Page 2 - Notice
A October 2002 4200-A2-GN20-10 Copyright © 2002 Paradyne Corporation.All rights reserved.Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated in...
Page 3 - Important Safety Instructions
4200-A2-GN20-10 October 2002 B Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or o...
Page 4 - EMI Notices
C October 2002 4200-A2-GN20-10 13. The equipment is intended for installation in a max. 65° C ambient temperature, in an environment that is free of dust and dirt. 14. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements ...
Page 5 - Japan
4200-A2-GN20-10 October 2002 D Japan Class A ITE This is a Class A product based on the standard of the Voluntary Control Council for interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, t...
Page 7 - Contents; About This Guide; iii; Installation; Installing the 4203 T1/E1 IMA Uplink DSL Cable Ferrite Choke . .
4200-A2-GN20-10 October 2002 i Contents About This Guide Document Purpose and Intended Audience . . . . . . . . . . . . . . . . . . . . iii New Features for This Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Document Summary . . . . . . . . . . . . . . . . . . . . . ....
Page 8 - ii
Contents ii October 2002 4200-A2-GN20-10 3 LEDs LED Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 LED Meanings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 4 Configuration Overview . . . . . . . ...
Page 9 - Document Purpose and Intended Audience
4200-A2-GN20-10 October 2002 iii About This Guide Document Purpose and Intended Audience This document is written for technicians who install the GranDSLAM 4200 ATM Stackable DSLAM. New Features for This Release This version of the document suppor ts GranDSLAM Release 2.0 and adds the following info...
Page 10 - iv; Document Summary; Related Product Documents; To order a paper copy of a Paradyne document:; Section; Document Number
About This Guide iv October 2002 4200-A2-GN20-10 Document Summary A master glossary of terms and acronyms used in Paradyne documents is available on the World Wide Web at www.paradyne.com. Select Library → Technical Manuals → Technical Glossary . Related Product Documents Documentation for the GranD...
Page 11 - Overview; The ReachDSLTM Model 4210 is interoperable with the Hotwire; GranDSLAM 4200 Models and Features
4200-A2-GN20-10 October 2002 1-1 1 Installation Overview The GranDSLAM™ 4200 is a family of stackable DSLAMs designed for installation in the Central Office (CO) environment or in a standalone configuration for small deployments. It is available with or without internal POTS splitters. The ReachDSL™...
Page 12 - Preparation; Installation Site; Descriptions
1. Installation 1-2 October 2002 4200-A2-GN20-10 Preparation Consider the following before installing the GranDSLAM 4200: Installation Site Your installation site should be well ventilated, clean, and free of environmental extremes. Installation Options The GranDSLAM 4200 may be: — Mounted w...
Page 13 - Cables Required; shows all the cables that may be required for your installation.; Cable Descriptions
1. Installation 4200-A2-GN20-10 October 2002 1-3 Cables Required Table 1-2 shows all the cables that may be required for your installation. Table 1-2. Cable Descriptions Connector Name Connector and Cable For Connecting . . . DSL PORTS 1–24 POTS 1–24 50-pin RJ21X Telco-type straight connector and 50...
Page 14 - Unpacking the Hardware; Table 1-3, Contents of Hardware Kit Shipped with the; in
1. Installation 1-4 October 2002 4200-A2-GN20-10 Unpacking the Hardware HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, howeve...
Page 16 - Mounting Configurations; Mounting Brackets; Equipment List; Installing the Brackets for Rack Mounting; Procedure
1. Installation 1-6 October 2002 4200-A2-GN20-10 Mounting Configurations Three basic installation configurations are available: Rack mount – see Installing the Brackets for Rack Mounting on page 1-6 and Installing the GranDSLAM 4200 Into a Rack on page 1-8. Wall mount – see Installing the GranDS...
Page 18 - Installing the GranDSLAM 4200 Into a Rack; Two types of mounting screws are provided. Use:; Grounding Lug; for more information.; To install the GranDSLAM 4200 into a rack:
1. Installation 1-8 October 2002 4200-A2-GN20-10 Installing the GranDSLAM 4200 Into a Rack Two types of mounting screws are provided. Use: #10-32 mounting screws for rails with threaded screw holes #12-24 mounting screws and self-retaining nuts for rails with unthreaded screw holes NOTE: Before ...
Page 19 - Installing the Uplink Module
1. Installation 4200-A2-GN20-10 October 2002 1-9 3. Inser t and tighten the screws in the top screw positions, then tighten the bottom screws. 4. Do not plug in the unit. Proceed to Installing the Uplink Module on page 1-13. 23-inch (584 mm) Nortel Rack Mount 1 12 13 24 DSL PORTS 1-2 4 POTS 1-24 4 8...
Page 20 - Installing the GranDSLAM 4200 on a Wall; To install the GranDSLAM 4200 on a wall:
1. Installation 1-10 October 2002 4200-A2-GN20-10 Installing the GranDSLAM 4200 on a Wall Wall mounting requires two wood screws suitable for the weight of the fully cabled unit. These are not included. Use at a minimum 1/4-inch (6 mm) diameter screws in 3/4-inch (19 mm ) plywood (not drywall). Proc...
Page 21 - Proceed to
1. Installation 4200-A2-GN20-10 October 2002 1-11 6. Install two wood screws (not provided) at the same height above the floor and 18.75 inches (476.25 mm ) apar t. Do not completely tighten the screws. Leave them so their heads are about 1/4 inch (6 mm) from the wall. 7. Hang the unit from the wood...
Page 22 - Installing the GranDSLAM 4200 on a Shelf or Desktop; Locate the rubber feet in the hardware kit provided with the unit.
1. Installation 1-12 October 2002 4200-A2-GN20-10 Installing the GranDSLAM 4200 on a Shelf or Desktop If the GranDSLAM 4200 will be placed on a shelf or desktop, install the provided rubber feet before putting the unit in position. Procedure To install the GranDSLAM 4200 on a shelf or desktop, as a ...
Page 23 - Cabling; To install the uplink module:
1. Installation 4200-A2-GN20-10 October 2002 1-13 Installing the Uplink Module Each GranDSLAM 4200 requires an uplink module for connection to the ATM network. If your uplink module was shipped separately from the GranDSLAM 4200, install the uplink module before you connect the unit to a power sourc...
Page 24 - Fasten the two screws provided with the uplink module.
1. Installation 1-14 October 2002 4200-A2-GN20-10 3. Slide the uplink module into the guide rails just inside the opening. Press the uplink module firmly into place until it is fully seated and the faceplate of the uplink module is flush against the faceplate of the GranDSLAM 4200. 4. Fasten the two...
Page 25 - Cabling Overview
4200-A2-GN20-10 October 2002 2-1 2 Cabling Cabling Overview The GranDSLAM 4200 has a large variety of possible cabling configurations. This chapter describes all possible connections, not all of which are required: DSL Por ts on page 2-2 4201 T1 Uplink Module Connector on page 2-3 4202 E1 Upli...
Page 26 - DSL Ports
2. Cabling 2-2 October 2002 4200-A2-GN20-10 DSL Ports The GranDSLAM 4200 DSL connector suppor ts the tip and ring connections of up to 24 DSL ports over a 50-position cable. A POTS (plain old telephone service) splitter connector is also provided. If your model does not contain the integrated POTS s...
Page 27 - Uplink Module Connectors; The following types of uplink modules are available for the unit:; To connect to the 4201 T1 Uplink Module:
2. Cabling 4200-A2-GN20-10 October 2002 2-3 Uplink Module Connectors The following types of uplink modules are available for the unit: Model 4201 T1 Uplink Module Model 4202 E1 Uplink Module Model 4203 T1/E1 IMA Uplink Module 4201 T1 Uplink Module Connector The 4201 T1 Uplink Module has a sing...
Page 28 - connector is the default.; Determine the interface type, and procure the appropriate cable.; Do not plug cables into both the 120
2. Cabling 2-4 October 2002 4200-A2-GN20-10 4202 E1 Uplink Module Connectors The 4202 E1 Uplink Module has two connectors, only one of which may be used at a time: 120 Ω connector – A balanced RJ48C, 8-pin, unkeyed, unshielded connector. The 120 Ω connector is the default. 75 Ω connector – An un...
Page 29 - Change the connector default to 75; such as a multiplexer.
2. Cabling 4200-A2-GN20-10 October 2002 2-5 3. Connect the other end of the cable to the appropriate network equipment such as a multiplexer. Procedure To connect to the 4202 E1 Uplink Module 75 Ω connector: 1. Determine the interface type, and procure the appropriate coaxial cable. 2. Change the co...
Page 30 - 203 T1/E1 IMA Uplink Module Port Connectors; To connect to the 4203 T1/E1 IMA Uplink Module:; for more information on subtending and TL1 commands.; Installing the 4203 T1/E1 IMA Uplink DSL
2. Cabling 2-6 October 2002 4200-A2-GN20-10 4203 T1/E1 IMA Uplink Module Port Connectors The 4203 T1/E1 IMA Uplink Module suppor ts eight operational T1/E1 por ts, each with an RJ48C, 8-pin, unkeyed, shielded connector. The 4203 uplink module can be used to aggregate up to four other GranDSLAM 4200 ...
Page 31 - such as an ATM switch.
2. Cabling 4200-A2-GN20-10 October 2002 2-7 4. Connect the other end of the cable(s) to the appropriate network equipment such as an ATM switch. Or, if this is the aggregation unit in a stack, connect to one of the following connectors on a basic unit in the stack: — 100 Ω connector on a 4201 T1 Mod...
Page 32 - Installing the 4203 T1/E1 IMA Uplink DSL Cable Ferrite Choke; connector on the uplink module as possible.
2. Cabling 2-8 October 2002 4200-A2-GN20-10 Installing the 4203 T1/E1 IMA Uplink DSL Cable Ferrite Choke The 4203 T1/E1 IMA Uplink is shipped with a ferrite choke that must be installed on the DSL cable(s). One choke can accommodate 1–8 cables. Procedure To install the ferrite choke onto the DSL cab...
Page 33 - Management Port; To use the MGMT por t:
2. Cabling 4200-A2-GN20-10 October 2002 2-9 Management Port The MGMT (management) port can be used to connect the GranDSLAM 4200 to a network management system using a 10BaseT or 100BaseT LAN. The MGMT por t is isolated and no user data is accessible over it. A straight-through cable is used. Proced...
Page 34 - Console Port; To connect a terminal or PC to the CONSOLE por t:
2. Cabling 2-10 October 2002 4200-A2-GN20-10 Console Port The CONSOLE port normally serves as the primar y user interface with the GranDSLAM 4200 during installation. You can connect a terminal or PC directly to the CONSOLE port using a DTE cable (see procedure below). You can also use the CONSOLE p...
Page 35 - To connect a modem to the CONSOLE port:
2. Cabling 4200-A2-GN20-10 October 2002 2-11 Procedure To connect a modem to the CONSOLE port: 1. Determine and procure the proper DCE cable type. The CONSOLE port requires a DB9 plug connector. The other connector depends on the serial por t on your modem, but normally a DB25 plug is required. 2. C...
Page 36 - Alarm Interface; The alarm interface differs, depending on GranDSLAM 4200 model.; Connection Example
2. Cabling 2-12 October 2002 4200-A2-GN20-10 Alarm Interface The alarm interface differs, depending on GranDSLAM 4200 model. Model 4210 – The ALARM interface for the Model 4210 consists of three contacts that provide access to to the alarm relays that can be used to set off Major and Minor physica...
Page 37 - To connect the ALARM interface:
2. Cabling 4200-A2-GN20-10 October 2002 2-13 Procedure To connect the ALARM interface: 1. Strip the tips of the alarm source wires (about 1/2 inch or 12.7 mm in length). 2. For Model 4210, inser t the wires into the 3-position plug. Securely fasten each wire by tightening the screw above it. For Mod...
Page 39 - To connect the unit to a ground:
2. Cabling 4200-A2-GN20-10 October 2002 2-15 Grounding Lug Procedure To connect the unit to a ground: 1. Strip back the insulation approximately 5/16 of an inch (8 mm) on 14 AWG copper ground wire. 2. Loosen the screw on the grounding lug located on the side panel near the front of the unit. 3. Inse...
Page 40 - Power Connector; before inserting the wire into the 2-position plug.
2. Cabling 2-16 October 2002 4200-A2-GN20-10 Power Connector The GranDSLAM 4200 is powered by a – 48 VDC source providing – 40.5 to – 57.0 VDC. Dual power feeds are provided (A and B) for redundancy. The terminal block accepts 16 or 18 AWG wire. The 4200 GranDSLAM contains two external fuses, each w...
Page 41 - rail with a cable tie.; LEDs
2. Cabling 4200-A2-GN20-10 October 2002 2-17 3. Inser t the plug into either the A or B power input terminal on the front panel of the GranDSLAM 4200. 4. If the unit is in a rack, dress the power cables to the left and fasten them to the rail with a cable tie. 5. Power on the GranDSLAM 4200. 6. Make...
Page 43 - LED Locations; Front Panel LEDs
4200-A2-GN20-10 October 2002 3-1 3 LEDs LED Locations The locations of the System and DSL Port LEDs on the front panel of the GranDSLAM 4200 are shown in Figure 3-1, Front Panel LEDs . Figure 3-1. Front Panel LEDs 1 12 13 24 DSL POR TS 1-24 POTS 1-24 4 8 16 20 POWER A ALARM RTN -48V DC BITS MGMT CON...
Page 44 - LED Meanings
3. LEDs 3-2 October 2002 4200-A2-GN20-10 LED Meanings When power is first applied to the unit, it performs a power-on self-test. When this test is successfully completed, the Status LED blinks. The meaning of all the LEDs is shown in Table 3-1, Front Panel LEDs . Table 3-1. Front Panel LEDs LED Colo...
Page 45 - Configuration; Managing out of band through the Ethernet port.; GranDSLAM 4200 ATM Stackable DSLAM; Conventions Used; Courier
4200-A2-GN20-10 October 2002 4-1 4 Configuration Overview The GranDSLAM 4200 is designed to require minimal configuration before it can be accessed by a Network Operations Center (NOC). Initial configuration can be performed using the Command Line Interface (CLI). The CLI is available from a termina...
Page 46 - Using the CLI; GranDSLAM 4200 ATM Stackable
4. Configuration 4-2 October 2002 4200-A2-GN20-10 Using the CLI The GranDSLAM 4200 uses Transaction Language No. 1 (TL1) language for CLI commands and messages. These commands and messages are used to configure and maintain the system. See the GranDSLAM 4200 ATM Stackable DSLAM User’s Guide for deta...
Page 47 - Command query. You can obtain help with CLI commands by typing a; the CLI lists all the possible RTRV commands.; GranDSLAM 4200 Turn-up Procedure; Out-of-Band Management – Operates over the Ethernet interface.
4. Configuration 4200-A2-GN20-10 October 2002 4-3 Command query. You can obtain help with CLI commands by typing a ? (question mark). A question mark alone lists all commands. For example, if you enter: RTRV ? the CLI lists all the possible RTRV commands. Command history. Pressing the Up Arrow k...
Page 48 - Turn-up Procedure for Inband Management; To turn up the GranDSLAM 4200 using inband management:; Set the ATM1 physical address using the ENT-VCL TL1; To turn up the GranDSLAM 4200 using the Ethernet interface:
4. Configuration 4-4 October 2002 4200-A2-GN20-10 Turn-up Procedure for Inband Management Procedure To turn up the GranDSLAM 4200 using inband management: 1. Manual Mode: At the unit, configure the IP address, net mask, and next-hop router. DHCP Mode: Set the ATM1 physical address using the ENT-VCL ...
Page 49 - Configuring the Unit for Operation; Change the SNMP community strings using the EMS.
4. Configuration 4200-A2-GN20-10 October 2002 4-5 6. Change the time, if necessary. The Simple Network Time Protocol (SNTP), which maintains the unit’s clock, defaults to enabled. However, you can change the time offset from Coordinated Universal Time (UTC) using the TZOFFSET parameter of the SET-NE...
Page 51 - Connectors and Pin Assignments; The following sections provide pin assignments for:
4200-A2-GN20-10 October 2002 A-1 A Connectors and Pin Assignments Overview The following sections provide pin assignments for: Management Por t Connector on page A-3 DSL Por ts and POTS Splitter Connectors on page A-2 Management Por t Connector on page A-3 Console Por t Connector on page A-3...
Page 52 - DSL Ports and POTS Splitter Connectors; and 50 are not; DSL Connector Pinouts
A. Connectors and Pin Assignments A-2 October 2002 4200-A2-GN20-10 DSL Ports and POTS Splitter Connectors The 50-pin RJ21X Telco connector labeled DSL Por ts 1–24 provides the 2-wire loop interface from each DSL port to the demarcation point. (The Canadian designation for this connector is CA21A.) T...
Page 54 - Model 4210 ALARM/BITS Connector
A. Connectors and Pin Assignments A-4 October 2002 4200-A2-GN20-10 Model 4210 ALARM/BITS Connector The alarm relay reports major alarms through the ALARM connector (top row of contacts on the ALARM/BITS terminal block) on the front panel of the GranDSLAM Model 4210. The BITS connector (bottom row of...
Page 55 - connector are shown in; Connector
A. Connectors and Pin Assignments 4200-A2-GN20-10 October 2002 A-5 4201 T1 Uplink Module Connector The 4201 T1 Uplink Module 100 Ω connector is a single, RJ48C, unkeyed, shielded, 8-pin modular jack. The shield is connected to ground via the module. Pin assignments for the 100 Ω connector are shown ...
Page 56 - 202 E1 Uplink Module Connectors
A. Connectors and Pin Assignments A-6 October 2002 4200-A2-GN20-10 4202 E1 Uplink Module Connectors The 4202 E1 Uplink Module has two types of connectors, only one of which may be used at a time: 120 Ω Connector 75 Ω Connector TX/RX Connectors 120 Ω Connector The 120 Ω connector is a single, RJ4...
Page 57 - Signal
A. Connectors and Pin Assignments 4200-A2-GN20-10 October 2002 A-7 4203 T1/E1 IMA Uplink Module Port Connectors The 4203 T1/E1 IMA Uplink Module por t connectors consist of eight RJ48C, unkeyed, shielded, 8-pin modular jacks. The shield is connected to ground via the module. Pin assignments for the ...
Page 59 - Description
4200-A2-GN20-10 October 2002 B-1 B Equipment List Table B-1. GranDSLAM 4200 Equipment List (1 of 4) Description Model Number GranDSLAM 4200 (24-Port) ReachDSL with 4201 T1 Uplink Module, without POTS Splitter, with U.S. defaults Includes GranDSLAM 4200, 19- and 23-inch mounting brackets and hardware...
Page 63 - Technical Specifications; Technical specifications are subject to change without notice.; GranDSLAM 4200 Technical Specifications (1 of 2)
4200-A2-GN20-10 October 2002 C-1 C Technical Specifications Technical specifications are subject to change without notice. Table C-1. GranDSLAM 4200 Technical Specifications (1 of 2) Specifications Criteria Cooling and Air Handling Each GranDSLAM 4200 is independently cooled with integral fans and d...
Page 65 - Index; Numerics
4200-A2-GN20-10 October 2002 IN-1 Index Numerics 100-ohm port description, 1-3120-ohm port description, 1-375-ohm port description, 1-3 A administrator, login, 4-3aggregation unit, 2-7ALARM port cabling, 2-12description, 1-3pin assignments, A-3 audience for this document, iii B brackets installation...