Page 2 - GB; ENGLISH
2 Matthew G. PopikVice President of Engineering PORTER ✦✦ CABLE Porter-Cable Corporation4825 Highway 45 NorthJackson, TN 38305 Date of Manufacture: ___________________________ Fecha de fabricación:, Date de fabrication: Serial No: ______________________________________ Número de serie:, Nombre d'ord...
Page 3 - SAFETY GUIDELINES / DEFINITIONS; SAVE THESE INSTRUCTIONS!; IMPORTANT SAFETY INSTRUCTIONS; READ AND FOLLOW ALL INSTRUCTIONS.
3 indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. indicates a potentially hazardous situation which, if not avoided, may result in mi...
Page 4 - GENERAL SAFETY RULES
4 Fig. 6 Fig. 5 Fig. 2 Fig. 3 Fig. 4 1. Read and understand tool labels andmanual. Failure to follow warnings could result in DEATH or SERIOUS INJURY . Fig. 1. 2 . Operator and others in work area MUST wear safety glasses with side shields. These safety glasses must conform to ANSIZ87.1 requirements...
Page 6 - TECHNICAL SPECIFICATIONS
6 21. Remove finger from trigger when not driving fasteners. Never carry tool with fingeron trigger. In “Contact Actuation Mode” toolwill fire a fastener if safety is bumped whiletrigger is depressed. Fig. 14. 22. Do not overreach. Keep proper footing a n d b a l a n c e a t a l l t i m e s w h e n ...
Page 7 - EMPLOYER’S RESPONSIBILITIES
7 Employer must enforce compliance with the safety warnings and all other instructions contained in this manual. Keep this manual available for use by all people assigned to use this tool. For personal safety and proper operation of this tool, read and understandtool labels and manual. Failure to fo...
Page 8 - Fasteners must point in the same direction as they will be
8 Do not load fasteners with trigger or safety depressed.Only use approved Porter-Cable fasteners.Operator and others in work area MUST wear safety glasses with side shields. Always wear ANSI Z87.1 approved safety glasses, and ANSI S3.19 approved hearing protection when preparing or operating the to...
Page 9 - USING THE TOOL WITH SELECTABLE TRIGGERING OPTIONS; OPERATING INSTRUCTIONS
9 USING THE TOOL WITH SELECTABLE TRIGGERING OPTIONS Complete all steps of PREPARING THE TOOL before using the tool. This tool is shipped from the factory with a selectable trigger set in the “SINGLE SEQUENTIAL ACTUATION” firing mode as described in number 1 below. The selectable trigger can be set f...
Page 10 - Do Not
10 Keep fingers AWAY from trigger when not driving fasteners to avoid accidental firing. Never carry tool with finger on trigger. In “Contact Actuation Mode” tool will fire a fastener if safety is bumped while trigger is depressed. Never point tool at yourself or others. Never attempt to drive a fas...
Page 11 - CLEARING A JAMMED FASTENER; Disconnect tool from air supply.
11 CLEARING A JAMMED FASTENER Disconnect tool from air supply. 1. Remove any remaining fasteners from the nailer. A. Pull follower all the way to the rear, until it latches (A) Fig. 26. B. Slide fasteners to the rear, and remove from magazine (see Fig. 27). 2. Use a pair of needle nose pliers and/or...
Page 12 - CLEAN AND INSPECT DAILY; D i s c o n n e c t t o o l f r o m a i r s u p p l y b e f o r e c l e a n i n g a n d; SERVICE AND REPAIRS; MAINTENANCE
12 CLEAN AND INSPECT DAILY D i s c o n n e c t t o o l f r o m a i r s u p p l y b e f o r e c l e a n i n g a n d inspection. Correct all problems before placing the tool back in use. Wipe tool clean and inspect for wear or damage. Use non-flammablecleaning solutions to wipe exterior of tool only i...
Page 13 - TROUBLESHOOTING; Disconnect tool from air supply before performing any Service; for a catalog or for the name of your nearest supplier.; ACCESSORIES
13 TROUBLESHOOTING Disconnect tool from air supply before performing any Service Procedure. SYMPTOM PROBLEMS SOLUTIONS 1. Air leak near top of Loose screws. Tighten screws. tool or in trigger area. Worn or damaged Install Overhaul Kit. o-rings or seals. 2. Tool does nothing or Inadequate air supply....