Page 2 - CONTENTS
Note: 1. No part of this manual may be reproduced in any form without the expressed written permission of SANYO. 2. The contents of this manual are subject to change without notice. 3. Please contact SANYO if any point in this manual is unclear or if there are any inaccuracies. SANYO Electric Biomed...
Page 3 - PRECAUTIONS FOR SAFE OPERATION; important safety advice.; WARNING; possibly resulting in serious injury or death.; CAUTION; damage to the unit and associated property.
PRECAUTIONS FOR SAFE OPERATION It is imperative that the user complies with this manual as it contains important safety advice. Items and procedures are described so that you can use this unit correctly and safely. If the precautions advised are followed, this will prevent possible injury to the use...
Page 7 - CAUTIONS FOR USAGE; ENVIRONMENTAL CONDITIONS
CAUTIONS FOR USAGE 1. This unit is not explode-proof construction. Never store the materials which cause flammable or volatile gas and never store the flammable or volatile liquid in the unit. 2. The door glass, inside door panel, and exhaust vent are very hot when the unit is used with high tempera...
Page 8 - STERILIZER COMPONENTS
Page 10 - Control panel and keypad
STERILIZER COMPONENTS Control panel and keypad 1 2 3 4 5 6 7 8 1. Power switch (POWER): Power switch of the control panel. 2. Alarm buzzer stop key (BZ): Press this key to silence the buzzer in the event that the alarm operates and the buzzer sounds. Press it once again to reactive the buzzer. 3. Ti...
Page 11 - INSTALLATION; Installation site
INSTALLATION Installation site To operate this unit properly and to obtain maximum performance, install the unit in a location with the following conditions: 1. A location not subjected to direct sunlight or direct air flow from an air conditioner 2. A location with adequate ventilation Leave at lea...
Page 12 - Installation; BEFORE COMMENCING OPERATION; Prerunning
INSTALLATION Installation 1. Remove the packaging materials and tapes Remove all transportation packaging materials and tapes. Open the doors and ventilate the unit. If the outside panels are dirty, clean them with a neutral detergent and wipe it up with a wet cloth. 2. Adjust the leveling feet Exte...
Page 13 - OPERATING INSTRUCTIONS; Basic operating flow chart of control panel
OPERATING INSTRUCTIONS Basic operating flow chart of control panel 1. Start of operation when the input of setting is conducted. 12
Page 14 - Timer function
OPERATING INSTRUCTIONS Timer function The timer function has two modes as follows: 1. Normal mode: starts immediately after start of the running 2. Timer mode 1: starts when the chamber temperature is 2.0°C lower than the set point. When conducting the sterilization, always select "Timer mode 1&...
Page 15 - Stable running; d Ь; a о
OPERATING INSTRUCTIONS Stable running Table below shows the basic procedure for setting the chamber temperature. Perform key operations in the sequence indicated in the table. The example in the table is based on the assumption that the desiredtemperature is 50°C and continuous running. 50°C Time Ba...
Page 16 - Stable running with delay time; DO; Start of operation with no change of setting; BID
OPERATING INSTRUCTIONS Stable running with delay time 50°C Basic operation sequence (Example: Delay time Chamber temperature; 50°C, Delay time; 1 hour) Description of operation Key operated Indication after operation Press the power key. POWER О ALARM О DELAY О SET VALUE О START О MODE 1 E5\ (The cu...
Page 17 - Sterilization with timer mode 1; В В В D
OPERATING INSTRUCTIONS Sterilization with timer mode 1 200°C 2 hours Basic operation sequence (Example: 2 3 4 6 7 8 9 1 0 Description of operation Press the power key. (Release of delay set time)Press the delay timer key. Press the delay timer key to reset the delay time. Press the delay timer key a...
Page 18 - ALARMS & SAFETY FUNCTIONS
ALARMS & SAFETY FUNCTIONS This unit has the alarms and safety functions shown in table below, and also self diagnostic functions. Alarms and safety functions Alarm & Safety Automatic settemperature Alarm Auto return Key lock switch Temperature sensor abnormality Triacabnormality Relay abnorm...
Page 19 - ROUTINE MAINTENANCE; LWARNING; Cleaning of unit
ROUTINE MAINTENANCE LWARNING Always disconnect the power supply to the unit prior to any repair or maintenance of the unit in order to prevent electric shock or injury. Ensure you do not inhale or consume medication or aerosols from around the unit at the time of maintenance. These may be harmful to...
Page 20 - AWARNING
TROUBLE SHOOTING If the unit malfunctions, check out the following before calling for service. The unit does not operate at all 1. The unit is not plugged correctly into a power outlet. 2. The circuit breaker at the power source is active. 3. A power failure has occurred. 4. A fuse has blown. The ke...
Page 22 - Please f i l l in this form before servicing.; Safety check sheet
CAUTION Please f i l l in this form before servicing. Hand over this form to the service engineer to keep for his and your safety. Safety check sheet 1. Refrigerator contents : Risk of infection: Risk of toxicity: Risk from radioactive sources: •Yes • Y e s• Y e s• Y e s • No • No• No• No (List all ...