Page 2 - Contents; [1] Connection of the Interface Board and; Input-Output Terminal
− 1 − Contents Parts Names and Dimensions ........ 2Connection ....................................... 4 [1] Connection of the Interface Board and Camera Unit .......................................................... 4 [2] Interface Board Specifications ............................... 4 Input-Outpu...
Page 3 - Parts Names and Dimensions; Dimensions
− 2 − Parts Names and Dimensions ■ Dimensions Note: The numbers within the brackets refer to the dimensions of the VCC-MD700 and MD800 models. ■ VCC-MD800/700/600/500 Series 7.1 25.1 29 8 60 12 16 Ǿ 40.5 ( Ǿ 38.6)* 18 50 84 3.53 (2.2) 7.1 25.1 29 8 12 16 18 4-M2 SCREW TAP 4-M2 SCREW TAP 3-M2 SCREW T...
Page 5 - [1] Connection of the Interface Board and Camera Unit; of the interface board using the necessary cables.; Connection; Connector; V PULSE; Input the signal of the following external tuning into
− 4 − [1] Connection of the Interface Board and Camera Unit Connect the camera unit and the interface board using the FFC (flexible flat cable). Connect the various terminals of the interface board using the necessary cables. DC12VGND V PULSE GND CN001 S0001 FFC B A CN002 CN003 CN004 CN005 Connectio...
Page 6 - Input-Output Terminal Descriptions; External Synchronization Specifications; Internal/External Synchronization
− 5 − Input-Output Terminal Descriptions [1] Input-Output Terminal Layout and Specifications Power Supply: DC 6-12V 1 RD 2 SD 3 GND 4 DC N (+6 – 12V) 5 GND (DC) 6 VIDEO 7 GND (VIDEO) 8 LINE IN 9 GND (LINE IN) CAMERA FFC Pin Number Signal Name Function I/O Signal Specifications 1 RD: RS-232C Communic...
Page 7 - Communications Speed:; transmissions; Communications Protocol
− 6 − [1] Communications Format The communication unit is a 4 (min)-24 (max) byte packet. ・ Communications Speed: 2400, 4800, 9600, 19200, 38400 9600 bps (DEFAULT MD800 – 500) * MD400 and MD300 cannot connect at 38400bps. DEFAULT is 19200bps. ・ Data Length: 8 bit ・ Start Bit: 1 bit ・ Stop Bit: 1 bit...
Page 8 - During Settings Command
− 7 − Communications Protocol [2] Communications Flow Note: ◦ Start the transmission of the next data after confirming the response command. ◦ The maximum transmission interval of the various byte data is 500 [msec]. If this is exceeded, a communication error is detected in the camera unit, the rece...
Page 21 - Note 1 Area Settings
− 20 − Communications Protocol Model: VCC-MD800/700/600/500/400/300 [7] Notes Note 1 Area Settings Divide the screen into 48 areas (6 vertical and 8 horizontal) and set an area to “1” to configure the mask and “0” to not configure the mask. On a row, bits 1 to 4 from the left are on the upper level ...
Page 22 - Note 2 Receiving Status; Status Command 1
− 21 − Note 2 Receiving Status Refer to the various status commands for contents of the reply when querying the status. Status Command 1 ⁃ Status1-1 Status1-2 Status1-3 Status1-4 Status1-5 Status1-6 bit0 Digital Zoom (0:OFF/1:ON) Focus (0:Auto/1:Manual) Menu Return (0:END/1:RETURN) * Only 22x models...
Page 24 - Note 3 Exclusive processing
− 23 − Note 3 Exclusive processing Setting to auto iris mode, when SENSE UP is set ⁃ When unable to set ・ Cannot be set when the motion sensor is set to ON. ・ Cannot be set when auto pursuit is set to ON. Auto switch setting ・ Sets AGC to ON. ・ Sets the shutter speed to normal settings. Set to auto ...
Page 26 - Status Response Command:
− 25 − Note 4 Orientation / angle display The display angle is changed using Pan/Tilt Degree commands. The Set North command sets the current position to N and the pan degree to 0. Pan angle versus orientation is as follows. N 337.6-22.5 NE 22.6-67.5 E 67.6-112.5 SE 112.6-157.5 S 157.6-202.5 SW 202....
Page 28 - Zoom Position Control; Direct; Function Descriptions
− 27 − [1] Zoom Control Zoom Position Control The zoom can be operated using Tele/Wide or moving the zoom to a specific position. Tele/Wide ⁃ Transmit the Tele or Wide command to execute the Tele/Wide operation at the speed configured by the Tele/Wide Speed command. The Stop command stops the operat...
Page 33 - *Query Command Mask Position responds in the; Details of the Mask Angle and Position; Setting the Mask Angle (Area Mask Degree Set)
− 32 − [11] Privacy Mask SettingsDisplay Area: NTSC (PAL) 0x26 (0x2A) 0x6C (0x6E) 0x9E (0x9F) 0xE4 (0xE3) 0x07 (0x0A) 0x35 (0x41) 0x54 (0x64) 0x82 (0x9B) * Area initially displayed using the Area Mask ON command. Notes: ・ Minimum unit for the mask width is 4 pixels horizontally and minimum unit for ...
Page 35 - Frequency that can be stabilized
− 34 − [12] Stabilizer (Only VCC-MD700/800 series) When this function is set to ON, the digital zoom magnifies the screen. When vibrations are detected, the vibrations are stabilized by changing the position of the screen captured by the zoom. Stabilizer level and digital zoom magnification When cha...
Page 36 - Detects movement on the screen and calculates the; Auto Pursuit ON/OFF Setting
− 35 − Function Descriptions [13] Auto Pursuit Function Detects movement on the screen and calculates the level of movement. Subject pursued: Walking person Area:1x Zoom, object = a person at 8m distance Speed: 4km/hour - 6km/hour Motion detection: Uses the motion detection function Detection area: ...
Page 37 - [1] Camera Control Command Transmission; -1 Control using the Command Button; Application Software; -2 Input Command Data Controls
− 36 − [1] Camera Control Command Transmission 1-1 Control using the Command Button The camera unit can be controlled by clicking the various command buttons. The command data transmitted and received by the PC can be confirmed using the “SENDING DATA” and “RECEIVING DATA” windows. Application Softw...
Page 38 - Spectral Sensitivity Characteristics
− 37 − Spectral Sensitivity Characteristics Relative Response Wave Length [nm] 1.0 0.8 0.6 0.4 0.2 0 Ye G Cy Mg 400 450 500 550 600 650 700 1.0 0.8 0.6 0.4 0.2 0 Ye G Cy Mg 400 450 500 550 600 650 700 Relative Response Wave Length [nm] Relative Response Wave Length [nm] 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0...
Page 39 - Specifications; • NTSC system
− 38 − Specifications • NTSC system Model VCC-MD800 VCC-MD700 VCC-MD600 VCC-MD500 VCC-MD400 VCC-MD300 36x ZOOM 30x ZOOM 22x ZOOM Day/night Color Day/night Color Day/night Color Image size 1/4" interline transfer CCD Effective picture elements 768(H) x 494(V) Lens 36x optical zoom f=3.4–122.4 mm,...
Page 40 - • PAL system
− 39 − Specifications • PAL system Model VCC-MD800P VCC-MD700P VCC-MD600P VCC-MD500P VCC-MD400P VCC-MD300P 36x ZOOM 30x ZOOM 22x ZOOM Day/night Color Day/night Color Day/night Color Image size 1/4" interline transfer CCD Effective picture elements 752(H) x 582(V) Lens 36x optical zoom f=3.4–122....
Page 41 - Change history
− 40 − 2006.12.20: the issue of ver 1.00 2007.02.15: the issue of ver 1.01 Changes the DEFAULT communication speed (BAUDRATE) of the MD800 – 500 to 9600 bps. • Newly added commands. • Cover Offset OFF/ONCover Offset LevelAuto Focus Mode during pan/tiltATW Mask DisplayCenter BLC Area DisplayBLC Mask ...
Page 42 - Shifting to digital zoom area
− 41 − Shifting to digital zoom area Pan/Tilt Degree commands Center BLC Area Direct commands Privacy Mask related commands Change history