Page 2 - Thank you for purchasing your new Schweigen exhaust fan system.
Page 2 1. Welcome Thank you for purchasing your new Schweigen exhaust fan system. To get the maximum output from this unit, please read through this operating guide before use and installation. The operating guide contains important information on the correct use and maintenance of the unit, as well...
Page 3 - Table of Contents
Page 3 Table of Contents 1. Welcome _____________________________________________________________________________________ 2 2. Your Safety Before Installation ______________________________________________________________________________ 4 Electrical Cord ____________________________________________...
Page 4 - Before Installation; Electrical Cord; MUST; DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.
Page 4 2. Your Safety 1. This appliance is not intended for use by person/s (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision or instruction concerning the use of the appliance by a person ...
Page 5 - Motor Features; WARRANTY 5 YEARS; General Notes on Installation and Use; Excessive bends in the ducting will compromised extraction.; Recommended Installation Distance; recommended 4 metres
Page 5 2. Your Safety This manual is for the installation of the motor systems use for bathroom and general extraction. Motor Features • Universal mounting all position with IP23 degree of weather protection• Patented anti water intrusion system.• Acoustic dome with super quiet, long vane centrifuga...
Page 6 - Safety of Children
Page 6 2. Your Safety Minimum Mounting Height This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above floor/ground level. Avoidance of Back Flow Care should be taken to avoid the back flow of gases into the room. Safety of Child...
Page 7 - Not included in the box:
Page 7 BR550, BRW650, BRB750 Included in the box: 1. Motor system (350W x 295H mm approx.) Approx. 3 metre, 10amp cable and standard plug (backdraft shutter and weather shield included) 2. Fire resistant 200mm metal pipe 3. Flexible ducting. Approx. 4 metres, 200mm (210mm outside dimension) diameter...
Page 8 - Roof Installation; protrudes at least 80mm
Page 8 4. Installation 1. Roof Installation Recommended duct length: 4 metres. Mount 200mm metal pipe securely to beams, trusses or other appropriate structures: refer figure 1. The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other appropriate sealing ...
Page 9 - IMPORTANT
Page 9 Figure 1 Roof installation Fix fan module using side locking screw Connect to bathroom vent Connect to power supply NOTE: Prevent any cord bunching by pulling cord through from plug top end NOTE: Recommended ducting length 4 metres. Fully extend ducting, cut to length. Fit side supports to lo...
Page 13 - Flexible Ducting
Page 13 5. Flexible Ducting Flexible Ducting Flexible ducting must be fully extended and cut to the required length upon installation. Maximum fan performance will not be achieved unless the ducting is fully extended. Failure to fully extend the ducting results in smaller air passage and lower airfl...
Page 14 - Shallow Roof Space
Page 14 5. Flexible Ducting Figure 6 Shallow roof space 90 degree curve PVC or galvanise curve Shallow Roof Space In shallow roof spaces, do not crush or kink flexible ducting, as it will reduce air flow severely. 90 degree curve made of PVC or galvanise can be used as a substitute for the bend, ref...
Page 15 - Securing Flexible Duct; Option 1
Page 15 5. Flexible Ducting Securing Flexible Duct Flexible duct must be installed with supports at maximum intervals of 1.5 metres. Flexible ductwork can be supported by using gaffer or electrical tape. Provided that it does not restrict the internal diameter of the ducting. Ducting installed loope...
Page 20 - Motor
Page 20 7. Measurements Motor Backdraft shutter Figure 9 Measurements for motor 160mm 85mm 350mm 295mm 190mm Dektite 50mm 275mm 430mm 200mm
Page 21 - Faulty Installation
Page 21 WARRANTY (See insert for more information) Motor has a 5-Year replacement product warranty. This is a change over warranty. The consumer is responsible for any charges associated with removal of the faulty unit and installation of the new unit. The customer is also responsible for any freigh...
Page 22 - Notes