Page 2 - OEM burners shipped with combustion head mounted.
TABLE OF CONTENTS TECHNICAL DATA.............................................................................................................. 1 Dimensions............................................................................................................ 1 Specifications.......................
Page 3 - TECHNICAL DATA; DIMENSIONS; ABSORBED ELECTRICAL POWER:
RIELLO 40 F10 TECHNICAL DATA D6012 DIMENSIONS MODEL F10 A „ , Q D -.F: Inches 10 5/16 12 8 1/32 3 15/16 5 10 7/16 mm 262 305 204 100 127 265 E1: 10 inch long (254 mm) tubes also available. SPECIFICATIONS FUEL: No. 2 Fuel Oil FIRING RATE: 1.45 to 2.95 GPH 4.7 to 9.5 kg/h EFFECTIVE OUTPUT: 203,000 to ...
Page 4 - F10 BURNER COMPONENTS
OIL BURNER COMPONENTS IDENTIFICATION RIELLO 40 SERIES F10 BURNER COMPONENTS 1. Lockout indicator lamp and 9. End cone Reset button 10. Turbulator adjustment screw 2. Primary control 11. Air tube cover 3. Primary control sub-base 12. Coil 4. Pump pressure regulator 13. Vacuum gauge connection port ad...
Page 5 - METHOD 1 - UNIVERSAL MOUNTING FLANGE
ASSEMBLY OF AIR TUBE TO BURNER CHASSIS The air tube and drawer assembly are shipped in a carton separate from the burner chassis. Choose the proper air tube length to obtain the tube insertion for the specific installation. A) Remove the AIR TUBE and BURNER CHASSIS from their respective cartons. B) ...
Page 6 - H B; COMBUSTION
B) Position the MOUNTING GASKET (3) between the flat surface of the UNIVERSAL MOUNTING FLANGE (10) and the appliance. Line up the holes in the UNIVERSAL MOUNTING FLANGE with the STUDS (4) on the appliance mounting plate and securely bolt the UNIVERSAL MOUNTING FLANGE to the plate. DRY BASE BOILER H ...
Page 7 - METHOD 3 - PEDESTAL MOUNT; ELECTRICAL CONNECTIONS
METHOD 2 - SEMI-FLANGE COLLAR A) Follow item C from METHOD 1. B) Align the air tube and attached adjustable collar so air tube is centered in the burner access hole of the boiler/furnace unit. Mark the center of the two holes in the ADJUSTABLE COLLAR on to the front plate of the heating unit. Then d...
Page 8 - OR; a LOW VOLTAGE control (24V AC 60 cycle) using a R8038A; made, or failure of the pump shaft seal may occur.; APPLICATION FIELD WIRING; FACTORY; REMOTE SENSING OF SAFETY LOCKOUT:; The SAFETY SWITCH in the 530SE; BOX on the burner will be damaged should lockout occur.
The burner may be controlied using either a DIRECT LINE VOLTAGE control circuit (120V AC 60 cycle) OR a LOW VOLTAGE control (24V AC 60 cycle) using a R8038A Honeywell switching relay or equivalent. Using the appropriate diagram below, make electrical connections to burner. All wiring must be done in...
Page 13 - PUMP PURGE; will result in
PUMP PURGE NOTE: to protect the pump gears, it is advisable to lubricate the pump prior to purging a lift system. Apply oil through the VACUUM PORT (C). A) SINGLE LINE (GRAVITY FEED SYSTEM) A) Loosen the bleeder valve (A) until oil flows out. Tighten the bleeder valve securely and start burner. B) W...
Page 14 - SETTING THE AIR ADJUSTMENT PLATE
SETTING THE AIR ADJUSTMENT PLATE A) Regulation of the combustion air flow is made by adjustment of the manual AIR ADJUSTMENT PLATE (1) after loosening the FIXING SCREWS (2 & 3). The initial setting of the air adjustment plate should be made according to Column 5 in the Burner Set-up Chart. B) Th...
Page 16 - SPARE PARTS
Page 17 - SPARE PARTS LIST
SPARE PARTS LIST TI 0 1 cn NO. CODE DESCRIPTION NO. CODE DESCRIPTION 1 3007234 Burner Back Cover 33 3007205 Manual Air Shutter 2 3006992 Pipe connector - Supply 34 3007209 Air Intake Housing 3 3006571 3/8” NPT/Metric Adapter - Male 4 3006993 Pipe connector - Return 40 3949071 Short Combustion Head 5...
Page 18 - Follow the instructions furnished with the heating appliance.
FOR CANADA PRECAUTIONS AIR FOR COMBUSTION Do not install burner in room with insufficient air for combustion. Be sure there is an adequate air supply for combustion if the boiler/furnace room is enclosed. It may be necessary to create a window to permit sufficient air to enter the boiler/furnace roo...
Page 19 - throughly cleaned prior to installing a new filter cartridge.
FOR USA PRECAUTIONS AIR FOR COMBUSTION Do not install burner in room with insufficient air for combustion. Be sure there is an adequate air supply for combustion if the boiler/furnace room is enclosed. An opening of at least twice the area of the flue should be available, or one square foot of area ...
Page 20 - Mississauga, Ontario L5N 6H6; RIello Corporation of America; 5 Pond Park Road
RIello Canada Inc. 2165 Meadowpine Boulevard Mississauga, Ontario L5N 6H6 Telephone : 905-542-0303 Facsimile : 905-542-1525 Toll Free : 1-800-387-3898 RIello Corporation of America 35 Pond Park Road Hingham, Massachusetts 02043 Telephone : 781-749-8292 Facsimile : 781-740-2069 Toll Free : (outside M...