Page 3 - WARNINGS FOR USE; CONTENTS; CAUTIONS FOR USE
1 This manual explains the proper use of your new heat pump. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. IMPORTANT SAFETY INSTRUCTIONS WARNINGS FOR USE 1 This model should be installed with a fixed power cord to the mete...
Page 4 - PART NAMES; INDOOR UNIT
2 PART NAMES INDOOR UNIT 1 Inlet (Air) 2 Open Panel 3 Air Filter 4 Air purifying fi lter 5 AUX Button 6 Receiver Window 7 Vertical airfl ow Louvre 8 Horizontal airfl ow Louvre 9 Outlet (Air) 0 PLASMACLUSTER Lamp (blue) q OPERATION Lamp (red ) w TIMER Lamp (orange ) e FULL POWER Lamp (green ) OUTDOOR...
Page 6 - USING THE REMOTE CONTROL; Cover
4 SET CURRENT CLOCK TIME There are two clock modes: 12-hour mode and 24-hour mode. Example: 5 o’clock in the afternoon Clock Display 12-hour mode PM 5:00 24-hour mode 17:00 1 To set to the 12-hour mode, press the CLOCK button once. To set to the 24-hour mode, press the CLOCK button twice. 2 Press th...
Page 7 - TIPS ON SAVING ENERGY; Below are some simple ways to save energy.; AUXILIARY MODE; Press the AUX button again.
5 T h e a i r p u r i f y i n g f i l t e r s a r e p a c k e d a s accessory of this unit. During operation, the fi lters remove dust and tobacco smoke from the air and discharges clean air. 1 Take out the air fi lters. 1 Open the open panel. 2 Push the air filters up slightly to unlock them. 3 Pul...
Page 8 - DRY or HEAT button .; HEAT; To c h a n g e t h e t e m p e r a t u r e s e t t i n g ,; DRY MODE; To change the fan speed, press the FAN; To turn off the unit, press the STOP; BASIC OPERATION
6 1 Press the COOL, DRY or HEAT button . : HEAT : COOL : DRY • The red OPERATION lamp ( ) on the unit will light. 2 To c h a n g e t h e t e m p e r a t u r e s e t t i n g , press the THERMOSTAT button. HEAT/COOL MODE • The temperature can be set within the range of 18°C to 32°C. DRY MODE • The tem...
Page 9 - HORIZONTAL AIR FLOW DIRECTION; • The horizontal airfl ow louvres will swing.; Press the SWING button(; • The adjusted position will be memorized and will; VERTICAL AIR FLOW DIRECTION; • The vertical airfl ow louvre will swing.; ADJUSTING THE AIR FLOW DIRECTION
7 HORIZONTAL AIR FLOW DIRECTION 1 Press the SWING button( ). • The horizontal airfl ow louvres will swing. 2 Press the SWING button( ) again when the horizontal airfl ow louvres are at the desired position. NOTE: • The adjusted position will be memorized and will be automatically set to the same pos...
Page 10 - SPOT AIR; Press the SPOT AIR button to select; In cool or dry mode, the vertical airfl ow louvre; During operation, press the COANDA; TO CANCEL; Press the COANDA AIRFLOW button again.; COANDA AIRFLOW
8 SPOT AIR The louvres are adjusted so that air fl ow is delivered to the desired area. 1 Press the SPOT AIR button to select the desired air fl ow direction. NOTE: • If you want the SPOT AIR setting in the FULL P O W E R m o d e , p r e s s t h e S P O T A I R b u t t o n during the FULL POWER oper...
Page 11 - D u r i n g o p e r a t i o n , p r e s s t h e F U L L; Press the FULL POWER button again.; FULL POWER OPERATION; During operation, press the ENERGY; Press the ENERGY SAVE button again.
9 The unit works at the maximum power and op-timum louvre direction to quickly cool or warm the room. 1 D u r i n g o p e r a t i o n , p r e s s t h e F U L L POWER button. • The remote control will display “ ” and AIR FLOW symbol will get longer. • The temperature display will go off. • The green ...
Page 12 - set the desired time.; TIMER OPERATION; TIMER OFF; TIPS ABOUT TIMER OFF OPERATION
10 1.2.3.5h OFF TIMER When the 1.2.3.5h OFF TIMER is set, the unit will automatically turn off after the set time (hours). 1 Press the 1.2.3.5h OFF TIMER button to set the desired time. • The time setting will change as you press the button as follows. • The orange TIMER lamp ( ) on the unit will li...
Page 13 - Cancel the TIMER setting fi rst, then set it again
11 TIMER ON 1 Press the TIMER ON ( ) button. 2 T h e T I M E R O N i n d i c a t o r w i l l b l i n k ; press the TIME ADVANCE or REVERSE button to set the desired time. (The time can be set in 10-minute increments.) 3 Press the TIMER SET (SET/C) button. • The orange TIMER lamp ( ) on the unit will...
Page 14 - PLASMACLUSTER OPERATION; During operation, press the; Press the PLASMACLUSTER button again.; SELF CLEAN OPERATION; Press the SELF CLEAN button when; Press the SELF CLEAN button.
12 PLASMACLUSTER OPERATION Plasmacluster ions released into the room will reduce some airborne mold and viruses. 1 During operation, press the PLASMACLUSTER button. • The remote control will display “ ”. • The blue PLASMACLUSTER lamp on the unit will light up. TO CANCEL Press the PLASMACLUSTER butto...
Page 15 - OPERATING TEMPERATURE RANGE; VACANCY OPERATION; Press the HEAT button.; Press the VACANCY button again.; WHEN POWER FAILURE OCCURS
13 ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE VACANCY OPERATION Heating operation with 10°C set temperature will be performed to protect your home and furniture from frost damage, even when you are out. 1 Press the HEAT button. 2 Press the VACANCY button. • The remote control will dis...
Page 16 - MAINTENANCE
14 MAINTENANCE AFTER HEAT PUMP SEASON 1 Operate the unit in the SELF CLEAN operation to allow the mechanism to thoroughly dry. 2 Stop the operation and turn off the circuit breaker. 3 Clean the fi lters, then reinstall them. MAINTENANCE BEFORE HEAT PUMP SEASON 1 Make sure that the air fi lters are n...
Page 17 - BEFORE CALLING FOR SERVICE
15 The following conditions do not denote equip-ment malfunctions UNIT DOES NOT OPERATE T h e u n i t w i l l n o t o p e r a t e i f i t i s t u r n e d o n immediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the unit. Wait 3 minut...