Rheem 871024-B- Manuals
Rheem 871024-B– User Manual in PDF format online.
Manuals:
User Manual Rheem 871024-B
Summary
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 10 Updated 19/07/2013 1 INTRODUCTION 1.1 GENERAL CONTRACT REQUIREMENTS All proposals shall comply with this ”Minimum Specification” together with any additional requ...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 13 Updated 19/07/2013 14. Discuss and agree any variations to the plans; and 15. Mark on the site plan, and photograph, any dilapidation of the council infrastructur...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 14 Updated 19/07/2013 2. DESIGN REQUIREMENTS 2.1 GENERAL This specification shall be for Class 1 buildings as defined by the Building Code of Australia Housing SA ha...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 18 Updated 19/07/2013 When located on the boundary the wall shall be designed so that it requires little or no maintenance from the neighbour’s property and achieves...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 23 Updated 19/07/2013 For certain occupants with specific special needs, increased robustness of ceiling linings may need to be considered. Where this is required it...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 24 Updated 19/07/2013 The designer is to design the building to meet the requirements for bush fire protection and the proponent shall have deemed to have allowed fo...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 27 Updated 19/07/2013 3.1.7 Manuals At Practical Completion and as a requirement for Practical Completion provide 3 copies of the Operation and Maintenance manuals f...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 30 Updated 19/07/2013 Remove from site all rubbish, Builders debris, weeds, unwanted plant growth and loose rocks from external areas, including making good council ...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 38 Updated 19/07/2013 3.3.17.1 Tank Stand for Rainwater tank plumbed to toilets (usually 1000 Litres) Stand shall be constructed from galvanized steel and shall be d...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 45 Updated 19/07/2013 Mix materials until uniform in colour and consistency. Do no remix or add to fresh mortar any mix showing signs of initial set. 3.4.16.4 Render...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 51 Updated 19/07/2013 Sand joins if necessary to achieve a flat floor. Protect floor surfaces in accordance with the manufacturer’s recommendations. 3.5.10.2 Wet Are...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 54 Updated 19/07/2013 The sheet materials shall be laid horizontally, with staggered joins, if room length sheets are not possible, and fixed into the studs as per t...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 55 Updated 19/07/2013 3.8.3 Protection Ensure that the windows and window frames are protected against damage for the duration of the contract period. Any damage sha...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 56 Updated 19/07/2013 • Combination Doors (CombiDoor) shall be a solid core door with an opening glass panel and mesh security grille all set in an aluminium frame, ...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 59 Updated 19/07/2013 Furniture shall be matching throughout each house. Provide privacy sets to W.C.s, and bathrooms with external release. Deadlocks are not to be ...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 68 Updated 19/07/2013 3.15.2 Paint Types The following paint types shall be used 3.15.2.1 Timber And Timber Products Finishes Relevant to Contract All exposed surfac...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 69 Updated 19/07/2013 • One coat of pigmented sealer (solvent borne) to APAS 0171 • One coat of exterior/interior undercoat to APAS 0016/1 • Two coats of satin alkyd...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 70 Updated 19/07/2013 Apply to zincanneal, galvanised, zincalume, lead flashings and zinc silicate treated steel surfaces. Degrease with an approved commercial degre...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 71 Updated 19/07/2013 3.15.2.4 External Walls And Soffits Fibre Reinforced Cement Board, Masonry & Rendered Surfaces Apply to F.R.C.B. masonry and rendered surfa...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 78 Updated 19/07/2013 3. 16.11 Hot water service 3.16.11.1 Hot Water Units Hot water services are to be provided and installed by Others. The Proponent must select o...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 79 Updated 19/07/2013 UNLESS Solar has been specified select a Gas storage or Gas continuous flow from the table. For properties specified to have solar units unless...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 81 Updated 19/07/2013 • A pipe from the position of the roof mounted tank into a tundish or a gully connected to the sewer for the pressure relief water. The exposed...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 94 Updated 19/07/2013 Where Council/Encumbrance requirements call for masonry unit paving provide minimum 60mm thick interlocking pavers for vehicular driveways and ...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 97 Updated 19/07/2013 TERMITE PROTECTIVE TREATMENT PROCEDURES TERMITE PROTECTIVE TREATMENT PROCEDURES, JUNE 2012 The following systems are to be used to provide long...
General Construction Part B – Specification and Response Requirements Annexure 2- Minimum Design & Construction Specification Page 102 Updated 19/07/2013 STANDARD DETAILS Retaining Wall Details Part 1 Sleeper Retaining Wall for Cut Sites (type 1) Sleeper Retaining Wall for Fill Sites (type 2) Re...
Rheem Manuals
-
Rheem Professional Classic Series: Ultra Low NOx Power Vent
User Manual
-
Rheem Classic Series: 80% AFUE Single-Stage PSC Motor
User Manual
-
Rheem 311 Series
User Manual
-
Rheem RUTGH-84DV
User Manual
-
Rheem 38.5
User Manual
-
Rheem 38.5
Manual
-
Rheem RUUD Commercial StorageTanks
User Manual
-
Rheem HG
User Manual
-
Rheem HG
Manual
-
Rheem RTGH-84V
User Manual
-
Rheem ECOH160DV
User Manual
-
Rheem 900 BTU Max input
User Manual
-
Rheem 900 BTU Max input
Manual
-
Rheem Single Element
User Manual
-
Rheem GE50M06AAG
User Manual
-
Rheem Marathon CMR50245
User Manual
-
Rheem Guardian PowerVent
User Manual
-
Rheem Guardian PowerVent
Manual
-
Rheem XE40H06TT45U0
User Manual
-
Rheem Professional Classic Series: Atmospheric for Manufactured Housing
User Manual