Page 3 - NSF
3 T ABLE OF C ONTENTS 1 SPECIFICATIONS ..................................................................................................................................................5 1.1 CVW-EXA284 / CVW-EXA224 ........................................................................................
Page 5 - Specifications; Model Name; Electrical
5 1 Specifications 1.1 CVW-EXA284 (H: 84 7/8”, L: 96 3/8”) / CVW-EXA224 (H: 84 7/8”, L: 144 5/8”) Model Name CVW-EXA284 CVW-EXA224 General Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh Produce) Cooling Capacity: 1224 BTU/h/ft. ( 2,880W ) 1224 BTU/h/ft. ( 4,321W ) Discharg...
Page 7 - Dimensions; External Dimensions
2 Dimensions 2.1 External Dimensions 2.2 Footprint ① Waste Outlet ② Electrical Connection ③ Refrigeration Outlet * Dimensions given in inches and millimeters (mm in parentheses). CVW-EXA284 / CVW-EXA224
Page 9 - Unloading and Carpentry Procedures; NSF Certification; WARNING
9 3 Unloading and Carpentry Procedures 3.1 NSF Certification The SANYO Cases described in this manual are built to meet the requirements of American National Standard/NSF International Standard 7. Each SANYO Case bears a nameplate identifying the type of application for which it was certified: Type ...
Page 10 - Aligning Cases; Case Leveling
10 3.5 Aligning Cases WARNING SANYO Cases are heavy and bulky, and require at least two people for unloading, moving, and installation. Do not walk on the top of the SANYO Cases. Walking on the top of the SANYO Case may lead to serious injury and/or damage to the SANYO Case. Do not place anything on...
Page 11 - Perimeter gasket is required by NSF.; Gasket
11 3.7 Joining Instructions 3.7.1 Applying gasket (for connecting cases or installing side panels). ① Make sure that all SANYO Cases are resting level. ② Make sure that all required parts for joining are present (gasket, bolts, joint covers, nuts, etc.). ③ Remove all Rear Interior Panels, Wire Racks...
Page 12 - Silicone seal
12 3.7.2 Connecting cases. ① Apply gasket as described above. ② Connect cases by using the attached bolts, joint covers, and nuts. Silicone seal Note: Gasket ends that are open must be sealed off by applying silicone at the installation site. Note: Connection point must be silicone sealed.
Page 13 - Installing Patch Ends
13 3.8 Installing Patch Ends 1. Apply gasket to case body (per previous instructions). 2. If present, remove protective film from inside wall of Patch End. 3. Place Patch End to line up with bolt holes. 4. From inside unit ratchet in M8 & optional M5 bolt into Patch End until secure. 5. Apply Si...
Page 14 - Installing Kickplate; and tighten accordingly.
14 3.9 Installing Kickplate 1. Align the mounting hole in the Kickplate with the slot in the Kickplate Mounting Bracket on the SANYO Case and tighten accordingly.
Page 15 - Installing Handrail and Bumper
15 3.10 Installing Handrail and Bumper Attaching the Bumper 1. Attach Maintenance Bumper (length 39-3/8 inches) to Bumper Brackets over the electrical connection box (“Raceway”) on each SANYO Case. The Raceway is located on the right end of each SANYO Case. 2. Attach Full-Length Bumpers between Main...
Page 16 - Refrigeration, Plumbing & Electrical Procedures; U-trap installation
16 4 Refrigeration, Plumbing & Electrical Procedures 4.1 Piping (Plumbing, Refrigeration) ● U-trap installation Install U-trap referring to the drawing below. ● Sealing the refrigerant pipe opening Seal pipe completely. Insufficient sealing may cause the following problems: Insufficient coolin...
Page 18 - Wiring Diagram
18 4.4.2 Wiring Diagram CVW-EXA284/184 CVW-EXA224/124
Page 19 - Operation; Load Limits; INCH MINIMUM; CORRECT
19 5 Operation 5.1 Load Limits In order to maintain proper temperature and unit performance, the Dual Air Curtains in each SANYO Case must remain unobstructed: Do not stock shelves beyond the marked load limits. Do not block Honeycombs or Return Air Grilles. Do not block airflow in any other w...
Page 20 - Installing FDA/NSF Thermometer; Magnet
20 Installing FDA/NSF Thermometer Suggested locations for the thermometer required by NSF/ANSI 7 and the FDA Food Code are indicated above. It is the responsibility of the Purchaser/End User of the SANYO Case to determine the location within the food storage area that best meets these code requireme...
Page 21 - Care and Cleaning Guidelines
21 6 Care and Cleaning Guidelines In order to keep SANYO Cases sanitary and in good working order, we recommend thorough periodic cleaning as follows: 6.1 Exterior Panels (Daily Cleaning) a. Exterior panels should be cleaned with water only. Wet a soft cloth and wring it out to wipe down panels. b. ...
Page 22 - Honeycomb Assemblies (at least every 3 months)
22 Please make sure to check and clean the drain trap at least once a month. Remove any material that has gathered in the drain trap and dispose of it. Clean the drain trap and put it back in its original position. 6.3 Honeycomb Assemblies (at least every 3 months) Because Honeycomb Assemblies may d...
Page 23 - Service; Replacing Fan Motors and Blades; HAND PROTECTION REQUIRED!; To replace the fan motors:; Remove the outer Air Curtain Duct Cover and socket covers.
23 7 Service 7.1 Replacing Fan Motors and Blades HAND PROTECTION REQUIRED! Activities to be undertaken require finger and palm protection to prevent personal injuries. To replace the fan motors: ① Remove the outer Air Curtain Duct Cover and socket covers. ② Unplug the fan motor harness and push thro...
Page 26 - Replacing Electronic Ballasts; Type Model Part; Electronic Ballast Part Codes; To replace electronic ballasts:; Remove the Exterior Top Panel.
26 7.2 Replacing Electronic Ballasts CVW-EXA124/224 CVW-EXA184/284 Type Model Part Number Quantity used Quantity used 3-lamp QHE3X32T8/UNV ISN-SC-1-CC-B 8FC05400000301 2 - 2-lamp QHE2X32T8/UNV ISN-SC-1-CC-B 8FC05400000201 - 2 WARNING! Make sure that all Electronic Ballasts Harness plugs are placed f...