Page 2 - October; Wiring the PEM; PEM with Internal Power Terminals; PEM; PEM

2 October 2004 8820-A2-GZ45-20 Wiring the PEM HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static cont...

Page 3 - You need a Phillips screwdriver to remove the PEM from the BAC.; Removing the PEM from the BAC; Procedure; Ensure that the power is disconnected at the source.; Ring Tongue

8820-A2-GZ45-20 October 2004 3 WARNINGS: „ It is recommended that the following procedure be performed by a qualified electrician. „ The 48 VDC or 60 VDC power must be disconnected at its source before attempting to connect wiring to the PEM. Do not remove wired PEMs without first disconnecting the ...

Page 4 - Installing the Replacement Power Entry Module in the 8820 BAC; Copyright

4 October 2004 8820-A2-GZ45-20 Installing the Replacement Power Entry Module in the 8820 BAC Procedure 1. Apply the supplied compression–type ring tongue terminals to the #8 AWG power wires. Use the Molex Magna Crimp Hand Tool (Part No. MCT–8200). 2. Fasten the #8 AWG wires, with their ring tongue t...