Page 2 - WARNING
WARNING: Danger of explosion if battery incorrectly replaced. Operate only with Shure compatible batteries. WARNING • Battery packs may explode or release toxic materials. Risk of fire or burns. Do not open, crush, modify, disassemble, heat above 140°F (60°C), or incinerate • Follow instructions fro...
Page 3 - AVERTISSEMENT
AVERTISSEMENT : Danger d'explosion si l'accu est mal placé. N'utiliser qu'avec des accus compatibles Shure. AVERTISSEMENT • Les accus risquent d'exploser ou d'émettre des matières toxiques. Risque d'incendie ou de brûlures. Ne pas ouvrir, écraser, altérer, démonter, chauffer au-dessus de 60 °C (140 ...
Page 4 - ADVERTENCIA
ADVERTENCIA: Si se sustituye la batería incorrectamente, se crea el riesgo de causar una explosión. Funciona sólo con baterías com- patibles con dispositivos Shure. ADVERTENCIA • Los conjuntos de baterías pueden estallar o soltar materiales tóxicos. Riesgo de incendio o quemaduras. No abra, triture,...
Page 5 - ATENÇÃO
ATENÇÃO: Existe perigo de explosão caso a bateria seja substituída incorretamente. Utilize apenas com baterias Shure compatíveis. ATENÇÃO • Baterias podem explodir ou liberar materiais tóxicos. Risco de incêndio ou queimaduras. Não abra, esmague, modifique, desmonte, aqueça acima de 60 °C (140 °F) o...
Page 7 - AXT920 Handheld Battery; Charging Modules; Handheld Charging Module; Included Components; Features; AXT900 Rack Mount Charging Station; Bodypack Charging Module
1 Optional Accessories 2-bay charging module for bodypack battery AXT901 AXT902 2-bay charging module for handheld battery AXT902 Batteries This charger is only for use with Shure lithium-ion rechargeable batteries, such as the AXT910, AXT920, or AXT920SL. AXT920 Handheld Battery Charging Modules Ha...
Page 8 - Controls And Connectors; Controls; SET; Automatic; Charge Status LED
2 ⑦ AC power cascade Powers additional units. ⑧ Ethernet ports (2) Connect to an Ethernet network to enable remote control and monitoring. ⑨ Network status LED (green) Off = No network link On = Network link active Flashing = Network link active, flash rate corresponds to traffic volume. ⑩ Network s...
Page 9 - Monitoring Menu; Time to Full; Network Status; Home Screen
3 ▲ ▲ SET 4 3 2 1 8 7 6 5 Monitoring Menu Use the monitoring menu to access detailed information about each battery.1. From the home screen, use the arrow keys to highlight the number of the battery you want to monitor. The white LED next to the selected battery illuminates. 2. Press the SET key to ...
Page 10 - Utility Menu; Device ID; IP Address Mode: Manual; Display Invert; Serial Number
4 Utility Menu Press and hold both arrow keys to enter and exit the utility menu, which is used to access network and display settings. hold both arrow keys Device ID This eight-character name is displayed when this device is detected on other net- work devices or in WWB software.1. Press SET key to...
Page 11 - Service; Fans; Troubleshooting; Firmware Updates
5 Recovering a Battery from Deep Discharge A deeply discharged battery is one that has been discharged to less than 3.0 volts. When the charger detects a deeply discharged battery, it automatically enters recovery mode, which charges the battery using a reduced current. The Recovery icon is displaye...
Page 12 - Specifications- AXT900 Rack Charger; Certifications; Information to the user; Networking
6 Specifications- AXT900 Rack Charger Battery Type Up to 8 rechargeable Li-Ion batteries (AXT910/920/920SL) Charge Time 50%=1 hour; 100%=3 hours Charging Module Type Up to 4 charging modules (AXT901 or AXT902) in any combination Operating Temperature Range -18°C (0°F) to 63°C (145°F) Battery Chargin...