Page 2 - Notice; Document Feedback
A July 2004 4821-A2-GN21-10 Copyright © 2004 Paradyne Corporation.All rights reserved.Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into ...
Page 3 - Software and Firmware License Agreement
4821-A2-GN21-10 July 2004 B Software and Firmware License Agreement The terms and conditions of this License Agreement (the “Agreement”) will apply to the software and/or firmware (individually or collectively the “Software”) incorporated into the Paradyne product (the “Product”) purchased by you an...
Page 4 - Important Safety Instructions
C July 2004 4821-A2-GN21-10 7. The rights granted under this Agreement may not be assigned, sublicensed or otherwise transferred by the Licensee to any third party without the prior written consent of Paradyne. 8. This Agreement and the license granted under this Agreement shall be terminated in the...
Page 5 - EMI Notices
4821-A2-GN21-10 July 2004 D 10. CLASS 1 LASER PRODUCT : This product has provisions for the customer to install a Class 1 laser transciever, which provides optical coupling to the telecommunication network. Once a Class 1 laser product is installed, the equipment is to be considered to be a Class 1 ...
Page 6 - Notices to Users of the Canadian Telephone Network; Japan
E July 2004 4821-A2-GN21-10 Notices to Users of the Canadian Telephone Network NOTICE: This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation IC before the registration number signifies that regi...
Page 7 - Contents; About This Guide; Installation
4821-A2-GN21-10 July 2004 i Contents About This Guide Document Purpose and Intended Audience . . . . . . . . . . . . . . . . . . . . iii Document Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Related Product Documents . . . . . . . . . . . . . . . . . ...
Page 8 - ii; Configuration
Contents ii July 2004 4821-A2-GN21-10 4 Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Using the CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Configure Management Default Ga...
Page 9 - Document Purpose and Intended Audience; Section
4821-A2-GN21-10 July 2004 iii About This Guide Document Purpose and Intended Audience This document is written for technicians who install the BitStorm ® 4800 Express Model 4821-A2 IP DSLAM. Document Summary A master glossary of terms and acronyms used in Paradyne documents is available on the World...
Page 10 - iv; Related Product Documents; Document Number
About This Guide iv July 2004 4821-A2-GN21-10 Related Product Documents Documentation for the BitStorm 4800 Express IP DSLAM is available on the World Wide Web at www.paradyne.com . Select Support → Technical Manuals. To order a paper copy of a Paradyne document, or to talk to a sales representative...
Page 11 - Overview; BitStorm 4800 Express Models and Features
4821-A2-GN21-10 July 2004 1-1 1 Installation Overview The BitStorm ® 4800 Express is a stackable IP DSLAM designed for installation in a Central Office (CO), multi-tenant unit (MTU), or multi-dwelling unit (MDU) environment. The BitStorm 4800 Express is interoperable with the Hotwire 6381 ADSL/R mod...
Page 12 - Preparation; Installation Site; Power
1. Installation 1-2 July 2004 4821-A2-GN21-10 Preparation Consider the following before installing the BitStorm 4800 Express IP DSLAM: Installation Site Your installation site should be well ventilated, clean, and free of environmental extremes. Installation Options The BitStorm 4800 Express may...
Page 13 - Cables Required; Cable Descriptions
1. Installation 4821-A2-GN21-10 July 2004 1-3 Cables Required Table 1-2 shows all the cables that may be required for your installation. Table 1-2. Cable Descriptions Connector Name Connector and Cable For Connecting . . . DSL PORTS 1–24 DSL Ports 25–48 (if installed) 50-pin RJ21X Telco-type straigh...
Page 16 - Installing the Brackets for Rack Mounting; Procedure
1. Installation 1-6 July 2004 4821-A2-GN21-10 Mounting Configurations Three basic installation configurations are available: Rack mount – see Installing the Brackets for Rack Mounting on page 1-6 and Installing the BitStorm 4800 Express Into a Rack on page 1-8. Wall mount – see Installing the Bi...
Page 18 - Installing the BitStorm 4800 Express Into a Rack
1. Installation 1-8 July 2004 4821-A2-GN21-10 Installing the BitStorm 4800 Express Into a Rack Two types of mounting screws are provided. Use: #10-32 mounting screws for rails with threaded screw holes #12-24 mounting screws and self-retaining nuts for rails with unthreaded screw holes Procedure...
Page 20 - Installing the BitStorm 4800 Express on a Wall
1. Installation 1-10 July 2004 4821-A2-GN21-10 Installing the BitStorm 4800 Express on a Wall Wall mounting requires two wood screws suitable for the weight of the fully cabled unit. These are not included. Use at a minimum 1/4-inch (6 mm) diameter screws in 3/4-inch (19 mm ) plywood (not drywall). ...
Page 22 - Installing the BitStorm 4800 Express on a Shelf or Desktop
1. Installation 1-12 July 2004 4821-A2-GN21-10 Installing the BitStorm 4800 Express on a Shelf or Desktop If the BitStorm 4800 Express will be placed on a shelf or desktop, install the provided rubber feet before putting the unit in position. Procedure To install the BitStorm 4800 Express on a shelf...
Page 23 - Cabling; Cabling Overview
4821-A2-GN21-10 July 2004 2-1 2 Cabling Cabling Overview The BitStorm 4800 Express has a large variety of possible cabling configurations. This chapter describes all possible connections, not all of which are required: DSL Ports on page 2-2 10/100BaseT Uplink (Port 2) on page 2-3 Management Po...
Page 26 - Management Port
2. Cabling 2-4 July 2004 4821-A2-GN21-10 Management Port Port 1 can be used to connect the BitStorm 4800 Express to a network management system using a 10BaseT or 100BaseT LAN. A straight-through cable can be used regardless of the destination interface, since the port automatically distinguishes be...
Page 27 - Console Port; Connecting a Terminal or PC to the Console Port
2. Cabling 4821-A2-GN21-10 July 2004 2-5 Console Port The CONSOLE port normally serves as the primary user interface with the BitStorm 4800 Express during installation. You can connect a terminal or PC directly to the CONSOLE port using a DTE cable (see procedure below). You can also use the CONSOLE...
Page 28 - Connecting a Modem to the Console Port
2. Cabling 2-6 July 2004 4821-A2-GN21-10 Connecting a Modem to the Console Port Procedure To connect a modem to the CONSOLE port: 1. Determine and procure the proper DCE cable type for your modem. The CONSOLE port requires a DB9 plug connector. The other connector depends on the serial port on your ...
Page 29 - Ground
2. Cabling 4821-A2-GN21-10 July 2004 2-7 Ground Procedure To connect the unit to a ground: 1. Crimp a ring terminal onto the stripped end of 14 AWG or heavier copper ground wire. 2. Remove the screw marked by the ground symbol ( ) at the right side of the front panel. 3. Fasten the ring terminal to ...
Page 30 - Connecting to Power
2. Cabling 2-8 July 2004 4821-A2-GN21-10 Connecting to Power The BitStorm 4800 Express can be powered by any AC power source supplying 90–265 VAC at 47–63 Hz. Procedure To connect the BitStorm 4800 Express to a power source: 1. Insert the supplied power cord into the power socket on the back of the ...
Page 31 - LEDs; LED Locations; Front Panel LEDs
4821-A2-GN21-10 July 2004 3-1 3 LEDs LED Locations The locations of the System and DSL Port LEDs on the front panel of the BitStorm 4800 Express are shown in Figure 3-1, Front Panel LEDs . Figure 3-1. Front Panel LEDs 04-17533 Link LEDs Activity LEDS DSL Ports LEDs PORT1 10/100BT CONSOLE PORT2 10/10...
Page 32 - LED Meanings
3. LEDs 3-2 July 2004 4821-A2-GN21-10 LED Meanings When power is first applied to the unit, it performs a power-on self-test. When this test is successfully completed, the Status LED blinks. The meaning of all the LEDs is shown in Table 3-1, Front Panel LEDs . Table 3-1. Front Panel LEDs LED Color S...
Page 34 - Using the CLI; Configure Management Default Gateway Address; configure management default gateway; CLI Commands
4. Configuration 4-2 July 2004 4821-A2-GN21-10 Using the CLI A command line interface (CLI) can be used to configure and monitor the unit. The CLI is available from a PC or terminal connected to the Console port, or from a Telnet session with the device. The following commands are available: Descrip...
Page 35 - Configure Management Inband Address; configure management inband address; configure management out-of-band address
4. Configuration 4821-A2-GN21-10 July 2004 4-3 Configure Management Inband Address The configure management inband address command specifies the IP address of the unit. Configure Management Out-of-Band Address The configure management out-of-band address command specifies the IP address of the unit ...
Page 36 - BitStorm 4800 Express Startup Procedure; Login; admin; Management Modes
4. Configuration 4-4 July 2004 4821-A2-GN21-10 BitStorm 4800 Express Startup Procedure You can initialize your BitStorm 4800 Express via a PC or terminal connected to the unit’s CONSOLE port. Then, using a series of CLI commands, GrandVIEW EMS or another Element Management System, or the web interfa...
Page 37 - Startup Procedure for Inband Management; Startup Procedure for Out-of-Band Management; configure
4. Configuration 4821-A2-GN21-10 July 2004 4-5 Startup Procedure for Inband Management With inband management, the BitStorm 4800 Express is managed using the uplink port. Procedure To start up the BitStorm 4800 Express using inband management: 1. To avoid losing your connection when the IP address i...
Page 38 - Using the Web Interface
4. Configuration 4-6 July 2004 4821-A2-GN21-10 Using the Web Interface To access the web interface: Procedure 1. Open your web browser. (Internet Explorer Version 6 or above is recommended.) 2. Type http:// and the IP address of the BitStorm 4800 Express into the Address field of your browser window...
Page 41 - Connectors and Pin Assignments; BitStorm 4800 Express IP Front Panel
4821-A2-GN21-10 July 2004 A-1 A Connectors and Pin Assignments Overview The following sections provide pin assignments for: DSL Ports Connectors on page A-2 Port 1 and Port 2 10/100BaseT Connectors on page A-3 Console Port Connector on page A-4 Figure A-1. BitStorm 4800 Express IP Front Panel ...
Page 42 - DSL Ports Connectors; DSL Connector Pinouts
A. Connectors and Pin Assignments A-2 July 2004 4821-A2-GN21-10 DSL Ports Connectors The 50-pin RJ21X Telco connectors labeled DSL Por ts 1–24 and (on the 48-port model) DSL Ports 25–48 provide the 2-wire loop interface from each DSL port to the POTS splitter. The Canadian designation for this conne...
Page 44 - Console Port Connector
A. Connectors and Pin Assignments A-4 July 2004 4821-A2-GN21-10 Console Port Connector The CONSOLE port connector is a DB9 socket connector that suppor ts an EIA-232-E circuit as shown in Table A-3 . Table A-3. Console Port Connector RS-232 Signal Direction Pin Ground Out 1 Receive Data Out 2 Send D...
Page 45 - BitStorm 4800 Express Equipment List
4821-A2-GN21-10 July 2004 B-1 B Equipment List Table B-1. BitStorm 4800 Express Equipment List Description Model Number BitStorm 4800 Express Model 4821-A2 Command Line Interface Reference (paper copy) 4821-A2-GB21 BitStorm 4800 Express Model 4821-A2 SNMP Reference (paper copy) 4821-A2-GB22 BitStorm...
Page 47 - Technical Specifications; BitStorm 4800 Express Technical Specifications
4821-A2-GN21-10 July 2004 C-1 C Technical Specifications Technical specifications are subject to change without notice. Table C-1. BitStorm 4800 Express Technical Specifications Specifications Criteria Cooling and Air Handling Each BitStorm 4800 Express is independently cooled with integral fans and...
Page 49 - Index; Numerics
4821-A2-GN21-10 July 2004 IN-1 Index Numerics 10/100BaseT pinouts, A-3 A AC power, 2-8Activity LEDs, 3-2administrator, login, 4-4Alarm LED, 3-2audience for this document, iiiautosensing, 2-3–2-4 B BitStorm 4800 Express description, 1-1features, 1-1models, 1-1 brackets installation for rack mount, 1-...