Page 2 - SAFETY GUIDELINES - DEFINITIONS; YOUR SAFETY; and; PREVENTING EQUIPMENT PROBLEMS; . To help you recognize this; IMPORTANT SAFETY INSTRUCTIONS; drilling, and other construction activities contains chemicals
2 - ENG D26130 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situ...
Page 3 - Save these instructions; WARNING: Risk of explosion or fire
3 - ENG D26130 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury andproperty damage. Read and understand all warnings and operation instructions beforeusing this equipment. HAZARD WARNING: Risk of explosion or fire ...
Page 4 - HAZARD
4 - ENG D26130 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. How To Prevent It What Could Happen WARNING: Risk from Flying Objects The compressed air stream...
Page 7 - WARNING: Risk of Unsafe Operation; SAVE THESE INSTRUCTIONS
7 - ENG D26130 Review and understand all instructions and warnings in this manual. Become familiar with the operation andcontrols of the air compressor. Keep operating area clear of all persons, pets, and obstacles. Keep children away from the air compressor at all times . Do not operate the product...
Page 8 - CFM; SPECIFICATIONS
8 - ENG D26130 GLOSSARY DUTY CYCLE Accessories for this unit are available at the store the unit was purchased. ACCESSORIES Become familiar with these termsbefore operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of airdelivery. PSIG: Pounds per...
Page 9 - ASSEMBLY; Unpacking; Remove unit from carton and discard all packaging.; DO NOT USE; The outlet being used; INSTALLATION; HOW TO SET UP YOUR UNIT; Location of the Air Compressor
9 - ENG D26130 ASSEMBLY Unpacking 1. Remove unit from carton and discard all packaging. 2. Make sure the outlet being usedhas the same configuration asthe grounded plug. DO NOT USE AN ADAPTER. See illustration. 3. Inspect the plug and cord beforeeach use. Do not use if there aresigns of damage. 4. I...
Page 10 - Extension Cords; in good condition; Voltage and Circuit Protection; Certain air; If compressor
10 - ENG D26130 Extension Cords Using extension cords is notrecommended. The use of extensioncords will cause voltage to dropresulting in power loss to the motorand overheating.Instead of using an extension cord,increase the working reach of the airhose by attaching another length ofhose to its end....
Page 11 - Outlet Pressure Gauge:; The outlet; Description of Operation; The pressure; OPERATION; Know Your Air Compressor
Outlet Pressure Gauge: The outlet pressure gauge indicates the airpressure available at the outlet side ofthe regulator. This pressure iscontrolled by the regulator and isalways less than or equal to the tankpressure. Regulator: Controls the air pressure shown on the outlet pressure gauge.Turn regul...
Page 12 - Before Starting; Risk of Unsafe; How to Use Your Unit
Before Starting Break-in Procedure Risk of Unsafe Operation. Serious damage may result if the followingbreak-in instructions are not closely followed. This procedure is required before the air compressor is put into service andwhen the check valve or a completecompressor pump has been replaced. 1. M...
Page 13 - MAINTENANCE; Customer Responsibilities
13 - ENG D26130 Before Each Start-Up: 1. Place On/Auto/Off lever to"OFF". 2. Turn the regulator knob counter-clockwise to set the outletpressure to zero. 3. Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the airoutlet is equipped with a quickcon...
Page 14 - To Drain Tank; Remove the air tool or accessory.; Water will condense; If drain valve is; To Replace or Clean Check; The hose; SERVICE AND ADJUSTMENTS; Risk of Unsafe Operation. Unit cycles automatically when
14 - ENG D26130 To Drain Tank 1. Set the On/Auto/Off lever to"OFF". 2. Turn the regulator knob counter-clockwise to set the outletpressure to zero. 3. Remove the air tool or accessory. 4. Pull ring on safety valve allowingair to bleed from the tank untiltank pressure is approximately20 psi. ...
Page 15 - NOTE; To Replace Regulator; Remove the regulator.
5. Make sure the valve disc movesfreely inside the check valve andthe spring holds the disc in theupper, closed position. Thecheck valve may be cleaned witha solvent, such as paint andvarnish remover. 6. Apply sealant to the check valvethreads. Reinstall the check valve(turn clockwise). 7. Replace h...
Page 16 - STORAGE; If drain valve is plugged,
16 - ENG D26130 STORAGE Before you store the air compressor,make sure you do the following: 1. Review the "Maintenance"section on the preceding pagesand perform scheduledmaintenance as necessary. 2. Set the On/Auto/Off lever to"OFF" and unplug unit. 3. Turn the regulatorcounterclockw...
Page 17 - NOTES
Page 18 - LIMITED WARRANTY
LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include aircompressors, air tools, service parts, pressure washers, and generators, which...