ENGLISH ENGLISH This manual explains the proper use of your new air conditioner. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. CONTENTS • FOR CUSTOMER ASSISTANCE (U.S.) ................................. E-2 • CONSUMER LIMI...
Page 4 - FOR CUSTOMER ASSISTANCE; TO ACCESS THE INTERNET:
E-2 FOR CUSTOMER ASSISTANCE (the United States) To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit. MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City State Zip T...
Page 5 - CONSUMER LIMITED WARRANTY; SHARP ELECTRONICS CORPORATION
ENGLISH E-3 CONSUMER LIMITED WARRANTY TO OBTAIN SUPPLY, ACCESSORY OR PRODUCT INFORMATION, CALL 1-800-BE-SHARP, OR VISIT OUR WEBSITE AT www.sharpusa.com SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 CONSUMER LIMITED WARRANTY FOR THE U.S. USERSSHARP ELECTRONICS CORPORATION w...
Page 6 - PRECAUTIONS; WARNING FOR POWER SUPPLY CORD; WARNING ABOUT GROUNDING
PRECAUTIONS Points to keep in mind when using your air conditioner.WARNINGS FOR USE • Install the air conditioner in accordance with the installation instructions in the latter section of this manual. • Do not modify any part of this product. • Do not insert anything into any part of the unit. • Ens...
Page 7 - USAGE CAUTIONS; NOTES ON OPERATION
ENGLISH E-5 USAGE CAUTIONS • Ventilate the room periodically during use, especially if using gas appliances.• Be sure to turn the unit off and disconnect the power supply cord before performing any mainte- nance or cleaning. • Do not splash or pour water directly onto the unit. Water can cause elect...
Page 8 - OPERATING CONDITIONS; MODE; ENERGY EFFICIENCY TIPS; • Avoid direct sunlight.; Keeping the filter clean greatly aids efficient operation.; • Turn off unnecessary lights.; LOCATION
MIN.12" (30cm) MIN.12" (30cm) PRECAUTIONS E-6 OPERATING CONDITIONS • The air conditioner must be operated within the temperature range indicated below. MODE Room temperature Cool 64°F ~ 95°F Dehumidification 59°F ~ 95°F • A built-in safety device may cut off operation if the temperature exce...
Page 9 - INCLUDED; SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION
ENGLISH E-7 INCLUDED CV-P12PX / CV-P13PX Exhaust hose 1 Rain deflector assembly 1 Washer 4 Window exhaust adapter 1 Window slider bracket 2 Bolt 4 Exhaust hose adapter A 1 Foam seal A 1 Nut 4 Exhaust hose adapter B 1 Foam seal B(adhesive type) 1 Split-ring washer 4 Bracket 1 Protective screen 1 Manu...
Page 10 - PART NAMES; REAR VIEW; NOTE: Actual unit might vary slightly from above illustration.; FRONT VIEW; Air filter
PART NAMES 1 Air Outlet 2 Vertical louvers 3 Horizontal louvers 4 POWER Button 5 Remote control signal receiver window 6 OPERATION Lamp (red) 7 TIMER Lamp (orange) 8 MEGA COOL Lamp (green) 9 PLASMACLUSTER Lamp (blue) 0 Air inlet REAR VIEW NOTE: Actual unit might vary slightly from above illustration...
Page 11 - REMOTE CONTROL
ENGLISH REMOTE CONTROL 1 Transmitter 2 Display 3 POWER Button 4 LIGHTS Button 5 TEMPERATURE Button 6 PLASMACLUSTER Button 7 SLEEP Button 8 MODE Button 9 ON TIMER Button 0 FAN Button q OFF TIMER Button w CANCEL Button e LOUVERS Button r RESET Button t MEGA COOL Button E-9 y MODE SYMBOLS : COOL : DEHU...
Page 12 - Install the rain deflector to the outside; Line up the holes on the rain deflector; INSTALL WINDOW PANEL; Installation in a double-hung sash window
1 Cut the foam seal A to the proper length and attach it to the window stool. 2 Attach the window exhaust adapter to the window panel inside opening. 3 Attach the protective screen to the outside of the window exhaust adapter. Use 2 screws to attach the protective screen onto the outside of the wind...
Page 13 - Cut the foam seal B to the proper length
ENGLISH If the inner width of the window is between 28" (718mm) and 36.5" (927mm) inclusive. (1) Open the window sash and place the window panel on the window stool. (2) Slide the adjustment panel to fit the window frame width. (3) Secure the window panel to the stool with 3 large wood screw...
Page 14 - Install 2 rain deflectors to the outside of
1 Cut the foam seal A to the proper length and attach it to the window stool. 2 Attach 2 window exhaust adapters to the window panel inside opening. 3 A t t a c h 2 p r o t e c t i v e s c r e e n s t o t h e outside of the window exhaust adapter. Use 4 screws to attach the protective screens onto t...
Page 16 - Line up the holes on the rain deflec; Installation in a sliding sash window
1 Cut the foam seal A to the proper length and attach it to the window frame. 2 Attach the window exhaust adapter to the window panel inside opening. 3 Attach the protective screen to the outside of the window exhaust adapter. Use 2 screws to attach the protective screen onto the outside of the wind...
Page 20 - Installation of the exhaust hose; Attach the exhaust hose adapters A; the unit, and firmly attach them to each; Attach the exhaust hose.; Unacceptable; INSTALLATION AND REMOVAL OF EXHAUST HOSE
Installation of the exhaust hose (CV-P12PX, CV-P13PX) 1 Attach the exhaust hose adapters A and B to the exhaust hose. Extend both ends of the exhaust hose and insert them into the exhaust hose adapters A and B respectively, and turn them until they stop. Make sure they are securely attached. 2 Attac...
Page 21 - Attach the exhaust hoses.; the 2 projections on the baffle into the 2
ENGLISH Installation of the exhaust hose (CV-PD13PX) 1 Attach the exhaust hose adapters A and B to the exhaust hoses. Extend both ends of the exhaust hose and insert them into the exhaust hose adapters A and B respectively, and turn them until they stop. Attach the other exhaust hose adapters A and ...
Page 22 - Attach the grille and the cover to the; Open the baffle and remove it. Insert; Install one exhaust hose.
NOTICE: If the dual-duct type unit is used as single-duct type one, please refer to the follow- ing instructions: 1 Attach the grille and the cover to the unit. Open the baffle and remove it. Insert the 2 projections on the grille into the 2 holes on the back plate of the unit, and close the grille....
Page 23 - Removal of the exhaust hose; Remove the exhaust hose adapter A.; Remove the exhaust hose adapter A; Remove the exhaust hose adapter; Lift up and remove the exhaust hose
ENGLISH Removal of the exhaust hose 1 Remove the exhaust hose adapter A. Remove the exhaust hose adapter A from the window exhaust adapter. 2 Remove the exhaust hose adapter from the unit. Lift up and remove the exhaust hose adapter from the unit by pushing down on the two projections. Projection E-...
Page 24 - LOADING BATTERIES; POWER PLUG CHECK
E-22 NOTES: • The battery should last approximately one year under normal use. • When replacing the batteries, always change both batteries at the same time, and make sure they are the same type. • If the remote control does not operate normally after replacing the batteries, press the RESET button ...
Page 25 - CAUTION; HOW TO USE THE REMOTE CONTROL
ENGLISH E-23 CAUTION • Do not expose the signal receiver window to direct sunlight. This may adversely affect its operation. If necessary, close the curtains to block out the sunlight. • Use of a fluorescent lamp in the same room may interfere with transmission of the signal. • The unit may be affec...
Page 26 - COOL MODE; Ensure that the stopcock is securely attached the; TO TURN OFF; DEHUMIDIFICATION MODE; Ensure that the stopcock is securely attached the drainpipe.; TO TURN OFF
E-24 COOL MODE Ensure that the stopcock is securely attached the drainpipe. 1 Press the MODE button to select COOL mode. COOL DEHUM FAN VENT 2 Press the POWER button to start opera- tion. • The red OPERATION lamp on the unit will light. 3 Press the TEMPERATURE button to set the desired temperature. ...
Page 27 - FAN MODE
ENGLISH E-25 FAN MODE VENTILATION MODE 2 1 3 2 1 3 In this mode, the air conditioner simply circulates the air without cooling it. In this mode, the air conditioner ventilates the air to outdoors. 1 Press the MODE button to select FAN mode. COOL DEHUM FAN VENT 2 Press the POWER button to start opera...
Page 28 - TO CHANGE AIR FLOW DIRECTION; UP / DOWN AIR FLOW DIRECTION; NOTE; Hold the vertical louver as shown in the dia-; Press the LOUVERS button on the re-; LEFT / RIGHT AIR FLOW DIRECTION; Never attempt to adjust the horizontal louvers manually.
TO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION NOTE • During VENTILATION mode, UP/DOWN air flow direction cannot be changed. Hold the vertical louver as shown in the dia- gram and adjust the air flow direction. 1 Press the LOUVERS button on the re- mote control. • The horizontal louvers w...
Page 29 - Press the PLASMACLUSTER button during; TO CANCEL; Press the PLASMACLUSTER button again.; PLASMACLUSTER OPERATION
ENGLISH E-27 1 Press the PLASMACLUSTER button during operation. • The remote control will display “ ”. • The blue PLASMACLUSTER lamp on the unit will light. TO CANCEL Press the PLASMACLUSTER button again. • The PLASMACLUSTER lamp on the unit will turn off. NOTES: • Use of the PLASMACLUSTER function ...
Page 30 - Press the MEGA COOL button during cooling; Press the MEGA COOL button again.; MEGA COOL OPERATION; prevent the room from becoming too cold.; SLEEP OPERATION; Press the SLEEP button during cooling; Press the SLEEP button.
1 Press the MEGA COOL button during cooling mode. • The remote control will display " " . • The temperature display will go off. • The green MEGA COOL lamp on the unit will light. TO CANCEL Press the MEGA COOL button again. • MEGA COOL operation is also cancelled when the mode is changed, or...
Page 31 - ON TIMER; TIMER OPERATION; OFF TIMER
ENGLISH 0.5h 1.0h 1.5h 10h 11h 12h ON TIMER 1 Press the ON TIMER button. • The time setting will change as you press the button as follows. Hold the button down to speed through the settings. • The orange TIMER lamp on the unit will light. • The time setting will count down to show the remaining tim...
Page 32 - MAIN UNIT OPERATION
Prepare for drainage and drain out water within the unit in the following cases. • When the unit stops operating and the TIMER, OPERATION and MEGA COOL lamps are blinking, the water tank is full and need to be drained. • When the unit is not used for a long time. 1 Unplug the power plug and move the...
Page 33 - CLEANING THE UNIT AND THE REMOTE CONTROL; MAINTENANCE; CLEANING THE FILTER; AIR FILTER; REMOVE THE FILTER; CLEAN THE FILTER; REINSTALL THE FILTER
ENGLISH E-31 CLEANING THE UNIT AND THE REMOTE CONTROL Wipe them with a soft, dry cloth or with a cloth moistened with a mild soap. Carefully remove any residue by wiping with a damp cloth and dry completely. Avoid splashing water onto the unit. Water can dangerously damage the electrical insulation....
Page 34 - BEFORE CALLING FOR SERVICE
BEFORE CALLING FOR SERVICE If the unit appears to be malfunctioning, check the following points before calling for a service. AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the unit plugged in or is the plug loose? • Has the fuse blown or is the circuit breaker tripped? • Did you restart the unit with...