Page 2 - Copyright 2005 Paradyne Corporation.; Document Feedback
A March 2005 2600-A2-GN20-40 Copyright 2005 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into...
Page 3 - Software and Firmware License Agreement
2600-A2-GN20-40 March 2005 B Software and Firmware License Agreement The terms and conditions of this License Agreement (the “Agreement”) will apply to the software and/or firmware (individually or collectively the “Software”) incorporated into the Paradyne product (the “Product”) purchased by you a...
Page 4 - Important Safety Instructions
C March 2005 2600-A2-GN20-40 Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. This product is intended to be used with a 3-wire grounding type plug — a plug that has a grounding pin. This is a safety feature. Eq...
Page 6 - Japan
E March 2005 2600-A2-GN20-40 Japan Class A ITE This is a Class A product based on the standard of the Voluntary Control Council for interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the...
Page 7 - Contents; About This Guide
2600-A2-GN20-40 March 2005 i Contents Software and Firmware License Agreement . . . . . . . . . . . . . . . . . . . . B About This Guide Document Purpose and Intended Audience . . . . . . . . . . . . . . . . . . . . iii Document Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 8 - ii; Configuration
Contents ii March 2005 2600-A2-GN20-40 Connecting to Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12 3 LEDs LED Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 LED Meanings . . . . . . . . . . . . . . . ...
Page 9 - iii; Document Purpose and Intended Audience; Section
2600-A2-GN20-40 March 2005 iii About This Guide Document Purpose and Intended Audience This document is written for technicians who install the BitStorm ® 2600 IP DSLAM. Document Summary A master glossary of terms and acronyms used in Paradyne documents is available on the World Wide Web at www.para...
Page 10 - iv; Related Product Documents; Document Number
About This Guide iv March 2005 2600-A2-GN20-40 Related Product Documents Documentation for the BitStorm 2600 IP DSLAM is available on the World Wide Web at www.paradyne.com . Select Support → Technical Manuals. To order a paper copy of a Paradyne document, or to talk to a sales representative, pleas...
Page 11 - Installation; Overview
2600-A2-GN20-40 March 2005 1-1 1 Installation Overview The BitStorm ® 2600 is a family of stackable IP DSLAMs designed for installation in a Central Office (CO), multi-tenant unit (MTU), multi-dwelling unit (MDU), or remote terminal environment. The BitStorm 2600 is available with or without interna...
Page 12 - Preparation; Installation Site; Power
1. Installation 1-2 March 2005 2600-A2-GN20-40 Up to eight BitStorm 2600 units can be logically stacked, with aggregation for up to 192 ports of DSL traffic. ReachDSL, ADSL, and SHDSL units can be included in the same stack. Preparation Consider the following before installing the BitStorm 2600 IP D...
Page 13 - Cables Required; Connector Name
1. Installation 2600-A2-GN20-40 March 2005 1-3 Cables Required Table 1-1 shows all the cables that may be required for your installation. Table 1-1. Cable Descriptions Connector Name Connector and Cable For Connecting . . . DSL PORTS 1–24 POTS 1–24 50-pin RJ21X Telco-type straight connector and 50-w...
Page 14 - Unpacking the Hardware; HANDLING PRECAUTIONS FOR; Package Contents
1. Installation 1-4 March 2005 2600-A2-GN20-40 Unpacking the Hardware HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however,...
Page 16 - Mounting Configurations; Mounting Brackets; Installing the Brackets for Rack Mounting; Procedure
1. Installation 1-6 March 2005 2600-A2-GN20-40 Mounting Configurations Three basic installation configurations are available: Rack mount – see Installing the Brackets for Rack Mounting on page 1-6 and Installing the BitStorm 2600 Into a Rack on page 1-8. Wall mount – see Installing the BitStorm ...
Page 18 - Installing the BitStorm 2600 Into a Rack
1. Installation 1-8 March 2005 2600-A2-GN20-40 Installing the BitStorm 2600 Into a Rack Two types of mounting screws are provided. Use: #10-32 mounting screws for rails with threaded screw holes #12-24 mounting screws and self-retaining nuts for rails with unthreaded screw holes Procedure To ins...
Page 20 - Installing the BitStorm 2600 on a Wall
1. Installation 1-10 March 2005 2600-A2-GN20-40 Installing the BitStorm 2600 on a Wall Wall mounting requires two wood screws suitable for the weight of the fully cabled unit. These are not included. Use at a minimum 1/4-inch (6 mm) diameter screws in 3/4-inch (19 mm ) plywood (not drywall). Procedu...
Page 22 - Installing the BitStorm 2600 on a Shelf or Desktop
1. Installation 1-12 March 2005 2600-A2-GN20-40 Installing the BitStorm 2600 on a Shelf or Desktop If the BitStorm 2600 will be placed on a shelf or desktop, install the provided rubber feet before putting the unit in position. Procedure To install the BitStorm 2600 on a shelf or desktop, as a stand...
Page 23 - Cabling; Cabling Overview
2600-A2-GN20-40 March 2005 2-1 2 Cabling Cabling Overview The BitStorm 2600 has a large variety of possible cabling configurations. This chapter describes all possible connections, not all of which are required: DSL Ports on page 2-2 GigE Uplink (Port 3) on page 2-3 10/100BaseT Uplink (Port 2)...
Page 24 - DSL Ports
2. Cabling 2-2 March 2005 2600-A2-GN20-40 DSL Ports The BitStorm 2600 DSL connector supports the tip and ring connections of up to 24 DSL ports over a 50-position cable. A POTS (plain old telephone service) splitter connector is also provided, for CO applications only. The internal splitter includes...
Page 25 - For a wire connection
2. Cabling 2600-A2-GN20-40 March 2005 2-3 4. Tighten the cable tie around the connector and trim the excess. 5. If you use an internal POTS splitter, repeat Step 1 through Step 4 , substituting POTS 1–24 for DSL PORTS 1–24. 6. Secure the cables as required for strain relief. GigE Uplink (Port 3) Por...
Page 26 - configure uplink
2. Cabling 2-4 March 2005 2600-A2-GN20-40 2. Connect the other end of the uplink cable to the uplink interface, such as an Ethernet switch. 3. Port 3 (eth3) is the default uplink. If you have changed the default, use the configure uplink CLI command or the Configuration / Uplink screen of the web in...
Page 27 - T1 or E1 Uplink
2. Cabling 2600-A2-GN20-40 March 2005 2-5 T1 or E1 Uplink Models that support T1 or E1 have eight ports that can be used in any combination to provide PPP or MLPPP uplinks. Procedure To use T1 or E1 uplinks: 1. Use the CLI or web interface to configure PPP or MLPPP paths. 2. Connect an 8-position mo...
Page 29 - Management Port
2. Cabling 2600-A2-GN20-40 March 2005 2-7 Management Port Port 1 can be used to connect the BitStorm 2600 to a network management system using a 10BaseT or 100BaseT LAN. A straight-through cable can be used regardless of the destination interface, since the port automatically distinguishes between a...
Page 30 - Console Port; Connecting a Terminal or PC to the Console Port
2. Cabling 2-8 March 2005 2600-A2-GN20-40 Console Port The CONSOLE port normally serves as the primary user interface with the BitStorm 2600 during installation. You can connect a terminal or PC directly to the CONSOLE port using a DTE cable (see procedure below). You can also use the CONSOLE port t...
Page 31 - Connecting a Modem to the Console Port
2. Cabling 2600-A2-GN20-40 March 2005 2-9 Connecting a Modem to the Console Port Procedure To connect a modem to the CONSOLE port: 1. Determine and procure the proper DCE cable type for your modem. The CONSOLE port requires a DB9 plug connector. The other connector depends on the serial port on your...
Page 32 - Alarm Interface
2. Cabling 2-10 March 2005 2600-A2-GN20-40 Alarm Interface The ALARM interface consists of five contacts. Three of the contacts provide access to alarm relays that that can be used to set off Major and Minor physical alarms. The other two contacts provide access to a sense circuit that can be used t...
Page 33 - Ground
2. Cabling 2600-A2-GN20-40 March 2005 2-11 Ground Procedure To connect the unit to a ground: 1. Crimp a ring terminal onto the stripped end of 14 AWG or heavier copper ground wire. 2. Remove the screw marked by the ground symbol ( ) at the right side of the front panel. 3. Fasten the ring terminal t...
Page 34 - Connecting to Power
2. Cabling 2-12 March 2005 2600-A2-GN20-40 Connecting to Power The BitStorm 2600 can be powered by any AC power source supplying 90–265 VAC at 47–63 Hz. Procedure To connect the BitStorm 2600 to a power source: 1. Insert the supplied power cord into the power socket on the back of the unit. 2. If th...
Page 35 - LEDs; LED Locations
2600-A2-GN20-40 March 2005 3-1 3 LEDs LED Locations The locations of the System and DSL Port LEDs on the front panel of the BitStorm 2600 are shown in Figure 3-1, Front Panel LEDs (GigE Uplink) . Figure 3-1. Front Panel LEDs (GigE Uplink) Figure 3-2. Front Panel LEDs (T1/E1 Uplink) 03-17454 PORT1-10...
Page 36 - LED Meanings; LED
3. LEDs 3-2 March 2005 2600-A2-GN20-40 LED Meanings When power is first applied to the unit, it performs a power-on self-test. When this test is successfully completed, the Status LED blinks. The meaning of all the LEDs is shown in Table 3-1, Front Panel LEDs . Table 3-1. Front Panel LEDs LED Color ...
Page 37 - Configuration
2600-A2-GN20-40 March 2005 4-1 4 Configuration Overview The BitStorm 2600 is designed to require minimal configuration before it can be accessed by a Network Operations Center (NOC). When the BitStorm 2600 is first powered up it is a fully functional bridge, and all DSL ports are set to their maximu...
Page 38 - Using the CLI; Configure Management Default Gateway Address; configure management default gateway; Command
4. Configuration 4-2 March 2005 2600-A2-GN20-40 Using the CLI A command line interface (CLI) can be used to configure and monitor the unit. The CLI is available from a PC or terminal connected to the Console port, or from a Telnet session with the device. The following commands are available: Descri...
Page 39 - Configure Management Inband Address; configure management inband address; configure management out-of-band address
4. Configuration 2600-A2-GN20-40 March 2005 4-3 Configure Management Inband Address The configure management inband address command specifies the IP address of the unit. Configure Management Out-of-Band Address The configure management out-of-band address command specifies the IP address of the unit...
Page 40 - BitStorm 2600 Startup Procedure; Login; admin; Management Modes
4. Configuration 4-4 March 2005 2600-A2-GN20-40 BitStorm 2600 Startup Procedure You can initialize your BitStorm 2600 via a PC or terminal connected to the unit’s CONSOLE port. Then, using a series of CLI commands, GrandVIEW EMS or another Element Management System, or the web interface, you can con...
Page 41 - Startup Procedure for Inband Management; configure uplink eth3; Startup Procedure for Out-of-Band Management; configure
4. Configuration 2600-A2-GN20-40 March 2005 4-5 Startup Procedure for Inband Management With inband management, the BitStorm 2600 is managed using the uplink port. Procedure To start up the BitStorm 2600 using inband management: 1. Specify the uplink port using the configure uplink command. It must ...
Page 42 - Using the Web Interface
4. Configuration 4-6 March 2005 2600-A2-GN20-40 Using the Web Interface To access the web interface: Procedure 1. Open your web browser. (Internet Explorer Version 6 or above is recommended.) 2. Type http:// and the IP address of the BitStorm 2600 into the Address field of your browser window. For e...
Page 45 - Connectors and Pin Assignments
2600-A2-GN20-40 March 2005 A-1 A Connectors and Pin Assignments Overview The following sections provide pin assignments for: DSL Ports and POTS Splitter Connectors on page A-2 Port 1 and Port 2 10/100BaseT Connectors on page A-3 Port 3 1000BaseT Connector on page A-3 Port 3 GigE SFP Connecto...
Page 46 - DSL Ports and POTS Splitter Connectors; DSL Port
A. Connectors and Pin Assignments A-2 March 2005 2600-A2-GN20-40 DSL Ports and POTS Splitter Connectors The 50-pin RJ21X Telco connector labeled DSL Ports 1–24 provides the 2-wire loop interface from each DSL port to the MDF for CO applications, or the in-building wiring for customer premises applic...
Page 47 - Signal
A. Connectors and Pin Assignments 2600-A2-GN20-40 March 2005 A-3 Port 1 and Port 2 10/100BaseT Connectors Port 1 and Port 2 are 8-pin unkeyed modular jacks for a 10/100Base interface. Port 3 1000BaseT Connector Port 3’s 1000BaseT interface is an 8-pin unkeyed modular jack. Table A-2. Port 1 and Port...
Page 48 - Port 3 GigE SFP Connector
A. Connectors and Pin Assignments A-4 March 2005 2600-A2-GN20-40 Port 3 GigE SFP Connector Port 3’s GigE interface is a standard SFP socket. Table A-4. Port 3 GigE Connector Signal Pin VeeT 1 TXFault 2 TXDisable 3 MOD-DEF(2) – I2C_DATA 4 MOD-DEF(1) – I2C_CLK 5 MOD-DEF(0) – SFP_PRESENT_L 6 Rate Selec...
Page 50 - ALARM Connector
A. Connectors and Pin Assignments A-6 March 2005 2600-A2-GN20-40 ALARM Connector The alarm relay reports major alarms through the ALARM connector. The alarm contacts are closed during normal operation. They open in response to loss of power, hardware failure, or other alarm conditions. The maximum r...
Page 51 - DSL Type
2600-A2-GN20-40 March 2005 B-1 B Equipment List All BitStorm 2600 models include the BitStorm 2600, 19- and 23-inch mounting brackets and hardware, and an Installation Guide. Table B-1. BitStorm 2600 Model List (1 of 2) Model Number DSL Ports DSL Type Splitters Power Cord Compatibility Other Feature...
Page 53 - Technical Specifications; Specifications
2600-A2-GN20-40 March 2005 C-1 C Technical Specifications Technical specifications are subject to change without notice. Table C-1. BitStorm 2600 Technical Specifications (1 of 2) Specifications Criteria Alarm Contacts Maximum Rated Load 30 VDC: 1.0 Amp 60 VDC: 0.6 Amp 60 VAC: 0.6 Amp Cooling ...
Page 55 - Index; Numerics
2600-A2-GN20-40 March 2005 IN-1 Index Numerics 10/100BaseT pinouts, A-31000BaseT pinouts, A-3 A AC power, 2-12Activity LEDs, 3-2administrator, login, 4-4Alarm connector pinouts, A-6LED, 3-2port cabling, 2-10port connectors, A-6port description, 1-3 audience for this document, iiiautosensing, 2-4, 2-...