Sanyo CH4272R H/P - Manuals

Sanyo CH4272R H/P – Manual in PDF format online.

Manuals:

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111

Summary

Page 2 - SPECIAL PRECAUTIONS; accidental injury or death.; WARNING; CAUTION

2 IMPORTANT! Please Read Before Starting This air conditioning system meets strict safety and operatingstandards. As the installer or service person, it is an impor-tant part of your job to install or service the system so it oper-ates safely and efficiently. For safe installation and trouble-free o...

Page 3 - Check of Density Limit; The density limit of refrigerant which is used in multi air con-; If there are 2 or more refrigerating systems in a sin-; For the amount of charge in this example:; N O T E

2. The standards for minimum room volume are as follows. (1) No partition (shaded portion) (2) When there is an effective opening with the adja- cent room for ventilation of leaking refrigerant gas(opening without a door, or an opening 0.15% orlarger than the respective floor spaces at the topor bot...

Page 4 - Item; Be sure to recharge the refrigerant only in liquid form.; defects of the unit.; Different tools required; Material; Precautions for Installation Using New Refrigerant; Care regarding tubing

4 R407C tools Item compatible Remarkswith R410A? Manifold gauge Yes No Types of refrigerant, refrigerating machine oil, and pressure gauge are different. Charge hose Yes No To resist higher pressure, material must be changed. Vacuum pump Yes Yes Use a conventional vacuum pump if it is equippedwith a...

Sanyo Manuals