Page 2 - SAFETY GUIDELINES - DEFINITIONS; stand. This information relates to protecting; IMPORTANT SAFETY INSTRUCTIONS
2 - ENG A09770 SAFETY GUIDELINES - DEFINITIONS Indicates an imminent-ly hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous sit...
Page 3 - Save these instructions; HAZARD; WARNING: Risk of explosion or fire
3 - ENG A09770 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fir...
Page 6 - WARNING: Risk of Burns; WARNING: Risk from Moving Parts
6 - ENG A09770 WARNING: Risk of Burns Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach...
Page 7 - WARNING: Risk of Unsafe Operation; SAVE THESE INSTRUCTIONS
7 - ENG A09770 Review and understand all instructions and warnings in this manual. Become familiar with the operation and controls of the air compressor. Keep operating area clear of all persons, pets, and obstacles. Keep children away from the air compressor at all times . Do not operate the produc...
Page 8 - CFM; SPECIFICATIONS
8 - ENG A09770 GLOSSARY DUTY CYCLE Accessories for this unit are available at the store the unit was purchased. ACCESSORIES Become familiar with these terms before operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds p...
Page 9 - ASSEMBLY; Unpacking; Remove unit from carton and discard all packaging.; GROUNDING INSTRUCTIONS; INSTALLATION; HOW TO SET UP YOUR UNIT; Location of the Air Compressor; This unit needs no lubrication or oiling.
9 - ENG A09770 ASSEMBLY Unpacking 1. Remove unit from carton and discard all packaging. IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances. 2. Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN...
Page 10 - Certain air
10 - ENG A09770 Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating.Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to i...
Page 11 - OPERATION; Know Your Air Compressor; READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING; Description of Operation; Outlet Pressure Gauge:
11 - ENG A09770 OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Tank Pressure Gauge ...
Page 12 - Before First Start Up; Risk of Unsafe; How to Use Your Unit
Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-...
Page 13 - The hose or accessory will; MAINTENANCE; Customer Responsibilities; - more frequent in dusty or humid conditions
13 - ENG A09770 Before Each Start-Up: 1. Place On/Auto/Off lever to "Off".2. Turn the regulator knob counter- clockwise to set the outlet pressure to zero. 3. Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick...
Page 15 - SERVICE AND ADJUSTMENTS; Risk of Unsafe Operation. Unit cycles automatically when
6. Unscrew elbow fitting from the check valve (turn counter- clockwise) using an adjustable wrench. Note the orientation of the elbow fitting for reassembly. 7. Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve disc should move freely up and down on a spring which holds...
Page 16 - NOTE; To Replace Regulator
16 - ENG A09770 6. Assemble the regulator and orient as shown. NOTE : Arrow indicates flow of air. Make sure it is pointing in the direction of air flow. 7. Reapply pipe sealant to outlet pressure gauge and quick connect. 8. Reassemble outlet pressure gauge and quick connect. Orient outlet pressure ...
Page 17 - STORAGE; Water will condense
17 - ENG A09770 STORAGE Before you store the air compressor, make sure you do the following:1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the On/Auto/Off lever to "Off" and unplug unit. 3. Turn the regulator counterc...
Page 18 - TROUBLESHOOTING; Check valve seat damaged.
18 - ENG A09770 TROUBLESHOOTING Risk of Unsafe Operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source...
Page 19 - Adjust the regulated
19 - ENG A09770 PROBLEM CAUSE CORRECTION It is normal for "some" pressure drop to occur. If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation Sect...
Page 21 - NOTES
Page 22 - LIMITED WARRANTY
22 - ENG A09770 LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and ...