Page 2 - TABLE OF CONTENTS; MAINTENANCE AGREEMENT; Read and observe the safety rules.; HORSE POWER; FULL ONE YEAR WARRANTY ON SEARS GENERATORS
2 — ENG D20508 TABLE OF CONTENTS MAINTENANCE AGREEMENT The Sears Warranty, plus a Maintenance Agreement, pro-vide maximum value for your Sears products. Contactyour nearest Sears store for details. CUSTOMER RESPONSIBILITIES Read and observe the safety rules. Follow a regular schedule in maintaining,...
Page 3 - SAFETY GUIDELINES - DEFINITIONS; RISK OF ELECTROCUTION AND FIRE; When using this product basic precautions should always be; • SAVE THESE INSTRUCTIONS •; IMPORTANT SAFETY INSTRUCTIONS; HAZARD
3 — ENG D20508 CAUTION indicates a potentially hazardous situationwhich, if not avoided, may result in minor or moderateinjury. This manual contains information that is important for you to know and understand. This information relates toprotecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To h...
Page 4 - READ AND UNDERSTAND ALL WARNINGS BEFORE
4 — ENG D20508 READ AND UNDERSTAND ALL WARNINGS BEFORE ATTEMPTING TO OPERATE GENERATOR. Use of worn damaged, undersizedor ungrounded extension cords. Placing generator on or againsthighly conductive surface, such asa steel walkway or metal roof. Improper connection of items togenerator. Operation of...
Page 5 - RISK OF FIRE; Improper storage of fuel
5 — ENG D20508 RISK OF FIRE Turn engine off and allow it to coolbefore adding fuel to the tank. Equiparea of operation with a fire extin-guisher certified to handle gasolineor fuel fires. Add fuel to tank in well ventilateda r e a . M a k e s u r e t h e r e a r e n osources of ignition near the gen...
Page 6 - RISK OF BREATHING - INHALATION HAZARD; H A Z A R D; HOW TO PREVENT IT; Risk of Injury and Property Damage When
6 — ENG D20508 READ AND UNDERSTAND ALL WARNINGS BEFORE ATTEMPTING TO OPERATE GENERATOR. RISK OF BREATHING - INHALATION HAZARD Operate generator in clean, dry, wellventilated area. Never operate unitin enclosed areas such as garages,basements, storage, sheds, or inany location occupied by humans oran...
Page 7 - RISK OF UNSAFE OPERATION
7 — ENG D20508 READ AND UNDERSTAND ALL WARNINGS BEFORE ATTEMPTING TO OPERATE GENERATOR. • Review and understand all ofthe operating instructions andwarnings in this manual. • Become familiar with theoperation and controls of thegenerator. Know how to shut itoff quickly. • Equip area of operation wit...
Page 8 - RISK FROM LIFTING; Lifting a very heavy object.; RISK OF MOVING PARTS
8 — ENG D20508 RISK FROM LIFTING HAZARD HOW TO PREVENT IT WHAT COULD HAPPEN The generator is too heavy to belifted by one person. Obtain assis-tance from others before you try tomove it. Serious injury can result from attempt-ing to lift too heavy an object. Lifting a very heavy object. READ AND UND...
Page 9 - REMOVE GENERATOR FROM CARTON; ASSEMBLY; TOOLS NEEDED FOR ASSEMBLY
9 — ENG D20508 Read owner’s manual. Do not attempt to operate equipment until you have read Owner’sManual for Safety, Assembly, Operation, Maintenance, Storage Instructions. REMOVE GENERATOR FROM CARTON • Open carton from top. • Cut carton along dotted lines. • Remove all carton inserts. • Remove ge...
Page 10 - Grounding Lug; Repeat the above steps for the opposite side.
10 — ENG D20508 INSTALLING WHEEL KIT The Sears Wheel Kit was designed to greatly improvethe portability of your generator. GROUNDING THE GENERATOR A grounding lug is supplied with the generator for usewhen required by local electrical ordinances. Refer toarticle 250 of the National Electrical Code t...
Page 11 - OPERATION; RECEPTACLES; Compare this illustra-; CHOKE SWITCH- Lever used to start cold engine.; KNOW YOUR GENERATOR
11 — ENG D20508 OPERATION ENGINE OIL FILL CHOKE SWITCH ENGINE RUN/STOP SWITCH AIR CLEANER FUEL TANK 120 VOLT RECEPTACLES CIRCUIT BREAKERS 240 VOLT RECEPTACLE FUEL CAP RECEPTACLES Your generator is equipped with duplex 120 voltreceptacles and a twistlock 240 volt receptacle. The unit is also equipped...
Page 12 - Extension Cord; Application Guide; LOW OIL SHUTDOWN; The Low Oil Shutdown mechanism is very sen-; GENERATOR CAPACITY
12 — ENG D20508 OBTAINING ELECTRICITY FROMGENERATOR There are basically two ways to obtain electricity forma generator: • Use of extension cords directly from the genera-tor to the appliance, lights, tools, etc. • Use of a double-throw transfer switch installeddirectly to the main electrical supply ...
Page 13 - Gasoline; BEFORE STARTING ENGINE; Adding Engine Oil; Do not fill above this point.; When adding oil to the engine crankcase, use a; Never fill fuel tank indoors.; To Start Your Generator
13 — ENG D20508 Connecting Generator To Main ElectricalSupply Potential hazards exist when a electrical generator isconnected to the main electrical supply coming intothe house. It is at that point that the generator couldfeed back into the utility company’s system causingpossible electrocution of w...
Page 14 - MAINTENANCE; in extreme dusty or dirty conditions.; CUSTOMER RESPONSIBILITIES TABLE; MAINTENANCE TASK; See Note 2; STOPPING ENGINE; Disconnect all electrical loads.; CONNECTING ELECTRICAL LOADS; Connect the lights next.
14 — ENG D20508 MAINTENANCE ON STOP Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter, more often if operated in extreme dusty or dirty conditions. Note 2: Check oil after 5 hours of operation (See the Oil paragraph on page 15 of this section) CUSTOMER RE...
Page 15 - Oil; Change the oil as follows:; Service Air Cleaner; To service air cleaner follow these steps:; Remove cartridge from cover.; BASE
15 — ENG D20508 GENERAL RECOMMENDATIONS The warranty of the generator does not cover itemsthat have been subjected to operator abuse or negli-gence. To receive full value from the warranty, opera-tor must maintain the generator as instructed in thismanual. Some adjustments will need to be made perio...
Page 16 - DO NOT; Clean and Replace Spark Plug; Check spark plug yearly or every 100 operating hours.; SERVICE ADJUSTMENTS; CLEAN
16 — ENG D20508 CARBURETOR The carburetor of your generator is pre-set at the fac-tory. The carburetor should not be tampered with. If yourgenerator is used at an altitude in excess of 4000 feetperformance may be affected. If so consult with yournearest Sears Service Center regarding high altitude s...
Page 17 - STORAGE; PROBLEM; Engine will not start; TROUBLESHOOTING GUIDE; Engine Preparation
17 — ENG D20508 STORAGE PROBLEM CAUSE CORRECTION Engine will not start No electrical output Repeated circuit breaker trip-ping Generator overheating thecircuit breaker depressed 1. Low on fuel or oil. 2. Ignition switch in "Off" position. 3. Faulty spark plug. 4. Choke in wrong position. 5. ...
Page 20 - NOTES
Page 23 - Para pedir servicio de reparación a; HomeCentral; Au Canada pour service en français:; Anytime, day or night
Para pedir servicio de reparación a domicilio, y para ordenar piezas: 1-888-SU-HOGAR SM (1-888-784-6427) HomeCentral ® Au Canada pour service en français: 1-800-LE-FOYER MC (1-800-533-6937) www.sears.ca To purchase or inquire about a Sears Service Agreement or Sears Maintenance Agreement: 1-800-827-...
Page 25 - TABLA DE CONTENIDOS; ACUERDO DE MANTENIMIENTO; CABALLAJE; GARANTÍA LIMITADA DE UN AÑO PARA SEARS; Tienda donde se compró:
2 — SP D20508 TABLA DE CONTENIDOS ACUERDO DE MANTENIMIENTO La Garantía de Sears más el Contrato de Mantenimiento ledan el valor máximo a los productos de Sears. Para mayorinformación, contactarse con la tienda Sears más cercana. RESPONSABILIDADES DEL CLIENTE Leer y observar las reglas de seguridad.S...
Page 26 - DEFINICIONES DE NORMAS DE SEGURIDAD; PELIGRO; ADVERTENCIA; PRECAUCION; RIESGO; RIESGO DE INCENDIO Y ELECTROCUCIÓN; Siempre que se use este producto se deben seguir precauciones; • CONSERVAR ESTAS INSTRUCCIONES •; INSTRUCCIONES IMPORTANTES DE SEGURIDAD
3 — SP D20508 DEFINICIONES DE NORMAS DE SEGURIDAD PRECAUCION indica una situación potencialmente peligrosa, lacual, si no es evitada, podría resultar en lesiones menores. Este manual contiene información que es importante que usted conozca y comprenda. Dicha información se relaciona con laprotección...
Page 31 - RIESGO DE PIEZAS MOVIBLES; RIESGO AL LEVANTAR
8 — SP D20508 RIESGO ¿QUÉ PUEDE SUCEDER? ¿CÓMO EVITARLO? El contacto con piezas moviblespuede resultar en lesiones serias. El generador tiene piezas que giran a altavelocidad durante su operación. Estaspiezas están cubiertas por panelesprotectores para evitar lesiones. Nunca operar el generador sin ...
Page 32 - DESEMBALAJE DEL GENERADOR; ENSAMBLAJE; CONTENIDO DE LA CAJA
9 — SP D20508 Leer el manual del operador. No intentar operar en este equipo hasta haber leído lasinstrucciones de seguridad, ensamblaje operación, mantenimiento y almacenaje en el manualdel operador. DESEMBALAJE DEL GENERADOR • Abrir la caja por la parte superior. • Cortar la caja en la línea punta...
Page 33 - CONEXIÓN DEL GENERADOR A TIERRA; INSTALACIÓN DE LAS RUEDAS
10 — SP D20508 CONEXIÓN DEL GENERADOR A TIERRA Junto al generador se suministra una conexión de lengüetap a r a s e r u s a d a c u a n d o s e r e q u i e r e c u m p l i r c o n l a sregulaciones eléctricas locales. Refiérase al artículo 250 delCódigo eléctrico nacional si fuera preciso aclarar al...
Page 34 - OPERACIÓN; FAMILIARIZARSE CON EL GENERADOR
11 — SP D20508 OPERACIÓN FAMILIARIZARSE CON EL GENERADOR Leer este Manual de Operación y las pautas de seguridad antes de cooperar en regenerador. Compararesta ilustración con su generador para familiarizarse con la ubicación de los diversos controles y regulaciones oajustes. Conservar este manual p...
Page 35 - Cordones de extensión; CAPACIDAD DEL GENERADOR; Guía de Aplicaciones; DeVilbiss Air Power Company, Jackson, TN 38301
12 — SP D20508 TOMA DE ELECTRICIDAD DELGENERADOR Existen básicamente dos formas para tomar electricidad deun generador: • Mediante cordones de extensión enchufadosdirectamente entre el generador y el artefacto, lámparade luz, herramienta, etc. • Conectando la salida del generador a la fuente desumin...
Page 36 - ANTES DE ARRANCAR EL MOTOR; Relleno de aceite al motor; Gasolina; PARA ARRANCAR EL MOTOR
13 — SP D20508 Conexión del Generador al SuministroEléctrico Principal Cuando se conecta el generador al punto del suministro prin-cipal de la casa que viene de la empresa de servicios eléctricos,existe el peligro potencial de que la electricidad del generadorse vaya hacia afuera por la línea de sum...
Page 37 - MANTENIMIENTO; CARTILLA DE RESPONSABILIDADES DEL CLIENTE; TAREA DE MANTENIMIENTO; Ver Nota 2; antes de arrancar el generador.; PARANDO EL MOTOR
14 — SP D20508 MANTENIMIENTO Nota 1: Cambiar el aceite después de las primeras 2 horas y después cada 50 horas de operación, o más frecuentemente si funciona en condiciones extremadamente polvorientas o sucias. Nota 2: Revisar el aceite después de cada 5 horas de operación (Ver el párrafo referente ...
Page 38 - Mantenimiento del Filtro de Aire; RECOMENDACIONES GENERALES; Aceite; Cambiar el Aceite como Sigue:
15 — SP D20508 • Reinstalar el tapón de drenaje. Cerciorarse que quedefirmemente ajustado. • Llenar el cárter con aceite nuevo del tipo apropiado (verla sección Relleno de Aceite al Motor) hasta la marca"FULL" (Lleno) en la varilla medidora. Siempre revisar elnivel de aceite con la varilla a...
Page 39 - REGULACIONES O AJUSTES DE SERVICIO; Limpieza del Protector/Mofle; LIMPIEZA Y CAMBIO DE BUJÍA; Limpiar la zona alrededor de la bujía.
16 — SP D20508 CARBURADOR El carburador está precalibrado de fábrica y no debe alterarse.El funcionamiento del generador puede afectarse si opera amás de 1220m/4000 pies sobre el nivel del mar. De ser así,consultar al Centro de Servicio Sears más cercano sobre loscambios necesarios para operar a esa...
Page 40 - GUÍA PARA DIAGNÓSTICO DE PROBLEMAS; INSTRUCCIONES PARA ALMACENAJE; Preparación del motor
17 — SP D20508 PROBLEMA CAUSA CORRECCIÓN GUÍA PARA DIAGNÓSTICO DE PROBLEMAS El motor no arranca No genera electricidad. El interruptor de circuito saltarepetidamente. El generador se recalienta 1. Poco combustible o aceite. 2. Interruptor de encendido en “Off” (Apagado). 3. Bujía defectuosa. 4. Acel...
Page 42 - GARANTÍA DEL SISTEMA DE CONTROL DE EMISIONES; LAS PIEZAS RELACIONADAS CON LAS EMISIONES INCLUYEN:
28 — SP D20508 GARANTÍA DEL SISTEMA DE CONTROL DE EMISIONES Garantía del Sistema de Control de Emisiones (Garantía SCE) para motores instalados en equipos utilitarios y para jardín a partirde 1995 en California (y a partir de 1997 en otros Estados): A. APLICABILIDAD: Esta garantía se aplica a los mo...
Page 43 - NOTA