Page 2 - T IS OBLIGATORY TO READ AND KEEP THIS INSTRUCTION MANUAL; TABLE OF CONTENTS
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 2 I T IS OBLIGATORY TO READ AND KEEP THIS INSTRUCTION MANUAL . TABLE OF CONTENTS 1. INTRODUCTION .......................................................................................................................................
Page 4 - INTRODUCTION; It is obligatory; CE Declaration of conformity
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 4 1. INTRODUCTION The GaLiO Corten fireplace is a decorative fuel-effect gas appliances intended only for outdoor use. It is obligatory to acquaint oneself with the below installation manual and user’s manual before committing to...
Page 6 - SAFETY INSTRUCTIONS; Read the instructions before using the appliance.; When the GaLiO Corten fireplace is on it’s not to be exposed to rain.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 6 2. SAFETY INSTRUCTIONS • Read the instructions before using the appliance. • Use outdoors only. • The GaLiO Corten fireplace should be installed and serviced annually according to the below installation manual as well as enforc...
Page 7 - Safety instruction regarding the use of the gas cylinders.; The gas cylinder needs to be shut if the fireplace is not being used.; INSTALLATION; Box contents
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 7 • Corrosion of the coating of the base of GaLiO Corten is a natural process resulting from the characteristics of the Corten steel which the fireplace is made of. It is an additional protective layer of the appliance against th...
Page 8 - Unboxing and installation; Remove the Styrofoam placed on the unit.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 8 • 1x complete Galio Corten gas fireplace • 1x remote control • 4x Tempered glass guards • 1x Touch panel (installed) • 4x AA Batteries • 2x AAA Batteries • 4x bag of decorative stones • 1x AS/NZS 1869 hose assembly – installed ...
Page 9 - WARNING; Do not install under trees or overhanging branches.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 9 Photo 2 • If all the points were completed according to the instruction the gas bottle can be now connected (See point 3.4.2). WARNING !!! All elements above the fireplace need to be made of non-flammable materials. • Select a ...
Page 12 - Installation of glass screens; Carefully remove cardboard and foam foil from the glass guards.; Remove the glass guards only in case of damage of the glass.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 12 3.3. Installation of glass screens • Carefully remove cardboard and foam foil from the glass guards. • Remove all contaminations from the glass guards which could burn out on the glass during operation of the GaLiO Corten (in ...
Page 14 - OPERATING INSTRUCTIONS; General Notes; held transmitter or receiver.; The appliance is delivered already configured and ready to work.; learn the hand-held transmitter’s signal code before the first use:; the “; RESET
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 14 4. OPERATING INSTRUCTIONS 4.1. General Notes The GaLiO Corten Remote fireplace has a remotely control valve with a built-in ignition for the pilot flame. The flame height of the main burner may be appropriately regulated by re...
Page 15 - Replacing the batteries
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 15 Photo 4: Receiver “RESET” button 4.3. Replacing the batteries If the batteries are inserted incorrectly, the electronics or drive may be irreparably damaged. Only replace the batteries when the appliance has been completely sw...
Page 17 - Place the new batteries into the container.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 17 • To remove the second battery, insert the magnetic gripper into the battery container. Photo 8: Removing the second battery from the container • Place the new batteries into the container. WARNING! Remember about proper polar...
Page 18 - Screw the cover of the batteries container.; Hand-held transmitter; fully charged; Open the cover on the back of the transmitter.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 18 • Screw the cover of the batteries container. • Repeat the same procedure for changing the batteries in the second container. 4.3.2. Hand-held transmitter The hand-held transmitter batteries have a service life of approx. one ...
Page 19 - Remote control; Software Version; ON
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 19 4.4. Remote control GaLiO Corten Remote is operated by radio remote control. This comprises a hand-held transmitter and a receiver. The receiver is part of the gas control block assembly. Figure 5: Display hand-held transmitte...
Page 21 - Setting the Time; Day; Switch on the Appliance / Igniting the Fire
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 21 4.4.3. Setting the Time 1. Press and buttons simultaneously. Day flashes. 2. Press or button to select a number to correspond with the day of the week (1=Monday, 2 = Tuesday, 3 = Wednesday, 4 = Thursday, 5 = Friday, 6 = Saturd...
Page 22 - Gradually decrease flame height
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 22 • This can take few seconds to ignite to pilot flame especially when you have replaced and installed a new LPG gas cylinder. • If the pilot light does not ignite after 3 ignition attempts close the gas tap and warn the fitter....
Page 23 - Flame height directly to minimum position; LO; Gradually increase flame height
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 23 4.4.6. Flame height directly to minimum position Pressing the button twice automatically decreases the flames to the low position. This is indicated by “ LO ” on the display. NOTE: Flame goes to high fire first before going to...
Page 24 - Flame height directly to maximum position
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 24 4.4.8. Flame height directly to maximum position Pressing the button twice automatically increases the flames to the high position. This is indicated by “ HI ” on the display. NOTE: Backlight must be on for high fire double-cl...
Page 25 - Turning off the device; OFF; Countdown Timer; hour
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 25 4.4.10. Turning off the device Press button to turn off. NOTE: A new ignition is possible after the OFF icon stops flashing. If the appliance is not to be used for some time, please close the gas supply valve in the gas pipe (...
Page 26 - Automatic Turn Down To Pilot; Hour No Communication Function; Automatic Shut Off
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 26 4.4.12. Automatic Turn Down To Pilot 3 Hour No Communication Function The valve will turn to pilot flame if there is no communication between handset and receiver for a 3 hour period. The fire will continue to function normall...
Page 27 - Touchpad; To Turn ON Appliance
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 27 4.5. Touchpad Depending on customers preferences GaLiO Corten Remote may be additionally operated Touch panel. Photo 10: Touch panel To Turn ON Appliance • Press ON-OFF button (see Photo 10) until two short beeps confirm the s...
Page 28 - TESTING; Checking for gas leaks.; If the problem happens again please contact the dealer.; Checking the flame appearance.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 28 5. TESTING WARNING!!! NEVER TURN ON THE DEVICE IF THE CHARACTERISTIC SMELL OF GAS IS PERCEPTIBLE. If you smell gas during the operation of the fireplace turn off the device immediately and cut off the gas supply from the gas c...
Page 29 - MAINTENANCE AND UPKEEP; Testing and cleaning; Please check and clean as necessary:; Glass guard cleaning
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 29 6. MAINTENANCE AND UPKEEP We recommend cleaning the pilot flame and the main burner unit before the device is started again and after long intervals of inactivity. 6.1. Testing and cleaning Please check and clean as necessary:...
Page 30 - TROUBLESHOOTING
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 30 7. TROUBLESHOOTING Warning! Installation, upkeep and service need to be conducted by a qualified professional with appropriate qualification, an appropriate company or the gas supplier. PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION...
Page 32 - PRESSURE ADJUSTMENT
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 32 8. PRESSURE ADJUSTMENT Do not attempt to remove screws from the top of gas valve. Do not change any adjustments marked with tamper indicating paint. Motor knob is not to be removed.
Page 33 - Pilot Flame Adjustment; to 1⁄2ʺ of the thermocouple
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 33 • Pilot Flame Adjustment The pilot flow adjustment is preset to maximum at the factory. The pilot flame should envelope ⅜ʺ to ½ʺ of the thermocouple o The adjustment screw can be reached through a hole in the MANUAL knob (see ...
Page 34 - Minimum rate Adjustment
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 34 o Turn MANUAL knob and main valve knob to the ON position. o Turn pressure regulator adjustment screw to set required burner pressure (high fire). Pressure is increased by turning clockwise (pressure regulator models), or decr...
Page 35 - natural gas and vice versa; Pressure reading; Unscrew gas valve box cover using cross screwdriver.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 35 o Turn minimum rate adjustment screw to set required burner pressure (minimum fire). Pressure is increased by turning clockwise (pressure regulator models), or decreased by turning counterclockwise: LPG 0.62kPa, NG 0.37kPa War...
Page 37 - Put on gas valve cover and screw it back.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 37 o Screw tightly the screw on the test tap o Turn on the device and check if screw is sealed using gas detector, foam or other method. o Put on gas valve cover and screw it back.
Page 38 - ELECTRICAL DIAGRAMS
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 38 9. ELECTRICAL DIAGRAMS
Page 39 - TECHNICAL SPECIFICATION
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 39 10. TECHNICAL SPECIFICATION
Page 40 - MANUFACTURER’S CONTACT DETAILS; Poland
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 40 11. MANUFACTURER’S CONTACT DETAILS Company Name: Planika Sp. z o.o. Address: Bydgoska 38 86-061 Brzoza Poland Telephone: + 48 52 364 11 60 Fax: + 48 52 364 11 70
Page 41 - DISTRIBUTOR’S CONTACT DETAILS; Planika Australia
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#08 2020-03-20 41 12. DISTRIBUTOR’S CONTACT DETAILS Company Name: Planika Australia Address: 3/2 CYNAMIDE ST LAVERTON NTH, VIC 3016, AUSTRALIA Telephone: + 61 415 350 564 E-mail: [email protected]