to work size base on static charge elimination area and static charge elimination characteristics. 2. Installation of body ・ Keep the distance between the ionizer and charged objects within 50 to 2000mm. Although the ionizer ...
Page 23 - -4. Power supply cable connection circuit; NPN
22 4-4. Power supply cable connection circuit ■ NPN Note) Because the sensor monitor output ( OUT4 : Dark Green ) is not insulated from the internal circuit of the ionizer, It is grounded. (It is connected to FG).
Page 25 - Specifications; Ionizer; Electrode cartridge quantity and weight
24 5. Specifications 5-1 . Ionizer Ionizer model IZS31(NPN) IZS31P(PNP) Type Corona discharge Voltage supply method Sensing DC, pulse DC, Plus DC, Minus DC Discharge output +/- 7000 V Ion balance *1 +/-30V (For Stainless electrode needle, from -100 to +100V) Fluid Air (Clean dry air) Op. pressure (M...
Page 26 - Sensor; Sensor monitor output (When feed back sensor is used); Relation of sensor output and charge potential based pm; Charge potential V; Sensor output voltage V; Installatio
25 5-2 . Sensor Sensor model IZS31-DF (Feed back sensor) IZS31-DG (Auto-balance sensor) Operating ambient temp 0 to 50 ℃ Operating ambient humidity 35 to 80%Rh(No dew condensation) Case material ABS ABS, Stainless Vibration resistance Endurance 50Hz, Amplitude 1mm, 2hours each for XYZ Impact resista...