Page 2 - GENERAL SAFETY RULES; ELECTRICAL SAFETY
2 GENERAL SAFETY RULES ELECTRICAL SAFETY 1. Use battery operated rotary level with alkaline batteries only. Use of any other batteries may permanently damage the rotary level. PERSONAL SAFETY 1. Stay alert, watch what you are doing, and use common sense when operating a laser. Do not use rotary leve...
Page 3 - FUNCTIONAL DESCRIPTION; FOREWORD; ASSEMBLY; Rotary Level Features; • Receives radio frequency commands from Remote Control
3 FUNCTIONAL DESCRIPTION FOREWORD Porter-Cable Model LR 1100 Rotary Level is a self-leveling, remote-controlled, precision laser level of superior quality that is time-saving and easy to use. Place it on any surface and the perfectly balanced, self-leveling pendulum insidethe device takes care of th...
Page 4 - OPERATION; Quick Guide to Using Rotary Level; The One Minute Set-Up
4 OPERATION Quick Guide to Using Rotary Level The One Minute Set-Up 1. Set the Base Unit up on a tripod or any surface that is within 10° of level. There are two tripod mounts built into the bottom ofthe Adjusting Base - a 5/8" x 11 (standard transitlevel tripod) and 1/4" x 20 (camera-type t...
Page 5 - Using the Remote Control; Finding The Laser Dot; Never look directly into the laser source as this may cause eye; Replacement Remote Control can be purchased separately.
5 Using the Remote Control The Remote Control is one of the features that makes Rotary Level unique in thefield of laser leveling systems. Using the Remote Control, you can control therotation of the Base Unit from up to 100 feet away! You don't even have to be "insight" of the Base Unit bec...
Page 6 - Battery replacement; Pop the battery out by lifting from the bottom of the battery.
6 Battery replacement Base Unit - 4 "AA" Alkaline Batteries 1. Unscrew the battery housing cover using either your fingers or a coin. Lift the cover off. 2. Insert the new batteries according to the illustrations on the battery slots.3. Replace the battery housing cover and tighten the screw...
Page 7 - Recalibration; Make sure the laser is off (Remote Control
7 Recalibration Rotary Level can be recalibrated by you, in the field. If Rotary Level is dropped,you should recalibrate. 1. Choose your recalibration site. To get the most accurate calibration possible, it is best to use two vertical (plumb) surfaces directly opposite each other,100' apart (50' min...
Page 8 - You should now have two spots marked on Surface A. Any difference
8 8. Move the base unit to about 5' from Surface B (the location you just marked). Raiseor lower the Base Unit so that the laser dot hits the spot you have already marked. 9. Using the Remote Control, rotate the Base Unit until the laser dot is exactlyon, directly above, or directly below the point ...
Page 9 - Troubleshooting; When the...; Specifications; Line Generation Feature:
9 Troubleshooting When the… LED does not come on when Lens Cover is up. LED and Laser blinkcontinuously. Remote Control will not drive the Base Unit. Laser & LED shut offwithout warning blinks. Base Unit will not moveon Adjusting Base. The batteries in the Base Unit may need to bechanged. Change...
Page 10 - Line Generating Feature; The center section of the line; User Safety; These labels are attached to every Rotary Level.; FCC Statement
10 Line Generating Feature You have just purchased your Self-Leveling, Remote Controlled Laser,Rotary Level with the new line-generating feature. The following outlines theoperation of the feature with your Rotary Level. The line-generating feature converts Rotary Level’s single laser dot into a lin...
Page 11 - GENERAL MAINTENANCE; KEEP TOOL CLEAN; DELTA FACTORY SERVICE CENTER. All repairs made by these
11 - Reorient or relocate the receiving antenna- Increase the separation between the equipment and receiver- Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to thefollowing two conditions:(1) This device may ...
Page 12 - REPLACEMENT PARTS LIST; ACCESSORIES; elta Factory Service Centers, and Porter-Cable; ONE YEAR WARRANTY
12 REPLACEMENT PARTS LIST 905898 ANTENNA 905899 REMOTE CONTROL 905900 REMOTE CONTROL BATTERY COVER 905901 BATTERY COVER SCREW905907 BATTERY COVER 905972 CALIBRATION PORT PLUG ACCESSORIES A complete line of accessories is available from your Porter-CableSupplier, Porter-Cable • D elta Factory Service...