Page 2 - Contents; User manual
2 English Contents User manual 4 Safety Information 4 Safety Information 4 At a Glance 14 Indoor Unit Overview 14 Home Duct Type 14 Cleaning and Maintenance 15 Cleaning and Maintaining 15 Cleaning the air filter 15 Periodical maintenance 16 Troubleshooting 17 Operation Ranges 20 Technical specificat...
Page 3 - Installation manual
3 English Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) shou...
Page 4 - to ensure that you know how to safely and efficiently operate the; WARNING; Safety Information
4 English Safety Information Safety Information Safety Information Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.Because the following operating instru...
Page 5 - FOR INSTALLATION; • Extending the power line may result in electric shock or fire.
5 English Safety Information Safety Information Symbol Meaning Flammable gas Flammable materials Refrigerant Safety Group A2L Refrigerant safety group Read operating manual Refer to operating manual Read service manual FOR INSTALLATION WARNING Use the power line with the power specifications of the ...
Page 7 - CAUTION
7 English Safety Information Safety Information Never install the outdoor unit in a location such as on a high external wall where it could fall. • If the outdoor unit falls, it may result in injury, death or property damage. This appliance must be properly grounded. Do not ground the appliance to a...
Page 8 - FOR POWER SUPPLY; • This may result in electric shock or fire.; FOR USING; • Failing to do so may result in electric shock or fire.
8 English Safety Information Safety Information FOR POWER SUPPLY WARNING When the circuit breaker is damaged, contact your nearest service centre.Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object o...
Page 12 - • This may result in burns or injury.
12 English Safety Information Safety Information Do not apply a strong impact to the remote controller and do not disassemble the remote controller.Do not touch the pipes connected with the product. • This may result in burns or injury. Do not use this air conditioner to preserve precision equipment...
Page 13 - FOR CLEANING
13 English Safety Information Safety Information FOR CLEANING WARNING Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner, alcohol or acetone to clean the appliance. • This may result in discoloration, deformation, damage, electric shock or fire. Before cleanin...
Page 14 - At a Glanc; Home Duct type; Air intake; NOTE; Indoor Unit Overview
14 English At a Glanc e At a Glanc e At a Glance Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air conditioner and stay cool or warm with optimal efficiency. Please read the user manual to get started and to make the best use of the air conditioner. H...
Page 15 - Cl; Cleaning and Maintaining; Cleaning the filter
15 English Cl eaning and Maint enanc e Cl eaning and Maint enanc e Cleaning and Maintenance Cleaning and Maintaining For the best performance from your air conditioner, clean it periodically. When cleaning, make sure to unplug from the unit for user’s safety. Cleaning the filter When cleaning the fi...
Page 16 - Periodical maintenance
16 English Cl eaning and Maint enanc e Cl eaning and Maint enanc e Periodical maintenance Unit Maintenance item Interval Requires qualified technicians Indoor unit Clean the air filter. At least once a month Clean the condensate drain pan. Once a year Required Clean up the heat exchange. Once a year...
Page 17 - Troubleshooting
17 English Cl eaning and Maint enanc e Cl eaning and Maint enanc e Problem Solution The product does not work.Error E601 • Connect an R-32-exclusive wired remote control.* MWR-WG01*N* R-32-exclusive wired remote controls should be purchased separately. An alarm sounds, and the product does not work....
Page 20 - Operation Ranges; Technical Specifications; Model specification (Dimension and weight)
20 English Cl eaning and Maint enanc e Cl eaning and Maint enanc e Operation Ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. MODE OPERATIONAL TEMPERATURE INDOOR HUMIDITY IF OUT OF CONDITIONS INDOOR...
Page 21 - Information about Refrigerant
21 English Cl eaning and Maint enanc e Cl eaning and Maint enanc e Important information: regulation regarding the refrigerant used This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere. CAUTION • If the system contains 5 tCO₂e or more of fluorinated greenhouse ga...
Page 22 - Ho; Checking the power connections; To connect the product to a Wi-Fi network,; Turning off “Switch to mobile data” at; Checking the Internet connectivity; Downloading the SmartThings app and; Downloading the SmartThings app; SmartThings app
22 English Cl eaning and Maint enanc e Ho w to use To use the SmartThings app, connect the product to the network in the sequence described below. The images shown may differ depending on your smartphone model, OS version and manufacturer. You need to set up the Wi-Fi access point only when connecti...
Page 23 - Registering your Samsung account; Connecting the SmartThings app to; Selecting the product to connect to; Connecting the SmartThings app to your
23 English Cl eaning and Maint enanc e Ho w to use 2 Registering your Samsung account • A Samsung account is required to use the SmartThings app. To create your Samsung account and log in to your account, follow the instructions displayed on the SmartThings app. You do not need to install an additio...
Page 24 - Open Source Announcement
24 English Cl eaning and Maint enanc e Ho w to use • If a failure message appears while adding a device, see “Setting up and connecting to a Wi-Fi access point using your smartphone” on page 22. The connection may fail temporarily due to an installation location problem of the access point or other ...
Page 26 - Regulatory Notice
26 English Cl eaning and Maint enanc e Ho w to use Regulatory Notice Wi-Fi Frequency Range Transmitter Power (Max) 2412 - 2472 MHz 20 dBm Bluetooth Frequency Range Transmitter Power (Max) 2402 - 2480 MHz 20 dBm Hereby, Samsung declares that this radio equipment is in compliance with Directive 2014/5...
Page 28 - Installation Manual; Installation Manual; Installation Manual; Installing the indoor unit; Installation Manual
28 English Installation Manual Installation Manual Installation Manual Installation Manual Installing the indoor unit It is recommended to install the Y-joint before installing the indoor unit. 1 Place the pattern sheet on the ceiling at the spot where you want to install the indoor unit. NOTE • Sin...
Page 29 - Performing Leak Test & Insulation; Leak test; Insulation
29 English Installation Manual Installation Manual Installation Manual Installation Manual When the drain hose is installed to the right. Drain hose port 3mm CAUTION • Noise will increase 3~6 dB(A) when the air flow enters from the bottom side (Only for Slim Duct/Home Duct Type product). Performing ...
Page 30 - Drain pipe and Drain Hose Installation
30 English Installation Manual Installation Manual Installation Manual Installation Manual 5 Select the insulation of the refrigerant pipe. • Insulate the gas side and liquid side pipe referring to the thickness according to the pipe size. • Indoor temperature of 30°C and humidity of 85% is the stan...
Page 31 - Drainpipe Connection; Centralized Drainage
31 English Installation Manual Installation Manual Installation Manual Installation Manual Metal clamp Drain socketDrain hose Be sure to bond the drain hose and the main pipe. Drain pipe Large seailng pad Drainpipe Connection Without the drain pump 1 Install horizontal drainpipe with a slope of 1/10...
Page 33 - Wiring work; Connecting the power and
33 English Installation Manual Installation Manual Installation Manual Installation Manual Wiring work Connecting the power and communication cables Power and communication cable connection • Before wiring work, you must turn off all power source.• Connect the power and communication cable among the...
Page 34 - Selecting the crimping terminal lug
34 English Installation Manual Installation Manual Installation Manual Installation Manual Wiring work Selecting the crimping terminal lug 1 Select the crimping terminal lug based on the norminal dimension of the power cable. 2 Cover the connection part of the power cable and crimping terminal lug t...
Page 35 - Specifications of the terminal blocks
35 English Installation Manual Installation Manual Installation Manual Installation Manual Specifications of the terminal blocks AC power: M4 screw Communication: M3.5 screw Unit: mm 11 7.5 9.0 13 18 13 .8 Power supply (single phase) MCCB ELB Min : 198V Max : 242V XA XA, 30 mA 0.1 s Power cable Eart...
Page 37 - Setting the indoor unit addresses and; Setting indoor unit addresses and installation option
37 English Installation Manual Installation Manual Installation Manual Installation Manual Setting the indoor unit addresses and the installation options You cannot set both of the indoor unit addresses and the installation options in a batch: set both of them respectively. Common steps for setting ...
Page 42 - installation location)
42 English Installation Manual Installation Manual Installation Manual Installation Manual 3 Check whether the option values that you have set are correct by pressing the (Mode) button repeatedly [SEG2, SEG3] [SEG14, SEG15] [SEG16, SEG17] [SEG18, SEG20] [SEG21, SEG22] [SEG23, SEG24] [SEG4, SEG5] [SE...
Page 43 - Setting the installation options in a batch
43 English Installation Manual Installation Manual Installation Manual Installation Manual Setting the installation options in a batch Option No. for an indoor unit address: 0AXXXX-1XXXXX-2XXXXX-3XXXXX Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Function Page Mode Setting main address 100-digit of an indoo...
Page 44 - Setting the indoor unit installation
44 English Installation Manual Installation Manual Installation Manual Installation Manual CAUTION • If you enter A to F to the SEG5 or SEG6, the indoor unit main address is not changed. • If you enter 0 to the SEG 3, the indoor unit maintains the previous main address although you enter the option ...
Page 45 - Installation options for the 02 series
45 English Installation Manual Installation Manual Installation Manual Installation Manual Installation options for the 02 series SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 0 2 Evaporator Drying Use of external room temperature sensor / Minimizing fan operation when thermostat is off Use of central control FAN R...
Page 50 - 5 series installation option
50 English Installation Manual Installation Manual Installation Manual Installation Manual (*7) This function can be applied to 4 Way Cassette and Mini 4 Way Cassette only. If the air conditioner operates the heating mode immediately after finishing the cooling mode, the condensate water in the drai...
Page 55 - Changing the addresses and options individually
55 English Installation Manual Installation Manual Installation Manual Installation Manual Changing the addresses and options individually When you want to change the value of a specific option, refer to the following table and follow the steps in Common steps for setting the addresses and options o...