Page 2 - hour; 20 dB SPL - avoid or damage may occur
3 WARNING! USING THIS SYSTEM AT EXCESSIVE VOLUMES CAN CAUSE PERMANENT HEARING DAMAGE. USE AS LOW A VOLUME AS POSSIBLE. In order to use this system safely, avoid prolonged listening at excessive sound pressure lev-els. Please use the following guidelines established by the Occupational Safety Health ...
Page 3 - ENGLISH; Improved Sound Quality; Controls and Features; Using the Bodypack Features
4 ENGLISH Thank you for choosing the P4HW Hardwired Personal Monitor bodypack. The P4HW is a com-ponent of the PSM Ò 400 family of personal monitors that provides the advantages of an in-ear monitoring system, including the following: • Improved Sound Quality - high fidelity without the risk of feed...
Page 4 - Operation; BATTERY INSTALLATION; cators of the meter flicker occasionally.
5 Operation BATTERY INSTALLATION 1. Open the battery door by pushing down and sliding towards cable.2. Insert a fresh 9 V alkaline battery with the +/– terminals properly positioned (see Figure 1).3. Close the battery door. NOTE: If battery compartment door will not close, the battery is not properl...
Page 5 - READING THE LCD SCREEN; The LCD screen displays the status of each function, as follows:
6 READING THE LCD SCREEN The LCD screen displays the status of each function, as follows: 1. Input Level Meter: 3-segment input level meter displays level of incoming signal. Always check for clipping prior to inserting earphones into ears. 2. Battery Life Meter: Indicates the amount of voltage left...
Page 6 - USING THE BODYPACK FEATURES; appears to the right of the function symbol.; LOCKING THE DISPLAY; onds until the LCD returns to a numeric display.; FIGURE 2
7 USING THE BODYPACK FEATURES 1. Push either the SCROLL or SELECT button to activate the LCD screen.2. Push and hold the SCROLL button until the desired function (0/–15, MIX, EQ, or LIM) is underscored. 3. Push the SELECT button to toggle the function ON or OFF. A function is ON when a dot appears t...
Page 7 - MONO, STEREO AND MIXMODE CONTROL; Allows the performer to easily adjust the monitor mix; USING MIXMODE
8 MONO, STEREO AND MIXMODE CONTROL The bodypack provides simple configuration of a monitor mix and enables the user to customize an individual mix in a multiple mix environment. Three monitoring modes are available - mono, stereo, and MixMode. Mono: The bodypack receives one signal from the mixer an...
Page 8 - Specifications; V Alkaline battery; Certification; Reorient or relocate the receiving antenna
9 Specifications Frequency Response 20 to 20,000 Hz Total Harmonic Distortion < .1% (measured at –10 dBu out) Channel Separation 35 dB (minimum) Signal-to-noise ratio 85 dB (minimum) Maximum Output Level +5 dBu at 1% THD Maximum Input Level +7 dBu, input pad OFF +22 dBu, input pad ON Actual Input...