Page 2 - Please read before operating your new Air Purifier; NOTE
Please read before operating your new Air Purifier The air purifier draws in room air from its air intake, lets the air pass through an Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collec- tion filter) inside of the unit, then discharges the air from its air outlet. The air pu...
Page 3 - ENGLISH; CONTENTS
ENGLISH E-1 ENGLISH Thank you for purchasing the SHARP Air Puri- fier. Please read this manual carefully for the correct usage information. Before using this product, be sure to read the section: “Important Safety Instructions.” After reading this manual, retain it in a conven- ient location for fut...
Page 4 - WARNING; IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following: WARNING - To reduce the risk of electrical shock, fire or injury to persons: • Read all instructions before using the unit.• Use only a 220-240 volt outlet. • Do not use the unit if the power cord...
Page 5 - CAUTIONS CONCERNING OPERATION; INSTALLATION GUIDELINES; FILTER GUIDELINES
ENGLISH E-3 CAUTIONS CONCERNING OPERATION • Do not block the intake and/or air outlet. • Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam. • Do not lay the unit down when using. • Always hold the handle on the back of the unit when mo...
Page 6 - PART NAMES
Fan Speed Indicator Lights Plasmacluster Ion ON/OFF Indicator Light POWER ON/OFF Button Plasmacluster ON/OFF Button Fan Speed Button CLEAN - SIGN Light Plasmacluster Indicator Light(blue) Odour Senser E-4 MAIN UNIT DISPLAY ILLUSTRATIVE DIAGRAM PART NAMES Main Unit Odour Sensor HEPA Filter (blue/whit...
Page 7 - INCLUDED; BACK
ENGLISH Fan Speed Indicator Lights Plasmacluster Ion ON/OFF Indicator Light POWER ON/OFF Button Plasmacluster ON/OFF Button Fan Speed Button CLEAN - SIGN Light Plasmacluster Indicator Light(blue) Odour Senser E-5 INCLUDED • Operation manual BACK Blue : Plasmacluster ON Light off : Plasmacluster OFF ...
Page 8 - PREPARATION; Remove the filters; Remove the Front Panel.; FILTER INSTALLATION; Remove the Filter Support.; Remove the Active Carbon
PREPARATION E-6 Be sure to remove the power plug from the wall outlet. To maintain the quality of the filters, they are installed in the main unit and packed in plastic bags. Be sure to remove the filters from the plastic bags before using the unit. 1 Remove the filters Remove the Front Panel. Pull ...
Page 9 - Install the filters
ENGLISH 2 Install the filters Place the HEPA Filter within the main unit with the tabs facing up. Do not install the filter backwards or the unit will not operate prop- erly. Place the Active Carbon Filter on top of the HEPA Filter. Make sure that the tab of the HEPA Filter remains visible. F i l l ...
Page 10 - OPERATION; MAIN UNIT OPERATION
OPERATION MAIN UNIT OPERATION E-8 Power ON/OFF Button • Press to start operation (short beep) and stop operation (long beep) • Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off. • Unless the power cord has been unplugged, the operations starts in the previous mode it was operat...
Page 11 - Fan Speed Button; ADJUSTMENT OF SENSOR DETECTION SENSITIVITY; With the unit OFF, press the Fan Speed Button for 3 seconds.
ENGLISH E-9 Fan Speed Button • The operation mode can be switched as below. Plasmacluster ON/OFF Button LIGHTS ON/OFF Button Switches the Plasmacluster Indicator Light and CLEAN-SIGN Light either ON or OFF. (Please press the Plasmacluster ON/OFF Button for 3 seconds.) Plasmacluster ON/OFF Indicator ...
Page 12 - CARE AND MAINTENANCE; Wipe with a dry, soft cloth; Keep the unit away from water; MAIN UNIT; ODOUR SENSOR
E-10 CARE AND MAINTENANCE To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to remain, they may become hard to clean. Wipe with a dry, soft cloth For stubborn stains or dirt, use a soft cloth dampened with warm water. Do not use volatile fluids Benzene, p...
Page 13 - CAUTION; WASHABLE ACTIVE CARBON FILTER CARE
ENGLISH 3 R i n s e t h o r o u g h l y w i t h clean water. I f r i n s i n g i n a c o n t a i n e r , b e s u r e t o r i n s e 3 t o 4 t i m e s s o that the odour is rinsed thorough- ly from the filter. WASHABLE ACTIVE CARBON FILTER CARE Care Cycle We recommend replacing the active carbon filte...
Page 14 - FILTER REPLACEMENT GUIDELINES; Depending on the usage environment, air outlet odour may become; REPLACING THE FILTERS; Replacement Filters
E-12 CARE AND MAINTENANCE FILTER REPLACEMENT GUIDELINES Depending on the usage environment, air outlet odour may become strong after several months. If dust or odour cannot be removed easily, replace the filters. (Refer to “Please read before operating your new Air Purifier”) Guide for filter replac...
Page 15 - SYMPTOM; TROUBLESHOOTING; ERROR DISPLAY; LAMP INDICATION
ENGLISH E-13 Before calling for repair, please review the list below, since the problem may not be a unit malfunction . SYMPTOM REMEDY (not a malfunction) Odours and smoke are not removed. • Clean or replace the filters if they appear to be heavily soiled. (Refer to E-11,E-12) The CLEAN-SIGN Light l...
Page 16 - SPECIFICATIONS; Standby Power
SPECIFICATIONS ModelPower supplyFan Speed AdjustmentRated PowerFan Speed Recommended Room Size Cord LengthDimensionsWeight Fan Speed Operation ~21m 2 *2 ~10m 2 *3 2.0m 410mm(W)x158mm(D)x430mm(H) 4.3kg MAX 33W 168m 3 /hour MED 12W 90m 3 /hour SILENT 3.9W(3.5W) *1 30m 3 /hour FU-W28E 220-240V 50/60Hz ...
Page 18 - Memo
Page 20 - SHARP CORPORATION
TINS-A302KKRZ Printed in China 08L OSAKA, JAPAN SHARP CORPORATION FU-W28E.eng.indd 20 08.11.13 3:45:58 PM