Page 2 - SAFETY GUIDELINES - DEFINITIONS; understand. This information relates to protecting; IMPORTANT SAFETY INSTRUCTIONS
2- ENG A08188 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situa...
Page 3 - Save these instructions; HAZARD; WARNING: Risk of explosion or fire
3- ENG A08188 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire...
Page 6 - WARNING: Risk of Burns; WARNING: Risk from Moving Parts
6- ENG A08188 WARNING: Risk of Burns Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach ...
Page 7 - WARNING: Risk of Unsafe Operation; SAVE THESE INSTRUCTIONS
7- ENG A08188 Review and understand all instructions and warnings in this manual. Become familiar with the operation and controls of the air compressor. Keep operating area clear of all persons, pets, and obstacles. Keep children away from the air compressor at all times . Do not operate the product...
Page 8 - CFM; SPECIFICATIONS
8- ENG A08188 Model No. C2150 Running Horsepower 1.2 Bore 2-3/8" Stroke 1.35" Voltage-Single Phase 120 * * Minimum Branch Circuit Requirement 15 amps * Fuse Type Time Delay Air Tank Capacity (Gallon) 4.0 Approximate Cut-in Pressure 120 PSIG Approximate Cut-out Pressure 150 PSIG SCFM @ 40 PSI...
Page 9 - HANDLE ASSEMBLY; To make installation easier, submerge; ASSEMBLY; RECOMMENDED HANDLE
HANDLE ASSEMBLY 1. To make installation easier, submerge handle grip (C) into warm soapy water. Remove handle grip (C) from soapy water and slide onto handle (D). 2. Press tube plugs (E) into frame assembly as shown. 3. Attach handles (D) to frame using knobs (F) and saddle bolts (G) supplied. Choos...
Page 10 - INSTALLATION; GROUNDING INSTRUCTIONS; MUST be used with a grounded outlet.; DO NOT USE AN; Inspect the plug and cord before each; HOW TO SET UP YOUR UNIT; Location of the Air Compressor
10- ENG A08188 INSTALLATION GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The portable air compressor is equipped with a cord h...
Page 11 - Extension Cords; in good condition; Voltage and Circuit Protection; If compressor is connected to a circuit protected by fuses,
11- ENG A08188 Extension Cords Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor, and to prevent overheating.If an extension cord must be used, be sure it is:• a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will...
Page 12 - Description of Operation; Outlet Pressure Gauge:; OPERATION; Know Your Air Compressor
12- ENG A08188 Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch : Turn this switch "ON/AUTO" to provide automatic power to the pressure switch and "OFF" to remove power at the end of each use. Pressure Switch: The pressure swi...
Page 13 - Pressure Release Valve:; How to Use Your Unit; Before Starting; Break-in instructions; before
13- ENG A08188 Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank. Press...
Page 14 - The hose or accessory will require a; MAINTENANCE; Customer Responsibilities; - more frequent in dusty or humid conditions
14- ENG A08188 How to Start: 1. Turn the On/Auto/Off lever to "ON/AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure. 2. Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push k...
Page 15 - Air Filter Inspection and Replacement; to cool prior to servicing.; To Check Safety Valve; If the safety valve does not work properly, over-; operate smoothly, it must be replaced with the same type of valve.; To Drain Tank; pressure is approximately 20 psi. Release safety valve ring.; NOTE
15- ENG A08188 Air Filter Inspection and Replacement Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed. Allow compressor to cool prior to servicing. Keep the air filter clean at all times. Do not operate the air compressor with the air filter removed. A dirty air ...
Page 16 - Air Compressor Pump Intake and Exhaust Valves; SERVICE AND ADJUSTMENTS; To Replace or Clean Check Valve
16- ENG A08188 Air Compressor Pump Intake and Exhaust Valves Once a year have a Trained Service Technician check the air compressor pump intake and exhaust valves. If it is dirty, replace it with a new filter. 1. Remove the air filter cover.2. Remove the air filter from filter cover.3. Place new air...
Page 17 - To Replace Regulator
17- ENG A08188 6. Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve disc should move freely up and down on a spring which holds the valve disc in the closed position; if not the check valve needs to be cleaned or replaced. 7. Clean or replace the check valve. A solvent,...
Page 18 - STORAGE; scheduled maintenance as necessary.; Water will condense in the air tank. If not drained, water; After the water has been drained, close the drain or drain valve.; RECOMMENDED
18- ENG A08188 STORAGE Before you store the air compressor, make sure you do the following:1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the On/Auto/Off lever to "OFF".3. Turn the regulator counterclockwise and set t...
Page 19 - TROUBLESHOOTING; Check valve seat damaged.
19- ENG A08188 TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE C...
Page 20 - Adjust the regulated
20- ENG A08188 PROBLEM CAUSE CORRECTION It is normal for "some" pressure drop to occur. If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation Secti...
Page 22 - LIMITED WARRANTY
22- ENG A08188 LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and g...