Page 2 - IMPORTANT SERVICE SAFETY PRECAUTION; X-RADIATION AND HIGH VOLTAGE LIMITS
2 19R-M10019R-M100S IMPORTANT SERVICE SAFETY PRECAUTION Ë Service work should be performed only by qualified service technicians who are thoroughlyfamiliar with all safety checks and the servicing guidelines which follow: 4A 125V SERVICING OF HIGH VOLTAGE SYSTEMAND PICTURE TUBE When servicing the hi...
Page 3 - SAFETY NOTICE; BEFORE RETURNING THE RECEIVER
3 19R-M10019R-M100S 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212 1234567890123456789012345678901212345678901234567890123456789012123456789012345678...
Page 4 - LOCATION OF USER'S CONTROL; Basic Remote Control Functions
4 19R-M10019R-M100S LOCATION OF USER'S CONTROL TV CH – VOL + POWER VIDEO IN AUDIO CH – VOL + POWER MENU MENU Infrared Transmitter Window INPUTPress → Switch to external video input mode.Press again → Switch to TV mode. CHANNEL UP/DOWN( ) Selects next higher channel.( ) Selects next lower channel. • ...
Page 5 - INSTALLATION AND SERVICE INSTRUCTIONS; screwdrivers or TV alignment tools.
5 19R-M10019R-M100S CIRCUIT PROTECTION The receiver is protected by a 4.0A fuse (F701),mounted on PWB-A, wired into one side of the ACline input. X-RADIATION PROTECTOR CIRCUIT TEST After service has been performed on the horizontaldeflection system, high voltage system, B+ system,test the X-Radiatio...
Page 6 - FIX VALUE as show in Figure A.
6 19R-M10019R-M100S For adjustments of this model, the bus data is converted to various analog signals by the D/A converter circuit. Note: There are still a few analog adjustments in this series such as focus and master screen voltage. Follow the steps below whenever the service adjusment is require...
Page 9 - Figure B: WAVEFORM FOR SCREEN ADJUSTMENT; SERVICE ADJUSTMENT; RF AGC Adjustment; select another channel.; Screen Adjustment
9 19R-M10019R-M100S White Balance Adjustment 1. Receive a good local channel.2. Select the service adjustment "S12" and set the data value to "00" to set the color level to the minimun.You may skip this step, if you selected a B/W pictureor monoscope. 3. Alternately adjust the servic...
Page 10 - Horizontal Position Adjustment
10 19R-M10019R-M100S Vertical-Size, V-Linearity andV-S Correction Adjustments 1. Receive a good local channel.2. Enter the service mode DEF category and select the adjustment "D02" for Vertical Size, "D05" for V-Linearity and "D06" for V-S Correction Adjustment. 3. Set in ord...
Page 11 - CHASSIS LAYOUT
11 19R-M10019R-M100S 6 5 4 3 2 1 A B C D E F G H CHASSIS LAYOUT Ë 19R-M100 Ë 19R-M100S
Page 12 - BLOCK DIAGRAM
12 19R-M10019R-M100S 6 5 4 3 2 1 A B C D E F G H BLOCK DIAGRAM
Page 13 - DESCRIPTION OF SCHEMATIC DIAGRAM; WAVEFORMS
13 19R-M10019R-M100S DESCRIPTION OF SCHEMATIC DIAGRAM NOTES:1. The unit of resistance "ohm" is omitted. (K=k Ω =1000 Ω , M=M Ω ) 2. All resistors are 1/10 watt, unless otherwise noted.3. All capacitors are µF, unless otherwise noted. (P=pF=µµF) 4. (G) indicates ±2% tolerance may be used.5. i...
Page 14 - MODEL 19R-M100 SCHEMATIC DIAGRAM: MAIN Unit
15 19R-M10019R-M100S 14 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H COMBINATION IC201 RH-iX3354CEZZ RH-iX3354CEN1 C211 VCKYCY1HB102K(1000p) C301 VCCCCY1HH470J(47p) VCCCCY1HH220J(22p) C304 VCCCCY1HH470J(47p) VCCCCY1HH220J(22p) C802 VCEA0A1CW106M(10 (16V)) R209 VRS-CY1JF123J(12k) VRS-CY1JF000J(0) R302 ...
Page 15 - MODELS 19R-M100S SCHEMATIC DIAGRAM: MAIN Unit
17 19R-M10019R-M100S 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H COMBINATION IC201 RH-iX3354CEZZ RH-iX3354CEN1 C211 VCKYCY1HB102K(1000p) C301 VCCCCY1HH470J(47p) VCCCCY1HH220J(22p) C304 VCCCCY1HH470J(47p) VCCCCY1HH220J(22p) C802 VCEA0A1CW106M(10 (16V)) R209 VRS-CY1JF123J(12k) VRS-CY1JF000J(0) R302 ...
Page 16 - MODEL 19R-M100 SCHEMATIC DIAGRAM: CRT Unit
18 19R-M10019R-M100S 6 5 4 3 2 1 A B C D E F G H MODEL 19R-M100 SCHEMATIC DIAGRAM: CRT Unit
Page 17 - MODEL 19R-M100S SCHEMATIC DIAGRAM: CRT Unit
19 19R-M10019R-M100S 6 5 4 3 2 1 A B C D E F G H MODEL 19R-M100S SCHEMATIC DIAGRAM: CRT Unit
Page 18 - PRINTED WIRING BOARD ASSEMBLIES
20 19R-M10019R-M100S 6 5 4 3 2 1 A B C D E F G H PWB-A: MAIN Unit (Wiring Side) PRINTED WIRING BOARD ASSEMBLIES
Page 21 - PICTURE TUBE; PARTS LIST; PARTS REPLACEMENT; MAIN UNIT; TUNER
Ref. No. Part No. ★ Description Code Ref. No. Part No. ★ Description Code 23 19R-M10019R-M100S PICTURE TUBE PARTS LIST PARTS REPLACEMENT Replacement parts which have these special safety characteristicsidentified in this manual; electrical components having such featuresare identified by å and shade...
Page 23 - RESISTORS
Ref. No. Part No. ★ Description Code Ref. No. Part No. ★ Description Code 25 19R-M10019R-M100S C304 VCCCCY1HH470J J 47p 50V Ceramic AA (IC201:iX3354CEZZ) C304 VCCCCY1HH220J J 22p 50V Ceramic AA (IC201:iX3354CEN1) C305 VCKYCY1HB103K J 0.01 50V Ceramic AA C306 VCQYTA1HM103K J 0.01 50V Mylar AB C354 VC...
Page 25 - SWITCHES
Ref. No. Part No. ★ Description Code Ref. No. Part No. ★ Description Code 27 19R-M10019R-M100S R2044 VRS-CY1JF683J J 68k 1/16W M-Ox. AA R2045 VRS-CY1JF101J J 100 1/16W M-Ox. AA R2047 VRS-CY1JF221J J 220 1/16W M-Ox. AA R2048 VRS-CY1JF562J J 5.6k 1/16W M-Ox. AA R2049 VRS-CY1JF333J J 33k 1/16W M-Ox. AA...
Page 26 - CABINET PARTS; CRT UNIT
Ref. No. Part No. ★ Description Code Ref. No. Part No. ★ Description Code 28 19R-M10019R-M100S 1 CCABA0108WEH3 X Front Cabinet Ass’y AY 1-1 Not Available – Front Cabinet — 1-2 GCOVA0003GJSA X Cover for R/C AG 1-3 HBDGB1001GJSB X Badge, "SHARP" AF 1-4 JBTN-0003GJSA X Button(Power, Vol-up/down...
Page 27 - PACKING OF THE SET
Ref. No. Part No. ★ Description Code Ref. No. Part No. ★ Description Code 29 19R-M10019R-M100S PACKING OF THE SET REAR Use tape tofix the top side ofpacking case. ★ Packing Case FRONT ★ Buffer Material ★ Wrapping Paper ★ Polyethylene Bag Operation ManualInfrared R/C Unit ★ Batteries ★ MARK : Not rep...
Page 28 - COPYRIGHT © 2001 BY SHARP CORPORATION
Ref. No. Part No. ★ Description Code Ref. No. Part No. ★ Description Code 30 19R-M10019R-M100S COPYRIGHT © 2001 BY SHARP CORPORATION ALL RIGHTS RESERVED. No part of this publication may be reproduced,stored in a retrieval system, or transmitted inany form or by any means, electronic, mechanical,phot...